EN
BL530 PH/RX DOSAGE SYSTEM |
13
UV-C and Pool equipment
Warning!
The complete list of parameters can be accessed only from
the “Advanced Configuration” menu, while the “Standard Configuration”
mode allows to modify only the parameters that are not protected
by password (highlighted in bold in the table above).
PARAMETER 01 FUNCTIONING TYPE OF THE PUMP 1
This parameter allows to set the functioning type of pump 1, typically used for the pH control.
PARAMETER 02 SET-POINT PUMP 1
This parameter allows to enter the desired pH value for the swimming pool water. The dosing pump
is activated / de-activated to reach this value and keep it constant.
PARAMETER 03 HYSTERESIS PUMP 1
This parameter is sued to adjust the functioning hysteresis of pump 1 around the threshold set in
P02. It is recommended to set a narrow window in case of ON-OFF mode, while for proportional
mode it is advisable to set a window of at least points.
PARAMETER 04 DOSAGE DIRECTION OF PUMP 1
This parameter allows to set the dosage direction. The choice depends on the product dosed to
adjust the pH level: if you dose an acid, set this parameter to “Acidification”, while if you dose a base
set “Alkalinisation”.
PARAMETER 05 TIME BASE FOR PUMP 1
If the pump is configured to ON-OFF mode, this parameter indicates a percentage of operation of
the pump, on a fixed time base of 100 seconds. 100% corresponds to pump always ON, while 5%
indicates that the pump is ON for 5% of time (=5 seconds) and OFF for the remaining 96% (=95
seconds). If the pump is configured for proportional operation, this parameter indicates the time
base of pump.
PARAMETER 06 FUNCTIONING TYPE OF THE PUMP 2
This parameter allows to set the functioning type of pump 2, typically used for
controlling the redox potential level. See description of parameter P01.
PARAMETER 07 SET-POINT PUMP 2
See parameter P02, but referred to redox measurements.
PARAMETER 08 HYSTERESIS PUMP 2
See parameter P03, but referred to redox measurements.