56
OLP-85/OLP-85P
8 P
ROBE
/PCM O
PERATION
C
ONFIGURING
THE
D
IGITAL
P
ROBE
1.
Click on the
[
G
]
key to save a JPG file of the test result in the
currently active group on the OLP-85.
2.
On the edition keypad, enter the name of the JPG file.
3.
Press Enter to validate and save the document.
The file is saved in the current active group directory on the OLP-85.
Freeze mode
Once the image is acceptable (sharpness, luminosity are tuned
correctly), you may freeze the picture. This feature allows you to
store the resulting picture in order to compare it later to others
or save it in a file. In Freeze Mode the picture has a blue colored
frame.
NOTE:
Freezing a result does not store the picture in a file (see
). The result will be lost if the instrument is
shut off.
Depending on the QuickCapture™ key setting, this key allows
you to freeze the picture or to start a test.
Profile
1.
Press the
[
A
]
key.
2.
Tap the
[
Profile
]
button.
3.
Tap the Profile which will be used for the test of the fiber
connector:
– E2000: Pass/Fail criteria for precision metal ferrule connec
-
tors.
– Ribbon_: Pass/Fail criteria for single-mode and multi-mode
connectors from IEC 61300-3-35 standard.
– SM-UPC: Pass/Fail criteria for single-mode UPC connectors
from IEC 61300-3-35 standard.
– SM-APC: Pass/Fail criteria for single-mode APC connectors
from IEC 61300-3-35 standard.
– SM_PC: Pass/Fail criteria for single-mode PC connectors
from IEC 61300-3-35 standard.
– MM_: Pass/Fail criteria for multi-mode connectors from IEC
61300-3-35 standard.
– SFP_: Pass/Fail criteria for small form-factor pluggables.
Profiles contain the analysis parameters from which Pass/Fail
criteria are determined.