background image

www.vicon-security.com

                                              

XX282-00-01

Surveyor® MKII Series  

Network Camera Domes

Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the 

operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed 

to be used in life-critical situations and must not be used for this purpose.

Vicon Industries Inc.

Tel: 631-952-2288  Fax: 631-951-2288 Toll Free: 800-645-9116 

24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 

Document Number: 8009-8282-00-01 

Product specifications subject to change without notice.  

Issued: 117

Copyright © 2017 Vicon Industries Inc. All rights reserved.

Installation Guide

Содержание Surveyor MKII Series XX282-00-01

Страница 1: ...escribed in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc Tel 631 952 2288 Fax 631 951 2288 Toll...

Страница 2: ...pter provides general information about Surveyor MKII Network Domes Refer to the end of this chapter for the organization of the rest of this manual The chapter consists of the following topics Topic...

Страница 3: ...omer interface board snaps down for easy access and the PCB provides removable terminal blocks for simple wiring connections The camera dome offers variable speed with stepping motors continuous rotat...

Страница 4: ...urveyor MKII Network Dome 2 Installation Describes how to install the Surveyor MKII Network Dome 3 Wiring and Operation Describes how to wire configure and operate the Surveyor MKII Network Dome 4 Mai...

Страница 5: ...Network Dome Chapter 2 Installation 2 This chapter provides installation information for the Surveyor MKII Network Dome The chapter consists of the following topics Topic Page Installation 2 5 Quick...

Страница 6: ...provide the best overall instructions for the installation and operation of the Surveyor MKII Network Dome The graphics and terminology used in this manual have been carefully selected to enable a cl...

Страница 7: ...perproof screws Refer to the Wiring section of this manual for details on using the supplied removable termination blocks Unpacking All Vicon equipment is tested and inspected before leaving the facto...

Страница 8: ...CPU It is designed for easy snap in installation into the housing The camera drive quickly and accurately positions the camera in 360 of pan angle and 90 of tilt angle An additional processor controll...

Страница 9: ...ra has a unique MAC address This information is essential in the camera configuration process Before starting installation make a record of the IP address and location of the camera The MAC address is...

Страница 10: ...Installation 2 9 Surveyor MKII HD Network Dome Quick Installation...

Страница 11: ...te coupling The pipe is a standard 1 5 inch NPT type and must be oriented vertically so the Surveyor MKII can effectively hang from the pipe The accessory kit contains the removable terminal blocks fo...

Страница 12: ...uration figure below 9 Remove terminal blocks from the accessory kit The 2 pin J2 is for power the 4 pin J11 is for control relay and the 8 pin is for alarms J12 10 Slide excess cable back up into the...

Страница 13: ...ge to the Surveyor MKII when installed into the housing 15 Push the camera drive straight up into the housing until it snaps into the housing Do not use excessive force In the event that it does not s...

Страница 14: ...nt version there are 6 screws 18 Proceed to the Operation section of this manual Accessing the SD Card The SD card slot is on the camera board right under the lens block To access the card remove the...

Страница 15: ...hapter will describe how to wire configure and operate the Surveyor MKII Network Dome The chapter consists of the following topics Topic Page Wiring the Surveyor MKII Network Dome 3 16 Typical Relay a...

Страница 16: ...pply The leads should be connected to Terminal Block 2 J2 The size of the two conductor cable depends on indoor outdoor application and cable distance as shown in the Table in the Technical Informatio...

Страница 17: ...of 2 3 4 5 or better Alarms 1 4 are electronic CMOS level type inputs that are driven by a dry contact type switch These signals are connected to terminal block J11 Each input has two states open and...

Страница 18: ...automatic momentary or manual and report status active inactive Refer to Web Browser manual for details as needed The relay output is an actual relay output dry contact which directly drives external...

Страница 19: ...top of the housing 2 Remove terminal blocks from the accessory kit The 2 pin is for power J2 the 4 pin is for relays J11 and the 8 pin is for alarms J12 3 Strip approximately 1 inch 25 mm of the cabl...

Страница 20: ...rm I O 1 J11 2 Ground J11 3 ALARM 2 Alarm I O 2 J11 4 Ground J11 5 ALARM 3 Alarm I O 3 J11 6 Ground J11 7 ALARM 4 Alarm I O 4 J11 8 Ground TERMINAL BLOCK COMM RELAY J12 J12 1 VSS Ground J12 2 C Relay...

Страница 21: ...r 3 Wiring Surveyor MKII HD Network Dome Communication Ports If using NTCIP protocol communicate to the Surveyor MKII using ports 3000 UDP or 3001 TCP If using ONVIF use port 8000 This is set in the w...

Страница 22: ...er provides Operation instructions Maintenance information cable recommendations and technical specifications for the Surveyor MKII Network Dome The chapter consists of the following topics Topic Page...

Страница 23: ...k with any Onvif compliant Video Management System VMS including Vicon s Valerus and ViconNet Refer to the documentation for those operating systems to setup the Surveyor MKII After the camera dome is...

Страница 24: ...the lower dome s interior remove it with clean dry pressurized air 3 If spots streaks or stains appear on the interior or exterior they may be removed with an approximate solution of 50 isopropyl alc...

Страница 25: ...peration Maintenance and Reference Surveyor MKII HD Network Dome Fuse Replacement The Surveyor MKII has one 3 A 60 V fuse on the CI board Be sure to use a fuse of the same value if it is necessary to...

Страница 26: ...tact Vicon Europe Ltd Unit 4 Nelson Industrial Park Hedge End Southampton SO30 2JH United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following i...

Страница 27: ...ed as a guideline when cables other than Belden are used Materials and construction must follow the guidelines above CABLE TYPE WIRE SIZE AWG INSULATION MATERIAL JACKET MATERIAL CATEGORY BANDWIDTH MHz...

Страница 28: ...work Dome 1 5 inch Pipe Designation The standard 1 5 inch pipe referred to in this manual has actual dimensions of Outside diameter 1 9 inches 48 3 mm Inside diameter 1 61 inches 40 9 mm Wall thicknes...

Страница 29: ...32 VAC use a Class 3 indoor dry or outdoor wet power supply Power Consumption 40 W including heater Fuse 3A 6V fuse on CI board resettable Maximum Operating Distance Refer to Maximum Power Distance th...

Страница 30: ...be associated with 14 events including preset 1 32 patterns autotours 1 4 scans autopan 1 4 Autotours 4 Privacy Mask 4 Alarm Capabilities 4 alarm inputs individually programmable Functional state ena...

Страница 31: ...relative non condensing Compliance International Protection IP Rating IP66 NEMA 4X NEMA TS2 2003 V02 06 Maximum Power Cable Distances Table Wire Size AWG Annealed Copper Wire Distance ft m Indoor Out...

Страница 32: ...without a lens extreme care should be used when mounting a lens on these products Damage to the product due to incorrectly mounted lenses will invalidate this limited hardware warranty Failure to com...

Страница 33: ...ied warranties are limited to the warranty period identified above Unless provided herein any statements or representations made by any other person or firm are void Except as provided in this written...

Страница 34: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...