24
•
Reference
XX137-65-00 Rev 1107 Roughneck V910 Dome Cameras with PoE
Network Cable
Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor
performance when cables other than the recommended types, or equivalent, are used.
Materials
Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl
chloride (PVC). It has better electrical characteristics than Polyethylene and resists flames, sunlight and most solvents, but
is more vulnerable to moisture.
Cable Types
The most commonly used cable types are CAT5, CAT5e and CAT6. These category cables are best suited for Ethernet
network applications.
Choose a Belden cable type by referring to the characteristics listed below. The Table below should be used as a
guideline when cables other than Belden are used. Materials and construction must follow the guidelines above.
CABLE TYPE
WIRE SIZE
(AWG)
INSULATION
MATERIAL
JACKET
MATERIAL
CATEGORY
BANDWIDTH
(MHz)
MAXIMUM
DISTANCE
(ft/m)
NUMBER OF
TWISTED
PAIRS
Belden 1624P
24
Fluorinated
Ethylene
Propylene
Low Smoke
PVC
5
100
328/100*
4
Belden 1583A
24
Polyolefin
PVC
5e
100
328/100
4
Belden 1585A
24
Fluorinated
Ethylene
Propylene
PVC
5e
100
328/100
4
* For any cable in the system exceeding 300 ft (75 m), it is recommended to use Cat5e or higher to maintain good signal integrity.
Belden Inc.
http://www.belden.com/ (800)
235-3361
Table
Recommended Network Cable Types
Содержание ROUGHNECK V910-W3312DNV4-PoE
Страница 2: ......
Страница 10: ...4 Installation XX137 65 00 Rev 1107 Roughneck V910 Dome Cameras with PoE MAC Address...
Страница 11: ...XX137 65 00 Rev 1107 Roughneck V910 Dome Cameras with PoE Installation 5 Figure 1 Exploded View...
Страница 37: ...XX137 65 00 Rev 1107 Roughneck V910 Dome Cameras with PoE Vicon Standard Equipment Warranty 31 Notes...