background image

ii  

  List of Figures 

XX087-02 Rev 503 V1500 

List of Figures 

 

Figure 1 - Sample Networked V1500 System .................................................................................................................4

 

Figure 2 - Example of V1500 System on a Wide Area Network...................................................................................6

 

Figure 3 - V1500CPU Front and Rear Panels................................................................................................................8

 

Figure 4 - Netswitch-8 Position in the V1500 System ....................................................................................................8

 

Figure 5 - Location of Main and Front Panel Power Switches and LEDs...................................................................9

 

Figure 6 - Front and Rear Panels for Typical Configurations ...................................................................................10

 

Figure 7 - Example of a Typical Configuration

...................................................................................................................11

 

Figure 8 - Front and Rear Panels for V1500CDU-HSB-TYP.....................................................................................12

 

Figure 9 - Example of a Hot Standby Configuration ..................................................................................................13

 

Figure 10 - Example of a Customized V1500CDU-CC Card Cage............................................................................14

 

Figure 11 - Location of Card Label in the V1500CDU-CC Card Cage.....................................................................15

 

Figure 12 - LED Indicators for Typical Configurations .............................................................................................19

 

Figure 13 - LED Indicators for Hot Standby Configurations ....................................................................................20

 

Figure 14 - Inserting the Hot Standby Power Module ................................................................................................21

 

Figure 15 - Location of Hot Standby Power Module LED .........................................................................................21

 

Figure 16 - Location and Settings for Serial Port Protocols .......................................................................................23

 

Figure 17 - Connections to the Serial Module..............................................................................................................23

 

Figure 18 - Connections to the Alarm Module.............................................................................................................24

 

Figure 19 - Connections to the Video Control Module................................................................................................25

 

Figure 20 - Connections to the Titler Module ..............................................................................................................26

 

Figure 21 - Connections to the Network Module .........................................................................................................27

 

Figure 22 - Location of Network Cards in V1500CDU-CC Card Cage ....................................................................28

 

Figure 23 - Switches S1 and S2......................................................................................................................................28

 

Figure 24 - Example of the Netswitch-8 in a V1500 Networked System....................................................................31

 

Figure 25 - Basic Diagram of the V1500-KVM-R in a V1500 System .......................................................................32

 

Figure 26 - Partially Distributed Example System “A” ..............................................................................................34

 

Figure 27 - Partially Distributed System “B” ..............................................................................................................35

 

Figure 28 - Fully Distributed System “A” ....................................................................................................................36

 

Figure 29 - Fully Distributed System “B” ....................................................................................................................37

 

Figure 30 - Right Side of V1500CDU-CC Card Cage Rear Panel .............................................................................39

 

Figure 31 - Location of 9-Pin D-Shell Connector on Network Card..........................................................................42

 

 

Содержание NOVA 1500

Страница 1: ...t that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation This system has no...

Страница 2: ...This page is a placeholder...

Страница 3: ...tandby Configuration 12 Customized Configurations 14 Identifying Cards in the V1500CDU CC 15 V1500CDU Front Panel LEDs 19 Power Module 20 Serial Module 22 Alarm Module 24 Video Module 25 Titler Module...

Страница 4: ...Configurations 20 Figure 14 Inserting the Hot Standby Power Module 21 Figure 15 Location of Hot Standby Power Module LED 21 Figure 16 Location and Settings for Serial Port Protocols 23 Figure 17 Conn...

Страница 5: ...ments 6 Table 6 V1500CPU LED Indications 10 Table 7 Card Slot Order in Typical Configurations 11 Table 8 V1500CDU TYP HSB Configuration 12 Table 9 Color Codes for Extractor Tabs 15 Table 10 V1500CDU L...

Страница 6: ...EX Part No 1251 3273 01 Part No 1251 3273 01 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 NETSWITCH 8 Power HDD 3 3V V1500CPU ETHERNET 1 ETHERNET 2 Cat5e PATCH 6 10 cables Vicon product cod...

Страница 7: ...ces may be connected to the V1300X IA Part No 1251 3273 01 VICON KEYPAD VICON KEYPAD RD BK OR BL W BR YL G Ground N C N C N C RS 422CommandOut andRS 232TxD RS 422ResponseIn and RS 232RxD RS 422Respons...

Страница 8: ...Cat5e PATCH 6 10 cables Vicon product codes 7788 7789 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIA...

Страница 9: ...equipment and environment The V1500CPU connects to a PC monitor keyboard and mouse Application modules are installed into the V1500CDU card cage and allow for easy customization for a particular insta...

Страница 10: ...1500CDU H 1 7710 40 CDU hot standby configuration supports 2048 cameras 128 monitors time date titlers 32 keypads 512 receivers 512 alarms V1500CDU H 1 7710 50 CDU hot standby configuration supports 2...

Страница 11: ...1500CDU H 3 256 16 2 V1500CDU 4 and V1500CDU H 4 512 32 0 V1500CDU 5 and V1500CDU H 5 768 16 0 The maximum number of CCTV equipment that may be connected in one V1500 system is listed in Table 3 Note...

Страница 12: ...lation of two of each application card type Ethernet LAN V1400X IDL VICON CDU POWER 1 2 3 4 5 6 7 8 9 10 SWITCH V1400X IDL V1400X IDL VIDEO SWITCHER MATRIX VIDEO SWITCHER MATRIX SURVEYOR DOME CAMERA 2...

Страница 13: ...ique If the V1500CDU IP address scheme of 192 168 xxx yyy is not compatible with other devices then you must perform a procedure discussed in the Reference chapter to override the V1500 IP address pre...

Страница 14: ...cal V1500CDU with the following specifications 128 monitors connected to the video control and titler application cards 512 alarms on 2 alarm ports two serial cards each with 1 keypad and 1 receiver p...

Страница 15: ...H 3 V1500CDU H 4 V1500CDU H 5 The hot standby card cage contains a backup or hot standby card for each network parallel and serial card in the card cage This configuration is discussed in depth in the...

Страница 16: ...e warranty Power HDD 3 3V POWER RESET V1500CPU Front Panel 115 V1500CPU Rear Panel Figure 3 V1500CPU Front and Rear Panels As shown in Figure 4 the V1500CPU is usually connected to the V1500CDU throug...

Страница 17: ...following figure This step is not required on later production units Perform the following procedure to shut down the unit 1 Select the Shutdown option from the Windows Start Menu 2 The system will s...

Страница 18: ...es depends upon your system needs For example you may need a card cage that is fully populated with serial modules The various modules and accessories are listed in the Introduction section The most c...

Страница 19: ...detailed connection information and refer to this figure for a system overview SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 TDT CONTROL PORT 2 VIDEO CONT ROL PORT 1 VIDEO IN ALARM CONTROL P...

Страница 20: ...to the concepts in this section refer to Hot Standby Overview POWER POWER 1 2 OPERATIONAL ACTIVE Front Panel for Hot Standby Configuration ALARM CONTROL PORT 2 ALARM CONTROL PORT 1 ETHERNET 1 ETHERNE...

Страница 21: ...NET 1 ETHERNET 2 SERIAL PORT 2 SERIAL PORT 1 VICON CDU POWER 1 2 3 4 5 6 7 8 9 10 SWITCH V1400X IDL SURVEYOR DOME CAMERA V1311RB 2WA VICON CDU POWER 1 2 3 4 5 6 7 8 9 10 SWITCH V1400X IDL SURVEYOR DOM...

Страница 22: ...be used SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PORT 1 SERIAL PORT 2 SERIAL PO...

Страница 23: ...rchased the hot standby or typical configurations use the tables in the preceding sections to document the card types on the card label Also refer to the Network Neighborhood card descriptions as disc...

Страница 24: ...ARALLEL PARALLEL SERIAL PORT 1 SERIAL PORT 1 1 16 ALARM INPUTS 1 256 257 512 257 512 ALARM PORT 1 ALARM PORT 2 PARALLEL SERIAL SERIAL Host 1 SERIAL PORT 2 RS232 Monitors 1 64 Monitors 65 128 1 256 Key...

Страница 25: ...SLOT Hosts Keypads Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 1 1 16 257 512 1 256 V1500CDU H 2 PC 7710 20 SLOT Hosts Receivers Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 17...

Страница 26: ...Port 1 Port 2 Port 1 17 32 1 16 257 512 1 256 V1500CDU H 5 PC 7710 50 SLOT Keypads Receivers Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 Port 2 Port 1 1 16 513 768 257 512 1 256 11 12 backup 9 10 backup...

Страница 27: ...er or card failed Green Card successfully detects the appropriate interface and receives appropriate information from the V1500CPU Card does not detect adapter interface Card does not receive appropri...

Страница 28: ...second power module However dangerous voltages are present in the card cage and care should be taken to prevent injury and equipment damage Also take proper precautions to prevent static discharge 1...

Страница 29: ...3 00 4 Remove the lock washer which is the smaller of the two types of washers and thread it onto the screw 5 Place the flat washer behind the lock washer and use a Phillips head screwdriver to attach...

Страница 30: ...6 and V1500CDU H 1 card slots 7 8 RS 422 Receiver RS 422 Receiver V1500CDU 1 card slot 7 and V1500CDU H 1 card slots 9 10 RS 422 Keypad RS 232 Host PC V1500CDU 2 card slot 6 and V1500CDU H 2 card slot...

Страница 31: ...ts the figure below is only an example VICON CDU POWER 1 2 3 4 5 6 7 8 9 10 SWITCH V1400X IDL V1500CDU SER SERIAL PORT 1 SERIAL PORT 2 RD BK OR BL W BR YL G Ground N C N C N C RS 422CommandOut andRS 2...

Страница 32: ...o port 2 and the V1300X IA is connected to port 1 You may connect either XIA device to either port or the same type of XIA device to both ports Note Alarm port 1 is always used for alarms 1 256 and po...

Страница 33: ...le 25 pin male male 6 feet Used to make connections between the application module and the appropriate device 2 1251 3271 01 Note Port 1 is used for monitors 1 64 and port 2 is for 65 128 V1500CDU VID...

Страница 34: ...us section Note Port 1 is used for monitors 1 64 and port 2 is for 65 128 TDT CONTROL PORT 1 TDT CONTROL PORT 2 V1300X TCC Master Unit VICON V1300X TCC V1300X TCC Slave Unit VICON V1300X TCC VICON V13...

Страница 35: ...market Refer to the documentation provided with the hub for connection information Video is not transmitted on the Ethernet cable Standard video transmission media is required NETSWITCH 8 NETSWITCH 8...

Страница 36: ...S1 and S2 4 The IP address format is four sets of numbers separated by periods and each set of numbers must be in the range of 0 to 255 For V1500CDUs the IP address is 192 168 xxx yyy where xxx and y...

Страница 37: ...que If you are on a WAN and the V1500CDU IP address scheme of 192 168 xxx yyy is not compatible with other devices then you must perform a procedure discussed in the Reference chapter to override the...

Страница 38: ...8 X X X 124 X X X X X 210 X X X X 39 X X X X 125 X X X X X X 211 X X X X X 40 X X 126 X X X X X X 212 X X X X 41 X X X 127 X X X X X X X 213 X X X X X 42 X X X 128 X 214 X X X X X 43 X X X X 129 X X 2...

Страница 39: ...allows high speed connections at either 10BASE T or 100BASE TX making it ideal for connecting to the V1500 system Because of connection and setup complexity network switchers hubs and routers typicall...

Страница 40: ...GA cable set is required for each device connected to a KVM switch This cable set may be purchased separately from Vicon Note This figure below is meant to give a simple visual overview of the KVM swi...

Страница 41: ...rom a fully distributed configuration Though not discussed in detail here you may refer to Matrix66 Instruction Manual X824 for connection details the eight wires mentioned in the figure route video f...

Страница 42: ...ER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680SCC V1500 VICON V1500 1 2 POWER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680SCC V...

Страница 43: ...POWER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680SCC V1500 VICON V1500 1 2 POWER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680S...

Страница 44: ...of the system is compromised if one Matrix66 fails harder to troubleshoot all components behind a failed Matrix66 also appear to have failed VICON V1300X TCC V1300X TCC VICON VICON V1300X TCC V1300X...

Страница 45: ...ER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680SCC V1500 VICON V1500 1 2 POWER POWER OPERATIONAL ACTIVE VIDEO SWITCHER MATRIX VICON ON OFF KEYBOARD POWER V6680SCC V...

Страница 46: ...nd no display on my monitor There are two power switches on the V1500CPU With the power cable properly connected to a power source you must turn on the switch on the rear panel of the V1500CPU and the...

Страница 47: ...the sealed storage container in a location where the temperature is maintained between 32 to 113 F 0 to 45 C Reference Coaxial Cable Recommendations Caution Careful selection of proper cable is essen...

Страница 48: ...able picture 1100 350 1500 450 2400 750 Clean picture 820 250 1000 300 1600 500 Best picture 400 120 530 160 820 250 For longer cable runs use a Vicon Video Amplifier to obtain a suitable picture Twis...

Страница 49: ...panel of the V1500CDU card cage and locate Ethernet Card 1 on the card slot label using precautions to prevent injury to yourself and equipment as dangerous voltages exist in the card cage Also take c...

Страница 50: ...plete text is listed in the following steps 8 The current network parameters such as the IP address are shown at the top of the information under the Build Time As shown on the screen press any key wi...

Страница 51: ...4 3 kg cal min max Note These figures represent the conversion of 100 of the electrical energy to heat Actual percentage of the heat generated will be less and will vary from product to product These...

Страница 52: ...ors for easy card mounting Connector modules are accessible through the rear and independently serviceable Dimensions Width 19 0 in 483 mm Height 5 25 in 133 mm Weight 21 2 lb 9 6 kg Construction Shee...

Страница 53: ...ope contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and...

Страница 54: ...Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32...

Отзывы: