Daily fluff-up 

Vicair B.V. recommends to fluff-up your Vicair 
cushion before use on a daily basis. 

Use of Vicair seat cushions in motor vehicles 

Whenever possible, transfer out of the 
wheelchair and into a car manufactured-
installed vehicle seat without the cushion, and 
use the vehicle's crash-tested occupant restraint 
system.
As an alternative for your Vicair wheelchair 
cushion, the Vicair Allrounder O2 (which can be 
fastened to the user's body) can be used if you 
require additional protection in a manufacturer-
installed vehicle seat during transportation. 
When the wheelchair is used as the vehicle seat, 
the applicable rules and regulations with regard 
to securing the wheelchair and the wheelchair 
user during transport should be followed.
There is no data available about the influence 
on safety of a Vicair wheelchair cushion used in 
a crash-tested wheelchair.  

Expected lifetime

The expected lifetime of this product is five 
years when used in accordance with the safety 
instructions, maintenance intervals and correct 
use, stated in this manual.
The effective lietime can vary according to 
frequency and intensity of use.

Re-use - Transferring the product to another 
user 

The product is suitable for repeated use. 
The number of times it can be used depends on 
how often and in which way the product is used. 
The product has to be thoroughly cleaned and 
disinfected, before another person is allowed to 
use the it. See chapter ‘Maintenance and 
cleaning’ for instructions. 

Notice!

 Make sure the product is correctly 

adjusted to the other person.

Replacing the cushion cover 

Under normal use, Vicair B.V. recommends to 
replace the cushion cover every year. 
Replacement covers can be purchased 
separately.

Disposal 

The disposal and recycling of used devices and 
packaging must comply with the applicable legal 
regulation. Ensure the product is cleaned prior 
to disposal to avoid any risk of contamination.

MAINTENANCE AND CLEANING

Warning! 

Every three months, check the product 

for wear and deflated cells. In case of serious 
damage, or a large number of deflated cells, do 
not continue to use the product. Consult your 
Assistive Technology Professional. 

Caution!

 Do not steam clean or autoclave the 

product. It cannot withstand excessive heat or 
pressure. When the given cleaning instructions 
are not followed, it is very likely that the product 
will age more rapidlyly. 

Caution!

 Do not use aggressive or abrasive 

cleaners, or sharp objects to clean the cushion.

Caution!

 Do not place the topside of the Vicair 

O2 cushion against the glass of the washer door.

Caution! 

Excessive washing may influence the 

aging of this product.

Cleaning the Vicair Adjuster O2

• 

Cleaning the Vicair Adjuster O2 cushion 
cover 

The cushion cover can be machine washed. 
Follow the washing instructions on the label 
attached to the inside of the cover.  
(60 °C=140 °F) 

1 2 3 4 5

Содержание Active O2

Страница 1: ...USER MANUAL ...

Страница 2: ...VICAIR ADJUSTER O2 3 VICAIR VECTOR O2 8 VICAIR ACTIVE O2 13 ...

Страница 3: ...e injuries and to provide comfort and stable body support It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A A C B D A Cushion cover B Cushion C SmartCells D User manual GENERAL PRODUCT SPECIFICATIONS Product name Vicair Adjuster O2 Manufactured by Vicair B V The Netherl...

Страница 4: ... naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When the given cleaning instructions are not followed it is very likely that the product and or the product s cover will age more rapidlyly Caution Do not use aggressive or abrasive cleaners or sharp objects to clean the cushion Caution Do not p...

Страница 5: ...on if bottoming out occurs In most cases adjusting the filling grade of the compartments will solve the problem USE Checking for redness of the skin Warning Check your skin regularly for redness especially during the first few days If redness occurs and does not disappear after 15 minutes consult your therapist or Assistive Technology Professional Adjusting the filling grade Warning Vicair B V rec...

Страница 6: ...The product has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Replacing the cushion cover Under normal use Vicair B V recommends to replace the cushion cover every year Replacement covers can be purchased separately Disposal The disp...

Страница 7: ... compartments outwards to make sure the spray gets into the gaps REPORTING OF SERIOUS INCIDENTS Serous incidents from use of Vicair products should be reported to the manufacturer and the relevant competent authority WARRANTY Please see www vicair com for complete information on warranty processes terms and conditions Vicair B V offers a limited warranty against defects in workmanship and material...

Страница 8: ... body posture and prevent pressure injuries It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A Cushion cover B Cushion C SmartCellsTM placed in 9 compartments D User manual GENERAL PRODUCT SPECIFICATIONS Product name Vicair Vector O2 Manufactured by Vicair B V The Nether...

Страница 9: ... the product close to a naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When the given cleaning instructions are not followed it is very likely that the product and or the product s cover will age more rapidly Caution Do not use aggressive or abrasive cleaners or sharp objects to clean the cus...

Страница 10: ...he wheelchair seat Do not use the cushion if bottoming out occurs In most cases adjusting the filling grade of the compartments will solve the problem USE Checking for redness of the skin Warning Check your skin regularly for redness especially during the first few days If redness occurs and does not disappear after 15 minutes consult your therapist or Assistive Technology Professional Adjusting t...

Страница 11: ...t has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Expected lifetime The expected lifetime of this product is five years when used in accordance with the safety instructions maintenance intervals and correct use stated in this manua...

Страница 12: ...erably use an anti bacterial detergent After washing spray your cushion and cover with a disinfectant Bend compartments outwards to make sure the spray gets into the gaps REPORTING OF SERIOUS INCIDENTS Serous incidents from use of Vicair products should be reported to the manufacturer and the relevant competent authority WARRANTY Please see www vicair com for complete information on warranty proce...

Страница 13: ...take out the foam inlay INDICATIONS The Vicair Active O2 allows easy transfers and provides stable body support comfort and pressure ulcer prevention It is also a high performance addition to a pressure ulcer treatment plan stage I IV CONTRAINDICATIONS When used as intended there are no known contraindications MAIN COMPONENTS A B C D E A Foam inlay with fluid resistant foam inlay liner placed in f...

Страница 14: ... check the product for wear and deflated cells In case of serious damage or a large number of deflated cells do not continue to use the product Consult your Assistive Technology Professional Caution Do not use or leave the product close to a naked flame or a high temperature heat source Caution Do not steam clean or autoclave the product The product cannot withstand excessive heat or pressure When...

Страница 15: ...sk your therapist or Assistive Technology Professional to check if your lowest bony prominences are supported by at least 2 5 cm 1 of SmartCells This prevents your seat bones from touching the wheelchair seat Do not use the cushion if bottoming out occurs In most cases adjusting the filling grade of the SmartCell liners will solve the problem USE Checking for redness of the skin Warning Check your...

Страница 16: ...used The product has to be thoroughly cleaned and disinfected before another person is allowed to use the it See chapter Maintenance and cleaning for instructions Notice Make sure the product is correctly adjusted to the other person Expected lifetime The expected lifetime of this product is five years when used in accordance with the safety instructions maintenance intervals and correct use state...

Страница 17: ... at 60 C Follow the washing instructions on the label attached to the inside of the liner 1 2 3 4 5 Cleaning the foam Take the foam out of the foam inlay liner and clean it by using a disinfectant spray 6 7 8 Disinfecting your Vicair Active O2 Warning In case of soiling with body fluids and when transferring the product to another user the product must be disinfected to avoid cross contamination C...

Страница 18: ...anship and materials provided the product has been used normally Any damage arising from abnormal use or caused by improper handling cleaning or negligence is excluded from this warranty Warranty period From original date of purchase 24 months The SmartCells in this Vicair O2 cushion have a lifelong warranty period Should a defect in materials or workmanship occur within the above mentioned warran...

Страница 19: ......

Страница 20: ...04 2022 Vicair B V Bruynvisweg 5 1531 AX Wormer The Netherlands info vicair com www vicair com 8 717261 041803 Vicair Adjuster O2 8 717261 037660 Vicair Vector O2 8 717261 058559 Vicair Active O2 8 717261 058566 ...

Отзывы: