CONNECTOR/PIN
NUMBER
CONNECTOR TYPE
CONNECTOR/PIN LABEL
SIGNAL NAME
BNC (female)
VIDEO (J1)
J1
VIDEO
Video output
TERMINAL BLOCK
POWER (TB1)
TB1-1
H
Hot
TB1-2
N
Neutral
TB1-3
No connection
RJ-45
ALARM (J2)
J2-1
ALARM1
Alarm input 1
J2-2
VSSA
Ground
J2-3
ALARM2
Alarm input 2
J2-4
VSSA
Ground
J2-5
ALARM3
Alarm input 3
J2-6
VSSA
Ground
J2-7
ALARM4
Alarm input 4
J2-8
VSSA
Ground
TERMINAL BLOCK
COMM (TB3)
TB3-1
VSSA
Ground
TB3-2
RO+
Response out +
TB3-3
CI-
Command in -
TB3-4
RO-
Response out -
TB3-5
CI+
Command in +
RJ-45
COMM/RELAY (J3)
J3-1
CI+
Command in +
J3-2
RELAY NC
Relay, normally closed
J3-3
VSSA
Ground
J3-4
RO-
Response out -
J3-5
CI-
Command in -
J3-6
RELAY C
Relay, common
J3-7
RELAY NO
Relay, normally open
J3-8
RO+
Response out +
Table 4
Electrical Connections
7.
Configure communication and address DIP switches. For example:
DIP SWITCH S1 (Address 1):
1 - ON, 2 - OFF, 4 - OFF, 8 - OFF, 16 - OFF, 32 - OFF, 64 - OFF, 128 - OFF
DIP SWITCH S2 (typical configuration):
1 - ON (NTSC), 2 - OFF (VPS), 3 - OFF (DUPLEX), 4 - OFF (RS-422), 5 through 8 - OFF (not used)
For a detailed description of DIP switch configuration, refer to the Configuration section of the
Surveyor2000 Installation & Operation Manual XX031.
8.
Lift the Camera Drive up to the Housing. Align the 3 Drive Screws with the 3 Mounting Standoffs in the
proper position and tighten the 3 Captive Drive Mechanism Screws. Verify that none of the cables are
pinched, or interfering with, the Drive installation.
9.
Attach the Lower Dome using the previously removed nine (9) Tamperproof Screws.
10.
Installation is complete.
XX077-50-00 Rev 1202 S2000-MSH-HHB Heater/Blower Version
Installation
•