ONX-220 User's Guide
22135173, Rev. 000
June 2020
92
Chapter
4 CATV Testing
Results
For a detailed discussion of the results produced by this test, see
.
Additional notes for leakage monitoring in the home
y
Enter home and walk through each room with RF cabling. Include basements,
crawl spaces, attics and rooms with CPE devices.
y
If leak above squelch setting is detected, meter emits audible tone relative to
detected leak size and displays leak level.
y
Once leak is detected, move meter side-to-side through room to determine
direction of highest leak level. When maximum leak level is determined, the leak
source has been located:
y
If leak level is too high, remove dual band antenna and attach near field
probe.
y
If leak is too high with near field probe, change transmitter to low level
mode (+40 dBmV/+100 dBμV) and re-check.
y
Repair, tighten or replace leaking component.
y
Recheck room to ensure all leak sources have been addressed and repaired.
y
Move to remaining rooms to continue locating leaks.
Содержание ONX-220
Страница 1: ...ONX 220 User s Guide ...
Страница 8: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 8 ...
Страница 34: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 34 Chapter 1 Quick Tour ...
Страница 78: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 78 Chapter 3 Menus and Workflow ...
Страница 98: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 98 Chapter 5 Ethernet Testing ...
Страница 170: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 170 Chapter 10 Using the OneExpert with a Mobile Device ...
Страница 198: ...ONX 220 User s Guide 22135173 Rev 000 June 2020 198 Chapter 11 Test Results ...
Страница 211: ......