If the control panel temperature becomes too high (> 50 °C) due to a too high
ambient temperature, the bimetallic switch will be activated and the UV lamp will
switch off. If the bimetallic switch is activated, the UV lamp will be switched off
immediately.
The bimetallic switches has an automatic reset function, as soon as the bimetallic switch has cooled down
sufficiently (approximately 35 °C (control panel), the contact will automatically close again.
4.5.2.2 Timer operation
On the front of the control is a sticker with the VGE logo, a push button and an LED
indicator.
If the UV system is switched on, the program will check itself. The LED will flash red rapidly for
approximately 1 second. After this the LED lights up green, blinks green or lights up red. This depends on
the number of hours that the system has already been in operation.
When the UV lamp is first switched on or after the "reset" function is used, the internal operating hour
counter has a value of 9,000 hours. The number of operating hours is adjusted to the lamp in your device.
Each UV lamp has a maximum number of operating hours, during which the lamp guarantees optimum
disinfection. If the number of operating hours of the UV lamp has been reached, it must be replaced. When
the system is switched off or after a power failure, the system will remember the remaining number of
operating hours. After switching on, the system will continue to count from the moment it was stopped.
Operating hours counter status:
- Green burn: the UV-C lamp burns within the normal lifespan;
- Flashing green: the UV-C lamp needs replacement within 500 hours;
- Red light: the UV-C lamp must be replaced as soon as possible.
4.5.2.3 Resetting the hours counter
After replacing the UV lamp, the operating hours counter must also be reset. A reset resets the operating
hours counter to 9,000 hours.
Resetting the operating hours counter:
- Hold down the push button;
- The LED will flash quickly and then turn green. This takes a total of approximately 5 seconds;
- As soon as the hour counter lights up green, you can release the push button;
- The operation hours counter will start a new cycle.