10
•
Installation
XX137-65-00 Rev 1107 Roughneck V910 Dome Cameras with PoE
CONNECTOR/PIN
NUMBER
CONNECTOR TYPE
CONNECTOR/PIN LABEL
SIGNAL NAME
TERMINAL BLOCK
POWER (TB3)
TB3-1
H
Hot
TB3-2
N
Neutral
TERMINAL BLOCK
ALARM (P1)
P1-1
ALARM OUT
Alarm output
P1-2
GND
Ground
P1-3
ALARM IN
Alarm input
RJ-45
LAN (J7)
J7-1
TX +
Tr
J7-2
TX -
Transmit -
J7-3
RX +
R
J7-4
POE POWER
PoE Power
J7-5
POE POWER
PoE Power
J7-6
RX -
Receive -
J7-7
POE POWER
PoE Power
J7-8
POE POWER
PoE Power
1/8-IN. PHONO
AUDIO
J3
MIC
Audio In
J6
SPK
Audio Out - N/A
Wiring Connections
Dome Power Connections
Note: Vicon systems and components, like most electronic equipment, require a clean, stable power source.
Voltage irregularities such as surges, drops, and interruptions can affect the operation of your
equipment and, in severe cases, damage certain components.
Power (24 VAC) is connected through a two-position terminal connector on the PC board (TB3). Refer to
Table 2 for the input power connections. This is only for installations requiring heater power.
Note: Use only a UL Listed Class 2 indoor/dry or Class 3 outdoor/wet rated power supply.
1. Locate the power cable terminal on the PC board (removable terminal block).
2. Strip approximately 1 in. (25 mm) of insulation off power cables. Then strip off approximately 0.25 in.
(6 mm) of insulation off each individual wire. Refer to Figure 6. Connect the wire into the terminal block.
Repeat for each connection. Refer to Table 2.
3. Connect the terminal block onto the board connector.
The dome accepts 24 VAC for installations requiring the heater, for heater and camera power.
Figure 6
Cable Preparation