Vicon NOVA V1400 Скачать руководство пользователя страница 11

 

2  

  V1400X-CI-M Control Interface 

XX007 Rev 702 NOVA V1400 

V1400X-CI-M Control Interface 

 
The V1400X-CI-M Control Interface CPU is located in card slot 3 of the NOVA card cage. This CPU module 
is connected to receivers 1025-2048 (if needed in your system). You must also use terminators from the 
accessory kit on two of the connectors. Remaining connectors are not used. Refer to Figure 2, which shows 
V1400X-DL-1 Distribution Line Control (DL) units being used to connect multiple receivers to the system. 
Refer to Table 3 for pin connections. 
 
You must fabricate the cables using parts supplied in your accessory kit. Vicon recommends the cables 
shown in Table 2. Note that the cables must be shielded using the connector shells. 
 

Table 2 

Recommended RS-422 Cable Types 

 

Cable Type 

Maximum Distance  ft (m) 

Belden 9406 

5000 (1500) 

Belden 9402 

5000 (1500) 

Belden 8723 

8000 (2400) 

Belden 8162 

15,000 (4600) 

Belden 9729 

15,000 (4600) 

Belden 9182 

25,000 (7600) 

 

CARD SLOT 3

J3

J4

V1400X-CI-M

J5

J6

J7

J8

1
2
3
4
5
6

J2

J3

J4

J5

Use terminator 
from accessory kit.

Channel 2
receivers 1792-2048.

Channel 1
receivers 
1025-1280.

Up to 9 
units per 
DL.

V1400X-DL-1

V1400X-DL-1

Not used.

Not used.

Dome

Rcvr.

Channel 1
receivers 
1537-1791.

Up to 9 
units per 
DL.

V1400X-DL-1

V1400X-DL-1

Dome

Rcvr.

Use terminator 
from accessory kit.

Channel 2
receivers 1281-1536.

 

Figure 2 

Connections to the V1400X-CI-M Control Interface 

 

Note: You may also use Vicon’s 
V1400X-IDL Intelligent 
Distribution Line Control. 

Содержание NOVA V1400

Страница 1: ... warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2002 Vicon Industries Inc All rights reserved Product specifications subject to change wit...

Страница 2: ......

Страница 3: ...This page intentionally left blank ...

Страница 4: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocated the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should cons...

Страница 5: ......

Страница 6: ...702 NOVA V1400 Contents i Contents Introduction 1 V1400X CI M Control Interface 2 V1400X SV M Supervisor 3 V1400X AC M Alarm Control 5 V1400X TC M Titler CPU 6 V1400X VC M Video Switcher 6 Shipping Instructions 7 ...

Страница 7: ...re it may be exposed to water or moisture This does not apply to outdoor camera housings outdoor pan and tilt drives and other equipment designed for direct exposure to outdoor environments 8 Accessories Do not place this video product on any unstable surface or table The video product may fall causing serious injury to a person and serious damage to the video product Use only with a mounting acce...

Страница 8: ...t in a fire or electric shock Never spill liquid of any kind on the video product 18 Servicing Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 19 Damage Requiring Service Disconnect this video product from its power source and refer servicing to qualified serv...

Страница 9: ...iv Important Safeguards XX007 Rev 702 NOVA V1400 This page intentionally left blank ...

Страница 10: ...I M Control Interface provides receiver connections Card slot 4 V1400X VC M Video Switcher provides connections to video switching equipment Card slot 5 V1400X AC M Alarm Control provides local alarm connections Card slot 6 V1400X TC M Time Date Titler provides outputs to TDT card cages J2 J3 J4 J5 J2 J4 J5 J7 J3 J4 J5 J6 J7 J8 J10 J9 J11 J12 J2 J3 J4 J5 1 2 3 4 5 6 Figure 1 NOVA V1400 Rear Panel ...

Страница 11: ... the cables shown in Table 2 Note that the cables must be shielded using the connector shells Table 2 Recommended RS 422 Cable Types Cable Type Maximum Distance ft m Belden 9406 5000 1500 Belden 9402 5000 1500 Belden 8723 8000 2400 Belden 8162 15 000 4600 Belden 9729 15 000 4600 Belden 9182 25 000 7600 CARD SLOT 3 J3 J4 V1400X CI M J5 J6 J7 J8 1 2 3 4 5 6 J2 J3 J4 J5 Use terminator from accessory ...

Страница 12: ... programming menus To use all of the RS 232 commands available to the NOVA V1400 use connector J7 on the V1400X SV M Supervisor to connect a host computer to the system For RS 422 communications receivers and keypads refer to Table 2 for Vicon recommended cable types Note that the cables must be shielded using the connector shells You must fabricate the cables for these connections using parts sup...

Страница 13: ...X SV M connector J7 are not used CARD SLOT 2 Monitor 1 2 3 4 5 6 J2 J3 J4 J5 Channel 2 receivers 257 512 Channel 2 receivers 769 1024 Channel 1 keypads 1 32 Channel 2 keypads 33 64 V1400X DL 1 V1400X DL 1 Channel 1 receivers 1 256 Up to 9 units per DL V1400X DL 1 V1400X DL 1 Dome Rcvr J2 V1400X SV M J4 J5 J7 Keyboard Keyboard Channel 1 receivers 513 768 Up to 9 units per DL V1400X DL 1 V1400X DL 1...

Страница 14: ...J12 on the Alarm Control panel can be used for alarm serial printers and host computers so that if you have three host computers you do not have a serial printer Or if you have two alarm printers you can only have one host computer but that computer will be connected to J7 and will be able to use all command codes Note that RS 232 alarms 512 2048 are accessible through any of the three RS 232 port...

Страница 15: ...44 card cages for systems with less than 256 cameras To automatically synchronize to an external sync signal composite video or vertical sync pulses connect a coaxial cable to the BNC connector of the V1400X VC M and to the external source Note If you use video loss detectors be sure to connect the video loss detector VLD before any V1300X IA alarm interface device in the chain The video switcher ...

Страница 16: ...pe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstance...

Страница 17: ... Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: