background image

 iv

1.

  

Read these instructions.

2.

  

Keep these instructions.

3.

  

Heed all warnings.

4 .

 

Follow all instructions.

5.

  

Do not use this apparatus near water.

6.

  

Clean only with dry cloth.

7.

  

Do not block any ventilation openings. Install in accordance with the 

     manufacturer's instructions.

8.

  

Do not install near any heat sources such as radiators, heat registers, 

     stoves, or other apparatus (including amplifiers) that produce heat.

9.

  

Do not defeat the safety purpose of the polarized or grounding-type 

     plug. A polarized plug has two blades with one wider than the other. 

     A grounding type plug has two blades and a third grounding prong. 

     The wide blade or the third prong are provided for your safety. If the 

     provided plug does not fit into your outlet, consult an electrician for 

     replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly 

     at plugs, convenience receptacles, and the point where they exit from 

     the apparatus.

11. Only use attachments/accessories specified by the manufacturer.

12. Use only with the cart, stand, tripod, bracket, 

      or table specified by the manufacturer, 

      or sold with the apparatus. 

      When a cart is used,use caution when moving 

      the cart/apparatus combination to avoid injury 

      from tip-over.

13. Unplug this apparatus during lightning storms or when unused for 

       long periods of time.

14. Refer all servicing to qualified service personnel. Servicing is 

      required when the apparatus has been damaged in any way, such as

      power-supply cord or plug is damaged, liquid has been moisture, does 

      not operate normally, or has been dropped.

15. CAUTION  THESE SERVICING INSTRUCTIONS ARE FOR USE BY 

      QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE RISK 

      OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER 

      THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS 

      UNLESS YOU QRE QUALIFIED TO DO SO.

16. Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed 

      Class 2 power source only.

IMPORTANT SAFETY INSTRUCTIONS

Содержание Series 234-00-02

Страница 1: ...y as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge New Yor...

Страница 2: ...l before operating it any further Unplug the unit from the wall oulet if it is not going to be used for several days or more To disconnect the cord pull it out by the plug Never pull the cord itself A...

Страница 3: ...FERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN...

Страница 4: ...ugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table s...

Страница 5: ...ux Color 0 lux B W with LEDs on F1 2 30IRE Sensitivity shutter modes Auto electronic shutter 1 60 1 50 1 100 000 and manual electronic OSD On Screen Display Auto and manual white balance modes Digital...

Страница 6: ...supplying 10 Watts 4 RS 485 CONTROL GREEN RS485 BLUE RS485 5 Day Night External CONTROL 6 ALARM IN 7 ALARM OUT 8 GROUND How to Adjust ZOOM FOCUS Remote Controller Insert the din jack of remote control...

Страница 7: ...NS WATER INGRESS PREVENTION UNIT mm inches REMOTE CONTROL PORT CAP After using the Remote Control cable disconnect it and insert the Remote Control Port Cap Secure it tightly PACKAGE CONTENTS Caution...

Страница 8: ...h a remote control set up tool To connect the remote control to the camera first remove the Remote control port cap at the rear of the camera Use the 3 location holes around the base of the bracket to...

Страница 9: ...hin the camera Connect the BNC to a set up monitor to view the picture and On Screen Menus To Enter the menus press the button on the remote control To Navigate the menus move the button left Right Up...

Страница 10: ...ally impossible to see any details of the subjects Adjusts the iris so that a distinctive subject and the background are delivered at the same time HLC High Light Compensation When a high brightness s...

Страница 11: ...ature are sometimes observed when the devices are used under the influence of external factors or especially high temperatures The white pixel detection and compensation function can automatically det...

Страница 12: ...D EXPOSURE SHUTTER BRIGHTNESS AGC DWDR IRIS ADJ END WHITE BAL DAY NIGHT COLOR AUTO B W EXT RESET FACTORY LENS ADJ END ATW1 ATW2 AWC SET MANUAL BACKLIGHT OFF BLC HLC DPC COVER THE LENS ENTER KEY FOR ST...

Страница 13: ...BAL WHITE BAL MANUAL MODE WHITE BAL MANUAL COLOR TEMP OUTDOOR BLUE RED END The screen color can be adjusted by using the WHITE BALANCE function It compensates for deviations in the white color caused...

Страница 14: ...overly bright areas of the background brightness of the overall screen so that the darker areas are reproduced with more clarity This provides a balanced scene where all objects are properly exposed...

Страница 15: ...configure the day and night related setting for the camera The camera can turn the IR infrared filter on or off Mode COLOR AUTO B W EXT DAY NIGHT DAY NIGHT AUTO SENSE SEL SENSOR D N LEVEL 237 D N DEL...

Страница 16: ...IDTH Adjust width of MD area LEFT RIGHT Adjust the location of the MD area with boundary LEFT and RIGHT TOP BOTTOM Adjust the location of the MD area with boundary TOP and BOTTOM DEGREE Adjust sensiti...

Страница 17: ...DTH Adjust width of MASK area LEFT RIGHT Adjust the location of the MASK area with boundary LEFT and RIGHT TOP BOTTOM Adjust the location of the MASK area with boundary TOP and BOTTOM COLOR Select MAS...

Страница 18: ...ms down the center area and brightens up the side area Select 2DNR ON OFF 2DNR Select MIRROR ON OFF MIRROR FONT COLOR Select FONT COLOR level 0 15 Select IDR TITLE level 0 15 Adjust CONTRAST level 0 2...

Страница 19: ...R GAIN 176 END 5 COMM RS485 ADJUST The camera can be controlled remotely by a control keypad using a RS485 connection CAM ID Select the camera ID 001 255 BAUD RATE Select serial communication speed 24...

Страница 20: ...DISP VERSION END OFF OFF ON 01 00 ZOOM SEL SET PRESET SAVE END PRESET1 PRESET 01X SET PRESET1 FACTORY Restores the factory default settings LENS ADJ Adjust the zoom and focus of lens SAVE END Saves a...

Страница 21: ...8 IR LED SENSOR LED Lighting Distance Camera Control 60M External remote control ADKEY RS485 IR LED 78EA Sensor 1EA Electronic Shutter 1 60 1 100 000 sec 1 50 1 100 000 sec SENSOR AGC D N LEVEL DELAY...

Страница 22: ...policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been...

Страница 23: ......

Страница 24: ...quarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5...

Отзывы: