VibroSystM 797L Скачать руководство пользователя страница 5

Copyright © VibroSystM Inc., 2006

4

  797L Piezoelectric Accelerometer and Cable_Installation - Rev. 1

Step 2) Mounting the accelerometer

1. Mount the accelerometer using a torque screwdriver for tightening. The supplied captive screw should be

torqued to a nominal value of 3,3895 Nm (30 lb-in). Under-torquing the accelerometer reduces the
stiffness of the coupling, while over-torquing can cause permanent thread damage. 

Note:

 Use Loctite 222 thread adhesive for better results.

Installation on an insulated bearing

1.  Shown here is an alternate mounting

method. The sensor is installed on an
insulating block.

If the sensor is installed on an insulated bearing, special care must be taken to
preserve the insulation of the bearing.

The most widely recommended mounting method consists in placing a 0.063 in.
thick mica sheet between mounting bracket and bearing, and using non-metallic
screws.

Содержание 797L

Страница 1: ......

Страница 2: ...Manual_Table of Contents Rev 1 797L Piezoelectric Accelerometer Installation Manual Product 9400 09M3A 101 This manual divides into the following sections Section 1 Installation of the Piezoelectric...

Страница 3: ...ications will require that the accelerometer be mounted on the same support structure and in the same axis as the proximity probe The 797L piezoelectric accelerometer is shipped with a captive screw f...

Страница 4: ...e great care in handling the Model 797L accelerometer NEVER DROP it or hit it against a solid object Keep it stored in its box until you have surveyed and prepared the location suitable for installati...

Страница 5: ...s of the coupling while over torquing can cause permanent thread damage Note Use Loctite 222 thread adhesive for better results Installation on an insulated bearing 1 Shown here is an alternate mounti...

Страница 6: ...006 5 797L Piezoelectric Accelerometer and Cable_Installation Rev 1 2 Glue is applied on the block and insulated surface 3 The sensor is held in place until the glue has set The sensor can be mounted...

Страница 7: ...n a protective conduit Step 1 Installation of the cable 1 Determine the run of the cable keeping in mind that its maximum length is 100 m 330 ft 2 Unroll the protective conduit following the planned c...

Страница 8: ...monitored end Figure 4 Insulated bearing Step 3 Verification 1 Verify that the 797L piezoelectric accelerometer is functioning well measure the voltage at the output of the accelerometer e g between b...

Страница 9: ......

Отзывы: