background image

Creating a Configuration

  |

3-71

 

Pilot Lite 

XX196-00 

 

 Tour Triggered Event 

Field Description 

Event # 

This column will display the selected event number.    

Tour # 

A predefined tour that was set up with the 
Sequential Tours screen. Refer to the 

Video Switch 

Setup

 section. 0 indicates no tour. 

Monitor # 

A monitor from 1 – 8 that has been defined in the 
system. 0 indicates no monitor. 

All selections are made using the Options Wizard. To change a field’s value, 
proceed as follows: 

1.  Select the field that you wish to modify using the Available Field 

selection box. You can scroll through all available options. 

2.  Upon selection, the title below Available Field will change to the 

parameter selected and the appropriate values will display in the 
selection box. 

3.  Select All for all, Selected Only for an item that is highlighted in the 

list or From to specify a range. 

4.  Click Update to implement the changes. 

Содержание Pilot Lite V1522

Страница 1: ...sely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2008 Vicon Industries Inc All rights reserved Product specifications subject to change without notice VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL FREE 800 645 9116 24 Hour Te...

Страница 2: ......

Страница 3: ...in tight spaces where they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent damage due to lightning and power line surges 13 Power Lines Do not locate outside cables over power or utility lines where they can fall and make direct contact Contact with power...

Страница 4: ...uipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should c...

Страница 5: ...2 Unpacking 2 2 Installing the Unit 2 3 Attaching the Tilt Stand 2 3 Attaching the Mounting Ears and Handles 2 4 Connections and Wiring 2 5 Camera Connection 2 6 Monitor Connection 2 7 Keypad Connection 2 8 Receiver Connection 2 9 Alarm Inputs 2 10 Alarm Relay Output 2 12 Relay Audio Switcher AUDIOSWITCH 2 13 Operation 2 14 Front Panel 2 14 Control Keys 2 14 Function Keys 2 15 LCD Display 2 16 ...

Страница 6: ...nging System Time and Date 2 21 Shutdown 2 22 Chapter 3 Configuration 3 1 Navigating the Configurator 3 2 Menu Bar 3 2 File 3 3 Saving a Database Configuration 3 4 Pilot Application 3 4 Edit 3 5 Admin 3 5 Video Switch Setup 3 6 Keypads 3 7 Cameras 3 7 Monitors 3 8 Alarms 3 8 Tools 3 9 Help 3 9 Toolbar 3 10 System Summary 3 11 Creating a Database 3 12 Creating a Configuration 3 13 Keypads 3 14 Keyp...

Страница 7: ...Switch Setup 3 45 Sequential Tour 3 45 Salvo Switch 3 50 Default Callup Values 3 51 Assign Dial Up Numbers Dial Up Salvo 3 52 Assign Dial Up Numbers Dial Up Tour 3 53 Assign Dial Up Numbers Dial Up Camera 3 54 Camera Monitor Partitions 3 54 Administration 3 55 Host Port 3 55 Timed Events 3 57 Triggered Events 3 69 Partitioning 3 75 Keypad Monitor Partitions 3 75 Camera Partitions 3 76 Camera Monit...

Страница 8: ...4 4 Cable Recommendations 4 5 Video Cabling 4 5 Materials 4 5 Cable Types 4 5 Video Control Cabling 4 6 Twisted Pair Cable 4 7 Materials 4 7 Cable Types 4 7 Cable Suppliers 4 8 Shipping Instructions 4 9 Technical Specifications 4 10 Electrical 4 10 Video 4 10 Mechanical 4 11 Environmental 4 11 ...

Страница 9: ...ite are registered trademarks or trademarks of Vicon Industries Inc Linux is a registered trademark of Linus Torvalds Gnome is a trademark of The GNOME Project Slo Blo is a registered trademark of Littelfuse Belden and Datalene are registered trademarks of Belden Inc ...

Страница 10: ...viii Table of Contents ...

Страница 11: ...ot Lite XX196 00 1 Chapter 1 Introduction This chapter provides general information about the Pilot Lite The chapter consists of the following topics Topic Page General Information 1 2 Organization of this Manual 1 4 Glossary 1 5 ...

Страница 12: ...tor The Configurator provides an intuitive graphical user interface that enables you to set up system parameters such as Timed or Triggered Event Programming Keypad Setup Receiver Profile Configuration Camera Setup Titling and Identification of Cameras Monitors and Presets Monitor Setup Salvo and Tour Configuration Alarm Processing Configuration The Pilot Lite has been configured with system defau...

Страница 13: ...lly or automatically Salvos may be called up manually or by alarm Each salvo can have a unique combination of camera monitor and preset position The Pilot Lite also provides touch sensitive front panel controls with an integral keypad and LCD display Many common operations can be performed using the front panel controls System Capabilities The Pilot Lite supports the following 32 Cameras 8 monitor...

Страница 14: ...es how to install the Pilot Lite and operation instructions including a description of navigating the Linux operating system 3 Configuration Describes how to create custom profile for your system 4 Maintenance Describes basic system maintenance reference information shipping instructions and technical specifications for the system ...

Страница 15: ...rogrammed pan tilt and or zoom actions that are executed by a single command Receiver A device used to communicate with PTZ cameras and Pan and Tilt devices PTZ dome cameras have built in receivers Salvo Simultaneous display of video from various camera stations on various monitors Stack A list of active alarms Tour Series of preprogrammed video displays from various camera stations on a monitor V...

Страница 16: ...1 6 Chapter 1 Introduction XX196 00 Pilot Lite ...

Страница 17: ...t Lite XX196 00 2 Chapter 2 Installation and Operation This chapter provides installation and operation information for the Pilot Lite The chapter consists of the following topics Topic Page Installation 2 2 Operation 2 14 ...

Страница 18: ...esk or shelf Rack mounting brackets are supplied with the Pilot Lite Accessory Kit Unpacking Carefully open the carton Remove the Accessory Kit and the unit from the box and place them on a large flat working surface Open the Accessory Kit and verify the hardware contained in the kit against the following table Vicon Part Number Description Qty Purpose 1298530501 Mounting Ears V1522ADVS 2 For rack...

Страница 19: ...Configurator software 1806524903 3 conductor Line Cord 115 VAC Used to connect the unit to 115 VAC power 11806524902 3 conductor Line Cord 220 VAC Used to connect the unit to 220 VAC power F001730201 Fuse 0 75A 5 X 20MM 250V Slo Blo 1 Replacement fuse V75TR SHD 75 Ohm Terminator Used to terminate the D Shell Looping connectors on the rear panel Installing the Unit The following paragraphs provide ...

Страница 20: ...of screw holes Attach it to the unit with the supplied hardware 4 Remove the adhesive backing from the bumper feet and attach them approximately 12 inches apart and approximately 1 inch from the rear panel Attaching the Mounting Ears and Handles The mounting ears are used to attach the unit to a rack The handles allow the unit to be easily slid in and out of the rack if drawer mounted Install the ...

Страница 21: ...n power switch for system Press and hold momentarily to boot Pilot Lite Looping Connectors D Shell connectors used to loop video from cameras to other devices Camera Inputs BNC composite connectors for cameras 1 32 Terminate any unused BNC connectors on the panel with a 75 ohm termination AudioSwitch Used to connect Vicon Relay Audio Follow Video switcher to Pilot Lite Alarm Inputs Terminal block ...

Страница 22: ...tion on the type of cables to be used for video connection Up to 32 cameras may be connected to the unit Connect each camera by routing a properly terminated coaxial cable between each camera and the unit Unused BNC connectors must be terminated with a 75 ohm terminator To loop camera outputs to other devices connect a 15 pin D shell cable to the looping connectors Each looping connector is labele...

Страница 23: ... 1 9 17 25 Monitor Connection Note Refer to the Cable Recommendations section in the Maintenance chapter for information on the type of cables to be used for video connection Up to 8 monitors may be connected to the unit Connect each monitor by routing a properly terminated coaxial cable between each monitor and the unit Unused BNC connectors must be terminated with a 75 ohm terminator ...

Страница 24: ...e lines Response signals are used to transmit information such as communication failures to the Pilot Lite Command signals which send control information from the Pilot Lite to the keypad are always required Connect the keypads or IDL to the KEYPAD terminal block as follows 1 Select the 6 Position Terminal Block Plug part number F004802508 from the Accessory Kit 2 Route the appropriate wires from ...

Страница 25: ...alarms and communication failures to the Pilot Lite Command signals which send control information from the Pilot Lite to the receiver are always required Simplex operation requires the use of command lines only The operating mode must be chosen or determined for existing installations before the following procedure can be performed Connect the receivers or IDL to the RECEIVERS terminal block as f...

Страница 26: ...Connect the alarms as follows 1 Select the 16 Pin Terminal Block Plug part number S56G0000004 from the Accessory Kit Note There are four terminal block plugs One for each 16 pin upper and lower bank on the terminal blocks 2 Route the appropriate wires from the alarms to the unit 3 Using wire strippers remove approximately 0 25 in 0 64 cm from the two wires 4 Note the position of pins 1 9 17 and 25...

Страница 27: ...13 ALARM 7 13 ALARM 15 14 GND 14 GND 15 ALARM 8 15 ALARM 16 16 GND 16 GND ALARM 17 31 Terminal Block Plug Pin Name Pin Name 1 ALARM 17 1 ALARM 25 2 GND 2 GND 3 ALARM 18 3 ALARM 26 4 GND 4 GND 5 ALARM 19 5 ALARM 27 6 GND 6 GND 7 ALARM 20 7 ALARM 28 8 GND 8 GND 9 ALARM 21 9 ALARM 29 10 GND 10 GND 11 ALARM 22 11 ALARM 30 12 GND 12 GND 13 ALARM 23 13 ALARM 31 14 GND 14 GND 15 ALARM 24 15 ALARM 32 ...

Страница 28: ...nal device which may be wired normally open or normally closed Connect the external device as follows 1 Select the 3 Position Terminal Block Plug part number F004802505 from the Accessory Kit 2 Route the appropriate wires from the external device to the unit 3 Using wire strippers remove approximately 0 25 in 0 64 cm from the two wires 4 Note the position of pin 1 on the terminal block 5 Connect t...

Страница 29: ...ot Lite s internal video switching system For example the audio signal from an intercom microphone associated with a camera can be switched to a speaker at the guard station at the same time the video is switched to the guard s monitor One ribbon cable is required to connect the Pilot Lite to a relay audio switcher This cable is included with the Relay Audio Follow Video Switcher It is connected t...

Страница 30: ...c system functions and utilities Front Panel The Pilot Lite has a touch sensitive front panel The panel is divided into logical groupings Control Keys Three sets of control keys are provided for camera lens control You can zoom in or out using the Zoom controls The Focus control enables you to adjust the camera lens for the best clarity The Iris control regulates the amount of light entering the c...

Страница 31: ... 23 ENTER To recall a Preset Press PRESET followed by the preset number on the numeric keypad and then PRESET again For example to recall Preset 23 press PRESET 23 PRESET Note The Preset Store function can be disabled using the General System Settings screen in the Configurator Preset Recall is always active Refer to the Configurator chapter Tools section for more information MENU Press MENU to ad...

Страница 32: ...Non Sequencing Alarms If the front panel is assigned to an alarm monitor pressing ALARM will acknowledge the alarm Sequencing Alarms If the front panel is assigned to a alarm monitor pressing ALARM will stop the alarm sequence At this point the alarm is steady on the monitor The next press acknowledges the alarm and restarts the sequence FAIL The FAIL LED lights to indicate that there is a communi...

Страница 33: ... a menu option or storing a preset The BACK key returns you to the previous action or state It works with monitor camera preset menu etc selections Two USB ports are provided on the front panel for external flash drive or USB hard drive connection These or the rear panel USB ports can be used for Configurator program updates You can also connect a USB mouse and keyboard to the front or rear panel ...

Страница 34: ...efine the CCTV equipment user preferences control and management of events alarm modes and other information required to control the CCTV system The Configuration chapter describes the Configurator how to use it to program the CCTV system in detail Note The Pilot Lite has been configured with system defaults that should satisfy most installations with no need for further customization For many use...

Страница 35: ...A brief description of these follows For more information on the operating system and the user interface refer to the applicable documentation and help system Accessing the Operating System Online Help The system uses the GNOME desktop interface To access the online help click System Help on the menu bar The GNOME Help Browser will display ...

Страница 36: ... Installation and Operation XX 196 00 Pilot Lite Operating System Root Password The operating system root password is 123456 You can change it by accessing the System menu and selecting Preferences Personal Password ...

Страница 37: ...me and Date To change the system time and or date right click time display in upper right hand corner and proceed as follows 1 The drop down menu will display Select Adjust Date Time 2 You will be prompted to enter the root password The default is 123456 ...

Страница 38: ...allation and Operation XX 196 00 Pilot Lite 3 The Date Time Properties dialog box displays 4 When you have completed your changes click OK Shutdown To shut down the system click the Power Off icon at the top of the screen ...

Страница 39: ...Operation 2 23 Pilot Lite XX196 00 The system shutdown dialog box displays Click Shut Down ...

Страница 40: ...2 24 Chapter 2 Installation and Operation XX 196 00 Pilot Lite ...

Страница 41: ... and how to use the Configurator to customize your system The chapter consists of the following topics Topic Page Navigating the Configurator 3 2 Menu Bar 3 2 Toolbar 3 10 System Summary 3 11 Creating a Database 3 12 Creating a Configuration 3 13 Keypads 3 14 Cameras 3 17 Monitors 3 21 Alarms 3 30 Video Switch Setup 3 45 Administration 3 55 Partitioning 3 75 Tools 3 79 ...

Страница 42: ...n Configurator screen has three components the Menu Bar the Toolbar and the System Summary They are described in the following paragraphs Menu Bar The menu bar provides access to all of the Configurator functions and options The menu bar functions and submenus are briefly described in the following paragraphs Program functions that are accessed from the menu bar are described in detail later on in...

Страница 43: ...e configuration New Opens the 1522 Pilot Lite Database Wizard Save As Allows you to save the configuration with a different file name See the Save As dialog screen shot that follows System Summary Displays the System Summary screen Toolbar Toggles the toolbar on and off Default is on Quit Closes the Configurator ...

Страница 44: ...3 4 Chapter 3 Configuration XX196 00 Pilot Lite Saving a Database Configuration Pilot Application Pilot Application Submenu Description Start Pilot Starts the Pilot V1522 application ...

Страница 45: ...from one place to another Paste Inserts a cut or copied selection Delete Removes a selection Select All Selects an entire group of text or page Admin Admin Submenu Description Host Port Accesses the Host Port screen which enables you to set priorities for the host port or keypad s Timed Events Accesses the Timed Events screen which allows you to program up to six timed event types ...

Страница 46: ...ou to define salvos Default Callup Values Accesses the Monitor Displays screen and allows you to set the default action of the monitors when the system is powered on Assign Dial Up Numbers Dial Up Salvo Accesses the Dial Up Salvo screen and allows you to redefine the salvo numbers Dial Up Tour Accesses the Dial Up Tour screen which allows you to define your own tour numbers Dial Up Camera Accesses...

Страница 47: ...e Keypad Monitor Partitions screen which enables you to partition monitors to keypads Cameras Cameras Submenu Description Cameras Accesses the Cameras screen which allows you to rename and renumber cameras and set other functions Preset Titles Accesses the Preset Titles screen which allows you to name presets that you have programmed for PTZ cameras Camera Partitions Accesses the Camera Partitions...

Страница 48: ...s Submenu Description Alarm Stack Mode Accesses the Alarm Stack Mode screen that allows you to select Common Stack Independent Stack or First Available alarm activity Alarm Action Accesses the Alarm Action screen which enables you to define settings for the alarms Receiver Action Accesses the Receiver Action screen which allows you to define settings for the PTZ cameras upon alarm Input Controls A...

Страница 49: ...Port Global Settings Accesses the General System Settings screen which enables you to make changes to system defaults Database Log Displays the Database Log file which provides a status on all system functions and parameters Help Help Submenu Description About Displays the About Vicon Pilot screen which lists the operating system Configurator version database version and provides the path to where...

Страница 50: ... screen For example if you go back 3 times and then go forward 3 times you will be at the top screen Home Accesses the System Summary screen Open Accesses the Open database dialog box Save As Opens the Save As dialog box Keypads Opens the Control Keypads screen Monitors Opens the Monitor Displays screen TDT Opens the OSD screen Cameras Opens the Cameras screen Alarms Opens the Alarm Input Controls...

Страница 51: ...Navigating the Configurator 3 11 Pilot Lite XX196 00 System Summary The System Summary displays the current system settings Clicking an item in the list will access the appropriate screen ...

Страница 52: ...re the database is stored When creating a profile please not the following If you use the current name that profile will be overwritten When you create a new profile it will automatically be loaded into the Configurator and be loaded whenever the system is started Always restart the Pilot Lite application when changing databases Note The Configurator is also used with the Pilot Plus V1544 Video Sw...

Страница 53: ... not be necessary to modify the configuration with the Configurator The following paragraphs guide you through the process of defining a configuration for your system Notes 1 The following paragraphs provide instructions for creating a configuration file using the Options Wizard If you are a more experienced user you can click on any of the fields or field items and make changes within the table Y...

Страница 54: ...ypad are contained in the field columns which are described in the following table A description of each field parameter is displayed on the screen when the field is selected Field Description Alarm Ack Selecting Enabled or Disabled will enable or disable the keypad s ability to acknowledge an alarm Default Monitor This setting defines the monitor that will automatically be selected at the specifi...

Страница 55: ... be set to Enabled to assign a priority 0 is the highest priority and 64 is the lowest Therefore a keypad assigned with a priority level of 0 will be able to seize control from any other keypad in the system This also applies to host port CPUs Auto Manual The Auto Manual setting is related to the Seize Control function and specifies whether the seize will occur automatically or must be initiated b...

Страница 56: ... Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original values Keypad Groups Refer to the Timed Events section in this chapter for a description of Keypad Gr...

Страница 57: ... in the Camera column The parameters that can be set for each camera are contained in the field columns which are described in the following table A description of each field parameter is displayed on the screen when the field is selected Field Description Receiver Model Sets the PTZ receiver s family model number or Fixed Camera for camera only Options are Fixed Camera V12xx V13xx Dome Vicoax Sim...

Страница 58: ... input number This allows camera numbering to be customized to suit the installation Use this field to type the dial up number for the currently selected input number Max is 999 Alarm Title Enter alarm titles in this field to identify the alarm number and or a description of the area viewed by the camera that is in an alarm condition To see the full title click on the grid and drag to resize Maxim...

Страница 59: ...iptive titles for PTZ receiver presets or you can use the default titles of Preset 1 through Preset 16 Each PTZ receiver can have up to 16 unique preset titles The preset title has a maximum of 10 characters To create a preset title proceed as follows 1 In the left column click on a Receiver and select a receiver 2 Click Receiver in the 3 column table The Options Wizard fields will become active 3...

Страница 60: ...re Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original values Camera Partitions Refer to the Partitioning section for a description of how cameras are partitioned ...

Страница 61: ...ch camera are contained in the field columns which are described in the following table A description of each field parameter is displayed on the screen when the field is selected Note This screen may also be accessed from the Video Switch Setup menu by selecting the Default CallUp Values submenu Field Description Alarm Monitor Selecting Enabled or Disabled will enable or disable the monitor s abi...

Страница 62: ...ually or automatically If a dwell time is entered an alarm will display until the acknowledge time passes then the alarm will be automatically acknowledged by the system Manual acknowledgment by a user is required if this function is set to Disabled Range 3 120 sec Alarm Order Alarm order settings are FIFO and Priority FIFO is first in first out signifying that the first alarm activated will be th...

Страница 63: ...iate values will display in the selection box 3 Select All for all monitors Selected Only for a monitor that is highlighted in the list or From to specify a range of monitors 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back t...

Страница 64: ...icking the Update button will save your changes Monitor Position The Monitor Position screen allows you to select the monitor and specify the following OSD Position for Monitor Use the Select a System Monitor selection box to select the monitor that you are setting up Checking the Use Large Characters will increase the display font size The Next button will advance you to the Title Position screen...

Страница 65: ...quence on the monitor and its placement on the screen Title Position Use this screen to change the TDT position on the monitor Press and hold the arrow buttons to move the titles up or down and right or left Press Next to advance to the Display Enable screen or back to return to the Monitor Position screen ...

Страница 66: ...y Enable screen allows you to choose which of the titles that you want to display on the monitor Check or uncheck any of the of the display options to enable or disable its display Press Next to advance to the Fade Control screen or Back to return to the Title Position screen ...

Страница 67: ...on box provides settings from 0 99 seconds Preset Fade Allows you to enable fade so that the preset title fades from the monitor after the period of time set in Fade Time or to disable fade so that the title remains onscreen The Fade Time selection box provides settings from 0 99 seconds Monitor Status Fade Allows you to enable fade so that the monitor status fades from the monitor after the perio...

Страница 68: ...be displayed using this screen Field Description Date Format Use the selection box to choose American MM DD YY Asian YY DD MM or European DD MM YY formats Time Format Use the selection box to choose 12 Hour or 24 Hour formats Press Next to advance to the Update screen or Back to return to the Fade Control screen ...

Страница 69: ...us screens You can apply changes to the selected monitor all monitors or a range of monitors Click the Update button to implement the changes Note Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original values ...

Страница 70: ...ed for each alarm monitor First Available Alarm Mode One stack is used for all alarm monitors but monitor priority levels determine the order in which alarm monitors will be used Cameras must be partitioned to monitors If a camera is partitioned from an alarm monitor the camera will display on the first alarm monitor according to viewing priority The Alarm Stacking Mode screen allows you to choose...

Страница 71: ... Out The first alarm activated will be the first alarm displayed on the alarm monitor the second alarm activated will be the next alarm displayed and so forth Sort by Priority Alarms will be listed in the order of the priority level defined in the Alarm Action screen Click Update to complete your selection Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the ch...

Страница 72: ...wn in part A except for the video from camera 10 at preset 01 The video from camera 10 at preset 01 is defined to be the video displaying on monitor 3 before any alarms are activated Part C illustrates the video displayed on monitors 1 2 and 3 when alarm 01 is activated As shown in Part A an active alarm 01 was programmed to display video as follows Camera 01 Preset 01 on monitor 1 Camera 20 Prese...

Страница 73: ... 1 or monitor 2 alarm video from alarm input 02 will display as shown in Part D Because all three monitors were included in the Edit Alarm Call Up for alarm input 02 alarm video displays on all alarm monitors Alarm 02 may be acknowledged from any alarm monitor 01 02 or 03 Common Stack Mode Example ...

Страница 74: ...02 has a higher priority than alarm 01 Part A of illustrates the Edit Alarm Call Up screens for two alarms Part B illustrates the video from specific cameras at specific preset positions All of the alarms shown in Part B are associated with either alarm 01 or alarm 02 except for the video from camera station 10 at preset 01 When alarms 01 and 02 are activated alarm 01 displays on monitor 01 becaus...

Страница 75: ...Creating a Configuration 3 35 Pilot Lite XX196 00 Independent Stack Mode Example ...

Страница 76: ...ms will be placed on the stack as defined by the Alarm Input Order field on the Alarm Stacking Mode screen In part B alarm 1 occurs and routes video from camera 1 preset position 1 to the monitor with the highest priority level Note that monitors with lower priority numbers are defined by the system as the high priority level monitors For example priority level 1 is higher than priority level 2 Bo...

Страница 77: ... 37 Pilot Lite XX196 00 If additional alarms occur they will be placed in an alarm stack in either FIFO or Priority order as defined in the Alarm Input Order field of the Alarm Stacking Mode screen First Available Alarm Example ...

Страница 78: ... an alarm input number in that column will cause the alarm input number to be displayed in the 5 column table Alarm Input You can then set the parameters for alarm input by selecting the field columns which are described in the following table A description of each field parameter is displayed on the screen when the field is selected Field Description Priority Used to assign a priority level to an...

Страница 79: ...nitor Aux_1 Use this field to program an auxiliary relay contained in a receiver to respond to an alarm input and provide a control output Choices are N C On and Off Preset Used to select a preset position that may be recalled for each camera Enter 1 to 89 to recall the preset number stored in the receiver 0 No Preset All selections are made using the Options Wizard To change a field s value proce...

Страница 80: ... set the actions for each receiver by selecting the field columns which are described in the following table A description of each field parameter is displayed on the screen when the field is selected Field Description Alarm Enabled Used to enable or disable alarm action by a receiver Must be enabled to be processed indicates a fixed camera and the option is not available Home on Ack Set this fiel...

Страница 81: ...ing the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box c...

Страница 82: ... of patterns allows X IA alarms to operate as a group For example an Alarm Enable event using pattern A could be scheduled for daylight hours and pattern B could be reserved for night Refer to the Admin section Timed Events for more information Note X IA alarms should be used for critical surveillance areas rather than receiver alarms You can set the actions for each alarm input by selecting it in...

Страница 83: ...mple some alarms are activated when the contacts close and others when the contacts open If a normally closed momentary alarm is connected to a door the alarm is active only while the door is open Latching alarms remain in their current state for example a latching normally closed door alarm will activate when the door is opened and remain active until the alarm is acknowledged The default state o...

Страница 84: ... From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original values ...

Страница 85: ... monitor and then selects monitor tour 1 then that monitor displays camera 1 s preset 10 and then displays camera 2 s preset 1 A Salvo Tour is a simultaneous display of video from various cameras on various monitors unlike a Monitor Tour which displays video on only one monitor For example salvo 1 might be defined as the display of video from camera 8 on monitor 1 the display of video from camera ...

Страница 86: ...ble another tour may be activated Chain all touring may cease Halt or the tour may repeat Repeat The Chain command gives you the option to select any of the tour numbers for example Chain 23 to select tour number 22 Note When chaining tours add 1 to the tour number that you want to chain Therefore if you want to chain to tour 1 you would Chain 2 If you enter 0 the tour will repeat Entering 1 halts...

Страница 87: ...ster speed The speed setting is only applicable for the V15UVS V7UVS Surveyor Mini Dome SVFT and V1305R DC receivers Range 1 10 All selections are made using the Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field w...

Страница 88: ...le another tour may be activated Chain all touring may cease Halt or the tour may repeat Repeat The Chain command gives you the option to select any of the tour numbers for example Chain 23 to select tour number 22 Note When chaining tours add 1 to the tour number that you want to chain Therefore if you want to chain to tour 1 you would Chain 2 If you enter 0 the tour will repeat Entering 1 halts ...

Страница 89: ...he Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highli...

Страница 90: ...e field columns and their actions are described in the following table A description of each field parameter is displayed on the screen when the field is selected Field Description Step Use this field to select the step number from 1 8 The steps are displayed in sequence with step 1 being performed before step 2 etc Monitor Use this field to select the monitor number from 1 8 that will be used in ...

Страница 91: ...llows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Upda...

Страница 92: ...rom 1 to 999 that is not currently assigned For example if a user changes camera 1 s dial up to 99 then you can change salvo 1 s dial up from the default 301 to 1 All selections are made using the Options Wizard To change the Dial Up field s value proceed as follows 1 Select Dial Up in the Available Field selection box 2 In the Dial Up field scroll through and select the value that you want to ass...

Страница 93: ...on and may not be used during programming All selections are made using the Options Wizard To change the Dial Up field s value proceed as follows 1 Select Dial Up in the Available Field selection box 2 In the Dial Up field scroll through and select the value that you want to assign to the salvo 3 Make sure that Selected Only is chosen 4 Click Update to implement the changes Note The Settings box c...

Страница 94: ...l Up Camera Dial Up Camera numbers are accessed using the Cameras screen Refer to the Cameras section in this chapter for a full description of the screen Camera Monitor Partitions Refer to the Partitioning section in this chapter for a description of Camera Monitor partitions ...

Страница 95: ...ou to assign a priority to a host computer connected to the system so that it can seize control of a camera monitor from one of the keypads in the system Refer to the Keypads section for more information on keypad priorities There are 64 priority levels available with Level 0 having the highest priority Therefore if you assign the host computer priority 0 it will be able to seize control from any ...

Страница 96: ...ing the Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is h...

Страница 97: ...ds or keypad groups will have control over cameras at specified times Keypad groups are described at the end of this section The Timed Events screen has a two column table on the left and a multi column table on the right The multi columned table fields will change according to the type of event selected in the two column table You can set up 32 different timed events on the system The following p...

Страница 98: ...ystem 0 indicates no monitor Schedule Date The date the event will take place or begin if event will occur more than once Date format is MM DD YYYY Schedule Hour The hour of the day the event will take place Hour format is 24 hour mode 0 23 Schedule Minute The minute the event will take place Minute format is 0 59 Frequency The amount of times the event will occur Values are Not Set Once Weekly Da...

Страница 99: ...Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes ...

Страница 100: ...stem 0 indicates no monitor Schedule Date The date the event will take place or begin if event will occur more than once Date format is MM DD YYYY Schedule Hour The hour of the day the event will take place Hour format is 24 hour mode 0 23 Schedule Minute The minute the event will take place Minute format is 0 59 Frequency The amount of times the event will occur Values are Not Set Once Weekly Dai...

Страница 101: ...Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes ...

Страница 102: ... 32 that controls a PTZ camera Schedule Date The date the event will take place or begin if event will occur more than once Date format is MM DD YYYY Schedule Hour The hour of the day the event will take place Hour format is 24 hour mode 0 23 Schedule Minute The minute the event will take place Minute format is 0 59 Frequency The amount of times the event will occur Values are Not Set Once Weekly ...

Страница 103: ...Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes ...

Страница 104: ... begin if event will occur more than once Date format is MM DD YYYY Schedule Hour The hour of the day the event will take place Hour format is 24 hour mode 0 23 Schedule Minute The minute the event will take place Minute format is 0 59 Frequency The amount of times the event will occur Values are Not Set Once Weekly Daily Monthly Day of Week This field will automatically be populated automatically...

Страница 105: ... the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the origi...

Страница 106: ...rol over the cameras in the Camera Partition Keypad groups are defined using the Keypads Group screen Refer to the Keypads section 0 indicates no keypad group Camera Partition Selects the camera partition group that will be viewed or controlled by the keypads in the Keypad Group Camera Partition Groups are defined using the Camera Partitions screen Refer to the Cameras section 0 indicates no camer...

Страница 107: ...s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Select All for all Selected Only for an item that is highlighted in the list or From to specify...

Страница 108: ...isplaying a camera that the keypad should not see it will still see it If a tour is running on a monitor and the keypad dials into that monitor the tour will skip the cameras that are not allowed to be viewed by the monitor If a keypad with permission to view a camera calls up the camera to a monitor the keypad without permission will still be able to view the camera An alarm can still call up a c...

Страница 109: ...ore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original values Triggered Events Triggered event types are programmable events that respond to an alarm input Unlike a timed event which activates at a specified time of day triggered events activate when a...

Страница 110: ... alarms before you can define triggered events The Triggered Events screen has a two column table on the left and a multi column table on the right The multi columned table fields will change according to the type of event selected in the two column table You can set up 32 different triggered events on the system The following paragraphs describe the event types The field columns and their actions...

Страница 111: ...m 0 indicates no monitor All selections are made using the Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate values will display in the selection box 3 Sel...

Страница 112: ...ber Salvo A predefined salvo that was set up with the Salvo Switch screen Refer to the Video Switch Setup section 0 indicates no salvo All selections are made using the Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available ...

Страница 113: ...l values Preset Triggered Event Field Description Event This column will display the selected event number Preset Used to select a preset position that may be recalled for each camera Enter 1 to 89 to recall the preset number stored in the receiver 0 indicates no preset Receiver A receiver from 1 32 that controls a PTZ camera All selections are made using the Options Wizard To change a field s val...

Страница 114: ...t All for all Selected Only for an item that is highlighted in the list or From to specify a range 4 Click Update to implement the changes Note The Settings box contains two buttons Apply and Restore Clicking Apply will make the changes permanent Clicking Restore will cancel the changes that you have made and revert back to the original values Once you click Apply you cannot restore the original v...

Страница 115: ...ed The following paragraphs describe Keypad Monitor Partitions Assign a monitor to a keypad Camera Partitions Assign partition number to cameras for control purposes Camera Monitor Partitions Assign a camera or cameras to a mnitor Keypad Monitor Partitions You can assign control of various monitors to selected keypads To assign monitors to keypads proceed as follows 1 In the Keypad column select a...

Страница 116: ...of PTZ functions during specified times Camera Partitions enable you to define which cameras will be included in the groups by creating a partition number Up to 16 partitions are available In the example shown cameras 1 3 are part of Camera Partition 1 As part of this partition group viewing is permitted but pan tilt zoom functions are not allowed When this camera partition is chosen with a keypad...

Страница 117: ...t selection in the table or From to specify a range of cameras Note If View Camera and Control PTZ are both set to Yes for the cameras not selected the actions assigned to the partition will have no effect on the operator s ability to view them or control PTZ during the timed event The cameras will be both viewable and controllable 6 Click Update to implement the changes Note The Settings box cont...

Страница 118: ... move those cameras to the Selected Monitor can Not see these cameras list If you wish to move all or some of the non partitioned cameras back to the Selected Monitor can see these cameras list click the Add or Add All buttons When you have made your choices for the monitors click the Apply button If a camera is removed from a monitor all settings associated with that camera i e default callup sal...

Страница 119: ...eceiver Dome Port and Keypad Port The following table provides the selections and ranges available Field Description Select Pilot Serial Port Select the port whose settings you wish set The choices are Host Port Receiver Dome Port or Keypad Port Baud Rate Selects the data transmission rate for the equipment A range of 300 to 115200 is available Select the transmission rate applicable to your equip...

Страница 120: ...w method based on your equipment s requirements None is also an option All selections are made using the Options Wizard To change a field s value proceed as follows 1 Select the field that you wish to modify using the Available Field selection box You can scroll through all available options 2 Upon selection the title below Available Field will change to the parameter selected and the appropriate ...

Страница 121: ...d Keypad Click Set to Enabled to hear audible clicks when keypad is touched Default setting is Enabled Alarm Alert Set to Enabled to sound audible alarms Default is Enabled Note If Alarm Alert is enabled an audible alarm will sound each time alarm s are activated until the first alarm is acknowledged For example if alarms 1 2 and 3 activate then the alarm will sound until the first alarm is acknow...

Страница 122: ...ical synchronization Default is Disabled Note For VSYNC to work a reference camera must be connected to input 32 of the camera inputs The other cameras in the system must have their V Syncs aligned to the reference camera Click Update to save your changes Note The Settings box contains Apply and Restore buttons Clicking Apply will make the changes permanent Clicking Restore will cancel the changes...

Страница 123: ...Creating a Configuration 3 83 Pilot Lite XX196 00 Database Log Select the Database Log submenu to view a log of the database in text file format ...

Страница 124: ...3 84 Chapter 3 Configuration XX196 00 Pilot Lite ...

Страница 125: ...ance This chapter provides maintenance information for the Pilot Lite The chapter consists of the following topics Topic Page Introduction 4 2 Fuse Replacement 4 3 Storage 4 4 Cable Recommendations 4 5 Shipping Instructions 4 9 Technical Specifications 4 10 ...

Страница 126: ...er serviceable parts in the Pilot Lite Maintenance is limited to fuse replacement storage and cable recommendations for the unit Shipping instructions are provided should you need to ship the unit back to the factory Technical specifications are also provided in this chapter ...

Страница 127: ...urned off when replacing the fuse The fuse is located on the rear panel and is part of the power cord receptacle The fuse is contained in a plastic case To remove the fuse use a small screwdriver or other flat object such as a large paperclip to depress the retaining clip on the bottom of the fuse case and slide the case out Replace the fuse with a 0 75A 5 X 20MM 250V Slo Blo fuse ...

Страница 128: ...he unit for periods of 1 month or longer place the unit and a fresh desiccant drying agent in a container that provides a vapor barrier and vapor seal Then place the sealed storage container in a location where the temperature is maintained between 32 to 113 F 0 to 45 C ...

Страница 129: ...stranded center conductor Never exceed the manufacturer s minimum bend radius specification Use cellular foam polyethylene dielectric except where heavy moisture exists For moisture conditions use solid polyethylene dielectric cable with a heavy exterior insulation The shield must be copper braid providing 95 or better coverage Cable Types The cable types listed in the following table are the most...

Страница 130: ...5 15 0 49 Requires special BNC M connector due to 0 305 nominal O D Picture Quality vs Cable Length Maximum Cable Run ft m Picture Quality RG59 U RG 6 U RG 11 U Usable picture 1100 350 1500 450 2400 750 Clean picture 820 250 1000 300 1600 500 Best picture 400 120 530 160 820 250 For longer cable runs use a Vicon Video Amplifier to obtain a suitable picture Video Control Cabling Vicoax communicatio...

Страница 131: ...idually shielded twisted pair in a single jacket This configuration is the most convenient for RS 422 RS485 applications Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the unit and the receive...

Страница 132: ... 4 Maintenance XX196 00 Pilot Lite Cable Suppliers Belden Inc http www belden com 800 235 3361 Alpha Wire Company http www alphawire com 800 52 ALPHA 522 5742 West Penn Wire http www westpenn cdt com 800 245 4964 ...

Страница 133: ...ope contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances u...

Страница 134: ...ed at 1 A 30 V Fuse 0 75 A 5 X 20MM 250V SLO BLO Video Video Input Level 1 0 V p p nominal Input Output Impedance Terminated 75 ohms Looping High impedance 6 8 kohm Input to Input Isolation Typical 52 dB at 4 2 MHz Video Gain Unity 0 3 dB Video Frequency Flatness 100 kHz to 10 MHz 0 9 dB Total Bandwidth 1 Hz to 20 MHz 3 dB Tilt Less than 1 Field Line Short Time Distortion Less than 1 Chrominance t...

Страница 135: ...one input Not Used line input Not Used speaker output Not Used Mechanical Application Indoor Mounting All units may be rack mounted in a standard EIA compliant rack or desk or shelf mounted Dimensions Width W 17 63 in 448 mm Depth D 15 in 381 mm Height H 3 5 in 89 mm Weight 16 3 lb 7 4 kg Color Front Panel Silver Case Black Environmental Operating Temperature Range 32 to 122 F 0 to 50 C Operating ...

Страница 136: ...4 12 Chapter 4 Maintenance XX196 00 Pilot Lite ...

Страница 137: ...f the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no cost may be discontinued at any time without notice at Vicon s so...

Страница 138: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: