background image

 

 

Figure 1 

Exploded View 

XX077-50-00 Rev 1202 S2000-MSH-HHB Heater/Blower Version 

Introduction 

  5 

Содержание S2000-MSH-HHB Surveyor 2000

Страница 1: ...life critical situations and must not be used for this purpose Copyright 2002 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Technical Support 80...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...and Inspection 3 Accessory Kit 3 INSTALLATION 6 Mounting the Unit 6 OPERATION 8 MAINTENANCE 8 Care and Cleaning of Clear Acrylic Domes 8 Fuse Replacement 8 SHIPPING INSTRUCTIONS 9 CABLE RECOMMENDATIONS 10 Twisted Pair Cable 11 TECHNICAL INFORMATION 12 XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Contents 1 ...

Страница 6: ...Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 2 Quick Installation XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version ...

Страница 7: ... Enclosure a sealed Lower Dome assembly a Power Termination Block and mounting studs for the Surveyor2000 Camera Drive In addition the Housing provides outside holes for external mounting brackets and tamperproof hardware for Lower Dome removal Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory It is the carrier s responsibility to provide suitable deli...

Страница 8: ...solution camera Exview HAD CCD S2 MW22C 8216 01 1 4 in monochrome camera CCIR version 22x zoom high resolution camera Exview HAD CCD Table 2 Surveyor2000 Camera Drive Models Product Codes and Descriptions Model Product Code Description S2000 MSH WM 7620 00 Wall Mount with Tamperproof Bit S2000 MSH CM 7619 00 Ceiling Mount with Tamperproof Bit S2000 MSH S 7711 00 Sunshield can only be used with Wal...

Страница 9: ...Figure 1 Exploded View XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Introduction 5 ...

Страница 10: ... pre installed Tamperproof Screws Use the Tamperproof Bit provided with Mounting Bracket for installing screws 4 Prepare the Termination Boxes and cables There should be a maximum of 5 cables for power video communications alarm and relay Route the cables through the Liquid Tight Conduit Fitting and leave about 12 in 305 mm length for connection to the Camera Drive for every cable except power The...

Страница 11: ... open J3 8 RO Response out Table 4 Electrical Connections 7 Configure communication and address DIP switches For example DIP SWITCH S1 Address 1 1 ON 2 OFF 4 OFF 8 OFF 16 OFF 32 OFF 64 OFF 128 OFF DIP SWITCH S2 typical configuration 1 ON NTSC 2 OFF VPS 3 OFF DUPLEX 4 OFF RS 422 5 through 8 OFF not used For a detailed description of DIP switch configuration refer to the Configuration section of the...

Страница 12: ...r using a lint free soft paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior may be removed with a nonabrasive wax using a soft cleaning cloth Caution Excessive rubbing of the Lower Dome surface can cause permanent scratches 5 Clean all surfaces with any soft cleaning cloth and a mild glass cleanser suitable for acrylic plastic Fuse Replacement Two fuses...

Страница 13: ...d Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation a Complete description of the problem and circumstances under which it occurs b Unit s original date of purchase if still u...

Страница 14: ...ture quality and cable distance to provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refers to bare copper and TC refers to tinned copper Recommended Coaxial Cable Types Cable Type Belden Type No Alpha Type No West Penn Type No Type Center Conductor Type Shield and Coverage DC Resistance ohms 100...

Страница 15: ...ons Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the CPU Keypad and the Camera Dome Assembly The characteristics of the cables in Table 6 should be used as a guideline when cables other than...

Страница 16: ...alent 8 75 btu min 2 2 kg cal min Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage of the heat generated will be less and will vary from product to product These figures are provided as an aid in determining the extent of cooling required for an installation Program Memory Type Field reprogrammable flash type memory Connectors Types Communicatio...

Страница 17: ...y function activation calling autotours tour repeat or chaining tours Autotour Capabilities 2 autotours available with 360 pan tilt and zoom functions per autotour Programming is done in real time with joystick and push buttons Preset Solving Speed 1 second nominal Preset Repeatability 0 3 maximum Alarm Capabilities 4 alarm inputs Individual input enable disable Alarm report to CPU enable disable ...

Страница 18: ... Programmable for Camera Preset Sector and Alarms Fixed for Relay function and lens status Camera 1 for each Preset 79 maximum Sector 16 maximum Alarm 4 maximum Individual type enable disable 20 characters maximum Selectable position MECHANICAL S2000 MSH Housing only Application Indoor or outdoor Mounting Ceiling or Wall mounting with separately purchased Mounting Brackets See Table 3 Cable Access...

Страница 19: ...2000 MSH WM 11 75 lb 5 3 kg S2000 MSH CM 9 5 lb 4 3 kg Construction Housing 13 gauge 0 089 in 23 mm thick welded steel Mounts 0 19 in 4 8 mm thick steel Finish Paint Color Gray Figure 2 Dimensions XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Technical Information 15 ...

Страница 20: ... 122 F 40 to 50 C Note The Sunshield cannot be used with the S2000 MSH CM Ceiling Mount Bracket Operating Humidity Range 100 relative humidity Storage Temperature Range 40 to 150 F 40 to 65 C Storage Humidity Range Up to 90 relative noncondensing Ingress Protection EN60529 IP 65 rated Wind Load 90 mph using optional ceiling or wall mount 16 Technical Information XX077 50 00 Rev 1202 S2000 MSH HHB ...

Страница 21: ...NOTES XX077 50 00 Rev 1202 S2000 MSH HHB Heater Blower Version Technical Information 17 ...

Страница 22: ...rters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...