DSP TDR Quick Start Guide
22134505, Rev. 000
July 2019
8
9. Adjustments can be made to the following;
Avg
– 1–100 samples
S.Ref
– Ref +1 to 2000
V.Zoom
– 0 to Ref-1
Sensitivity
– Low (200
Ω
), Med (60
Ω
) or High (50
Ω
)
Zoom
– Allows for adjustments to zoom
Zoom in
– Zooms in on center of screen
Zoom out
– Zooms out from center of screen
Full
– Zooms out to preset read distance setting
To Markers
– Zooms to fill screen from marker to marker
Center Marker
– moves marker and trace to center of screen
Lock view range
– Locks viewing distance to start and stop distances currently
set
Start distance
– Sets the viewing distance at the left edge of screen
Stop distance
– Sets the viewing distance at the right edge of screen
Purple marker
– Movable marker that can be placed at user-defined distance
Blue marker
– Movable marker that can be placed at user-defined distance. Marker
moves to event location when selecting an event from the event list.
Trace
– Live or single trace
Function menu
Screen Capture
– Stores a PNG file
of current screen display
Save Data Log
– Stores all TDR
data needed to rebuild display in
StrataSync
Hide Marker Bar
– Removes marker
info from bottom of display screen
Display Raw/Events
– Used to
toggle display from Raw view to
Events view
Enable/Disable Auto Range
–
Enabled causes auto range to zoom to first event from start
Show Events List
– Enables pop-up screen with events list showing events and
distance
Recall Trace
– Recalls and displays a previously saved TDR trace
Содержание DSP TDR
Страница 1: ...DSP TDR Quick Start Guide ...