background image

XX018 Rev 200 NOVA V1400X-HSB-M

Shipping Instructions  

  19

Shipping Instructions

Use the following procedure when returning a unit to the factory:

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name

of the Vicon employee who issued the R.A.

Vicon Industries Inc.
89 Arkay Drive
Hauppauge, NY  11788
Phone: 631-952-CCTV; Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV

For service or returns from countries in Europe, contact:

Vicon Industries (U.K.) Ltd
Brunel Way
Fareham, PO15 5TX
United Kingdom
Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322

2. 

Attach a sheet of paper to the unit with the following information:

a. 

Name and address of the company returning the unit

b. 

Name of the Vicon employee who issued the R.A.

c. 

R. A. number

d. 

Brief description of the installation

e. 

Complete description of the problem and circumstances under which it occurs

f. 

Unit’s original date of purchase, if still under warranty

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection.

4.  Mark the R.A. number on the outside of the carton on the shipping label.

Содержание NOVA V1400X-HSB-M

Страница 1: ...XX018 V1400X HSB M Hot Standby Switchover Instruction Manual VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NY 11788...

Страница 2: ...nt will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has not been designed to be used in life critical si...

Страница 3: ......

Страница 4: ...ipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver...

Страница 5: ...s 2 Titler Connections 6 Alarm Connections 8 Video Switcher Connections 10 Supervisor Connections 11 Control Connections between Switchover Modules 15 Operation 16 Start Up Screen 16 Hot Standby Syste...

Страница 6: ...where it may be exposed to water or moisture This does not apply to outdoor camera housings outdoor pan and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Acces...

Страница 7: ...sult in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to...

Страница 8: ...ny programming change or operator action such as calling up a camera to a monitor is immediately communicated to the Secondary system In the event of a malfunction in the Primary system control is rou...

Страница 9: ...ivers in your system you must use the V1400X SSO E supervisor module as well as the V1400X SSO module Both V1400X SSO and V1400X SSO E modules connect to the V1400X CI M boards The V1400X SSO module m...

Страница 10: ...2 to pin 2 and so forth Note If you assemble the cables for these connections note that the cables must be shielded using the connector shells Figure 2 illustrates connections between the two CI cards...

Страница 11: ...3 J5 J6 J7 J8 J3 J4 V1400X CI M J5 J6 J7 J8 1 2 3 4 5 6 J2 J3 J4 J5 SYSTEM SUPERVISOR CPU V1400X SSO STANDBY PRIMARY J2 J17 J1 J16 J6 J9 J12 J15 J8 J11 J14 J7 J10 J13 SECONDARY CPU PRIMARY CPU Figure...

Страница 12: ...J5 J6 J7 J8 1 2 3 4 5 6 J2 J3 J4 J5 SECONDARY SYSTEM SUPERVISOR CPU V1400X SSO E STANDBY RECEIVERS DOMES 1025 1536 RECEIVERS DOMES 1537 2048 PRIMARY J6 J9 J12 J8 J11 J14 J7 J10 J13 SECONDARY CPU PRIMA...

Страница 13: ...ectors to allow the installer to make his own cables If the cables must be assembled by the installer connect pin 1 on the Primary system s end of the cable to pin 1 on Secondary system s end of the c...

Страница 14: ...X TC M J2 J3 J4 J5 TIME DATE TITLER CPU V1400X TSO OUTPUT OUTPUT STANDBY STANDBY TO T D T CAGES FOR OUTPUTS 01 64 STANDBY PRIMARY 1 2 3 4 5 6 CARD SLOT 6 TO T D T CAGES FOR OUTPUTS 65 128 J7 J1 J8 J2...

Страница 15: ...cular system configuration If they are not in the accessory pack the pack will contain the necessary mating connectors to allow the installer to make his own cables If the cables must be assembled by...

Страница 16: ...OUTPUT PRIMARY STANDBY STANDBY PRIMARY J2 J3 J4 J5 J6 J11 J7 J8 J9 J10 J11 J12 J12 SECONDARY CPU J10 J9 V1400X AC M J11 J12 1 2 3 4 5 6 CARD SLOT 5 ALARMS 001 256 RS 232 ALARM INTERFACE PORT ALARMS 25...

Страница 17: ...ble 5 Prepared cables may or may not be supplied in the accessory pack depending on the particular configuration If they are not in the accessory pack the pack will contain the necessary mating connec...

Страница 18: ...UTPUTS 65 128 J7 J1 J8 J2 J9 J3 J10 J4 J11 J5 J12 J6 Figure 7 Connections between V1400X VSO and V1400X VC M Cards Note If you use video loss detectors in your system be sure to connect the video loss...

Страница 19: ...ng connectors to allow the installer to make his own cables If the cables must be assembled by the installer connect pin 1 on the Primary system s end of the cable to pin 1 on Secondary system s end o...

Страница 20: ...J2 V1400X SV M PRIMARY CPU J4 J5 J7 STANDBY RS 232 HOST COMPUTER PORT RECEIVERS DOMES 0513 1024 STATUS DISPLAY MONITOR RECEIVERS DOMES 0001 0512 KEYPADS PRIMARY J2 J17 J1 J16 J6 J9 J12 J8 J11 J14 J7 J...

Страница 21: ...boards refer to the section beginning on page 2 Table 7 Connections for Keypads and Receivers Pin Number Function Pin Number Function 1 response IN 1 9 ground 2 response IN 1 10 command OUT 2 3 ground...

Страница 22: ...hand side of the rear panel These connectors allow control commands to be transmitted to the video title and alarm modules The screw terminal strip on the V1400X SSO module and V1400X SSO E module if...

Страница 23: ...was connected and communicating with a Secondary system during the last time it was powered If the Primary is powered without a Secondary system and then the Primary is powered down then this screen w...

Страница 24: ...rm if a CPU fails ACK Push this button to acknowledge an alarm Primary Illuminates if the Primary system fails Secondary Illuminates if the Secondary standby system fails STATUS 3 Primary Illuminates...

Страница 25: ...nt of the fuse as described below does not correct the problem contact Vicon s Service Department Power Down Procedure Should the Primary system need to be removed for maintenance simply remove power...

Страница 26: ...contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and...

Страница 27: ...nance 18 O Operation 16 P Phone Numbers 19 Programming 18 R Receivers 14 Returns 19 S Shipping Instructions 19 Support 19 T Telephone Numbers 19 Titler 6 V V1400 ASO 8 V1400X AC M 8 V1400X CI M 2 V140...

Страница 28: ...07 Vicon Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780...

Отзывы: