Servicing
44
11.5 Pressure Losses of Chimney Flue Elements in Case of NAOS K4 Boiler Usage
Maximal pressure of fan 150Pa
Multi-piece Chimney Flue - Burnt Gases
Code
DN
Name
Loss in Pa
PPSB48
80
Angle piece 45°
1.1
PPSB98
80
Angle piece 87°
1.7
PPRM18
80
Tube 1m
3.4
PPSAS8
80
Chimney plastic head - starr (a set]
2.5
Multi Piece Chimney Flue -
Suction
Code
DN
Name
Loss in Pa
PPSB48
80
Angle piece 45°
0.8
PPSB98
80
Angle piece 87°
1.2
PPRM18
80
Tube 1m
2.5
Concentric Chimney Flue
Code
DN
Name
Loss in Pa
LPBK45
60/100
Angle piece 45°
5.3
LPBK95
60/100
Angle piece 87°
7.5
LPRK15
60/100
Tube 1m
21.9
LPZTK5
60/100
LIK T-piece for air inlet
5
APASK5
60/100
LIK tube piece for façade chimney flue
10.5
DPDS45
60/100
Roof extension (a set)
29.8
LPBK48
80/125
Angle piece 45°
1.5
LPBK98
80/125
Angle piece 87°
2.1
LPRK18
80/125
Tube 1m
5.4
LPZTK8
80/125
LIK T-piece for air inlet
1.5
APASK8
80/125
LIK tube piece for façade chimney flue
3.5
DPDS48
80/125
Roof extension (a set)
9.1
LPKK01
60/100-80/125
LIK boiler reducer
2