Clip Plate
Notch
Disassemble the Camera
2.
Pry the mounting base to remove the mounting
base with the camera body.
3.
Attach the drill template (supplied) to the place
where you want to fix the camera, and then drill the
screw holes and the cable hole in the ceiling
according to the drill template.
Drill Template
4.
Route the cables through the cable hole.
5.
Secure the mounting base to the ceiling with the
supplied screws. (You can drill the expansion screws
first or drill the fixing screws directly)
Expansion Screw
Fixing Screw
Fix the Mounting Base to the Ceiling
6.
Route the cables. Connect the power cord and
network cable.
7.
Secure the camera to the mounting base.
Secure the Camera
8.
Adjust the camera according to 0 to get an optimum
angle.
1).
Hold the camera body and rotate the enclosure
to adjust the pan angle [0° to 360°].
2).
Move the camera body up and down to adjust
the tilt angle [0° to 75°].
3).
Rotate the camera body to adjust the Loosen
No.3 adjusting azimuth angle [0° to 360°].