9

All covers: Machine washable. Covers comply 
with CAL117.

PRECAUTIONS AND SAFETY 
INSTRUCTIONS 

A Vicair wheelchair seat cushion may only be 
used as a wheelchair seat cushion. The use of 
this product in any other way, is considered to be 
misuse. Vicair B.V. cannot be held responsible 
for damage caused by misuse, improper use or 
negligence. Make sure that you read and 
understand this manual completely. 

Warning!

 Vicair B.V. recommends to install the 

Vicair Vector O2 under direct supervision of a 
therapist or Assistive Technology Professional. 

Warning! 

Your tailbone and pelvic bones should 

not touch the bottom of the cushion. Checking 
for “bottoming out” should be done during first 
use and after adjustments to the cushion filling. 

Warning!

 Check your skin regularly for redness, 

especially during the first few days. If redness 
occurs and does not disappear after 15 minutes, 
consult your therapist or Assistive Technology 
Professional. 

Warning!

 Vicair B.V. recommends to adjust the 

filling grade under the direct supervision of your 
therapist or Assistive Technology Professional. 

Warning!

 In case of soiling with body fluids, and 

when transferring the product to another user, 
the product must be disinfected to avoid cross 
contamination. 

Warning!

 Every three months, check the product 

for wear and deflated cells. In case of serious 
damage, or a large number of deflated cells, do 
not continue to use the product. Consult your 
Assistive Technology Professional.

Caution!

 Do not use or leave the product close 

to a naked flame or a high temperature heat 
source. 

Caution!

 Do not steam clean or autoclave the 

product. The product cannot withstand 

excessive heat or pressure. When the given 
cleaning instructions are not followed, it is very 
likely that the product and/or the product’s cover 
will age more rapidly. 

Caution!

 Do not use aggressive or abrasive 

cleaners, or sharp objects to clean the cushion. 

Caution!

 Do not place the topside of the Vicair 

O2 cushion against the glass of the washer door.

Caution! 

Make sure the cushion cannot interfere 

with the wheel spokes.

Caution! 

Excessive washing may influence the 

aging of this product.

Notice!

 Filling grade may slightly deviate from 

default (see product label).

INSTALLATION

Warning! 

Vicair B.V. recommends to install the 

Vicair Vector O2 under direct supervision of a 
therapist or Assistive Technology Professional. 

Caution! 

Make sure the cushion cannot interfere 

with the wheel spokes. 

Notice! 

Always use cushion with cover. 

Notice! 

Make sure that the wheelchair seat is 

clean and degreased. 

Tip: 

When you prefer not to use the hook and 

loop, you can remove the hook strips. Note that 
the loop strips confected to the bottom of the 
cushion and/or cushion cover cannot be 
removed.

Perform the following steps when installing the 
Vicair Vector O2

•  Check cushion size. Width of the cushion and 

seat should match. When the cushion rests 
against arm supports or side-guards, the width 
may be up to 2,5 cm (1”) wider. Depth of the 
cushion and seat should match. 

•  Check if the size of the cover matches the 

size of the cushion.

•  Remove the hook strips from the bottom of 

the cushion. Note that the loop strips 
confected to the bottom of the cushion 

Содержание Active O2

Страница 1: ...USER MANUAL ...

Страница 2: ...VICAIR ADJUSTER O2 3 VICAIR VECTOR O2 8 VICAIR ACTIVE O2 13 ...

Страница 3: ...e injuries and to provide comfort and stable body support It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A A C B D A Cushion cover B Cushion C SmartCells D User manual GENERAL PRODUCT SPECIFICATIONS Product name Vicair Adjuster O2 Manufactured by Vicair B V The Netherl...

Страница 4: ... naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When the given cleaning instructions are not followed it is very likely that the product and or the product s cover will age more rapidlyly Caution Do not use aggressive or abrasive cleaners or sharp objects to clean the cushion Caution Do not p...

Страница 5: ...on if bottoming out occurs In most cases adjusting the filling grade of the compartments will solve the problem USE Checking for redness of the skin Warning Check your skin regularly for redness especially during the first few days If redness occurs and does not disappear after 15 minutes consult your therapist or Assistive Technology Professional Adjusting the filling grade Warning Vicair B V rec...

Страница 6: ...The product has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Replacing the cushion cover Under normal use Vicair B V recommends to replace the cushion cover every year Replacement covers can be purchased separately Disposal The disp...

Страница 7: ... compartments outwards to make sure the spray gets into the gaps REPORTING OF SERIOUS INCIDENTS Serous incidents from use of Vicair products should be reported to the manufacturer and the relevant competent authority WARRANTY Please see www vicair com for complete information on warranty processes terms and conditions Vicair B V offers a limited warranty against defects in workmanship and material...

Страница 8: ... body posture and prevent pressure injuries It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A Cushion cover B Cushion C SmartCellsTM placed in 9 compartments D User manual GENERAL PRODUCT SPECIFICATIONS Product name Vicair Vector O2 Manufactured by Vicair B V The Nether...

Страница 9: ... the product close to a naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When the given cleaning instructions are not followed it is very likely that the product and or the product s cover will age more rapidly Caution Do not use aggressive or abrasive cleaners or sharp objects to clean the cus...

Страница 10: ...he wheelchair seat Do not use the cushion if bottoming out occurs In most cases adjusting the filling grade of the compartments will solve the problem USE Checking for redness of the skin Warning Check your skin regularly for redness especially during the first few days If redness occurs and does not disappear after 15 minutes consult your therapist or Assistive Technology Professional Adjusting t...

Страница 11: ...t has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Expected lifetime The expected lifetime of this product is five years when used in accordance with the safety instructions maintenance intervals and correct use stated in this manua...

Страница 12: ...erably use an anti bacterial detergent After washing spray your cushion and cover with a disinfectant Bend compartments outwards to make sure the spray gets into the gaps REPORTING OF SERIOUS INCIDENTS Serous incidents from use of Vicair products should be reported to the manufacturer and the relevant competent authority WARRANTY Please see www vicair com for complete information on warranty proce...

Страница 13: ...take out the foam inlay INDICATIONS The Vicair Active O2 allows easy transfers and provides stable body support comfort and pressure ulcer prevention It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A B C D E A Foam inlay with fluid resistant foam inlay liner placed in f...

Страница 14: ... check the product for wear and deflated cells In case of serious damage or a large number of deflated cells do not continue to use the product Consult your Assistive Technology Professional Caution Do not use or leave the product close to a naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When...

Страница 15: ...sk your therapist or Assistive Technology Professional to check if your lowest bony prominences are supported by at least 2 5 cm 1 of SmartCells This prevents your seat bones from touching the wheelchair seat Do not use the cushion if bottoming out occurs In most cases adjusting the filling grade of the SmartCell liners will solve the problem USE Checking for redness of the skin Warning Check your...

Страница 16: ...used The product has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Expected lifetime The expected lifetime of this product is five years when used in accordance with the safety instructions maintenance intervals and correct use state...

Страница 17: ... at 60 C Follow the washing instructions on the label attached to the inside of the liner 1 2 3 4 5 Cleaning the foam Take the foam out of the foam inlay liner and clean it by using a disinfectant spray 6 7 8 Disinfecting your Vicair Active O2 Warning In case of soiling with body fluids and when transferring the product to another user the product must be disinfected to avoid cross contamination C...

Страница 18: ...anship and materials provided the product has been used normally Any damage arising from abnormal use or caused by improper handling cleaning or negligence is excluded from this warranty Warranty period From original date of purchase 24 months The SmartCells in this Vicair O2 cushion have a lifelong warranty period Should a defect in materials or workmanship occur within the above mentioned warran...

Страница 19: ......

Страница 20: ...04 2022 Vicair B V Bruynvisweg 5 1531 AX Wormer The Netherlands info vicair com www vicair com 8 717261 041803 Vicair Adjuster O2 8 717261 037660 Vicair Vector O2 8 717261 058559 Vicair Active O2 8 717261 058566 ...

Отзывы: