Continue to assemble chimney sections as 

outlined  above,  making  sure  that  both  the 

inner  and  outer  pipe  sections  are  locked 

together. 
When installing double wall snap-lock chimney 

together, it is important to assure joint between 

chimney sections is locked. Check by pulling 

chimney upward after locking. Chimney will not 

come apart if properly locked. It is not neces

-

sary to add screws to keep chimney together 

(exception, see Figure 12, page 8).

ADjUSTABLE FIRESTOP THIMBLE 

(FST-A)

The adjustable firestop thimble assembly (FST-A) 

is used to provide the necessary air space and 

clearance between the chimney pipe and insula

-

tion in the attic space of a manufactured home.
To  install  thimble  assembly,  determine  dis

-

tance between ceiling joist and roof framing. 

Attach adjustable thimble to firestop spacer so 

that assembly will cover the distance. Adjust

-

able thimble should be even with or above the 

roofline (see 

Accessories

, page 14, for thimble 

VenTing inSTallaTion

Continued

Thimble Extension 

(If Needed)

Roof Line

Adjustable Thimble

Existing 

Ceiling Frame

Firestop Spacer

Screws or Staples 

(Min. of 8)

Thimble (Open End)

12" 

Min.

Thimble 

(Closed End)

Firestop

Adapter Plate (If Needed)

Insulation 

Barrier

Screw Holes 

Provided 

for Thimble 

Firestop

Figure 8 - Attaching Firestop/Thimble 

Assembly to Ceiling

extensions  if  a  longer  thimble  is  needed). 

Sheet metal screws or staples may be used 

to attach thimble to firestop spacer.
An opening large enough to allow insertion of 

firestop thimble assembly will be required in 

the ceiling. Attach firestop/thimble assembly 

to ceiling/ceiling joist using screws or staples 

as shown in Figure 8. A minimum of 8 screws 

or staples should be used.
The  firestop  thimble  assembly  should  also 

be used where there is a cathedral ceiling, 

insulation barrier and roof, all in one assembly 

in a manufactured home (see Figure 8 and 

Figure 7). The FST-A thimble can be used in 

any one of three common ceiling pitches; flat, 

12"/96" and 30"/144".
An opening big enough to allow the insertion 

of  the  firestop  thimble  assembly  will  be  re

-

quired. This opening depends on the pitch of 

your ceiling. If your ceiling is a flat or 12"/96" 

pitch, you must use the adapter plate provided 

to  seal  unwanted  openings.  For  30"/144" 

pitch, discard adaptor. 
If adapter is needed, secure it onto firestop 

using holes provided (see Figure 9). The row 

of holes on sides of thimble is provided to allow 

for pitch variances. Position firestop assembly 

and thimble to desired angle and secure with 

screws provided. Insert thimble and firestop 

into prepared opening and secure to ceiling 

by nailing through firestop flanges. The thimble 

should  be  even  with  or  above  the  roofline. 

Thimble extensions are available (as an option) 

when required. See 

Accessories,

 page 14.

Figure 9 - Use a Firestop Thimble 

Assembly for Cathedral Ceiling, 

Insulation Barrier and Roof

12"/96" Pitch

30"/144" Pitch

7.13"

11.77"

144"

96"

12"

30"

Thimble

Adapter Plate 

(For Flat and 

12"/96" Pitch 

Ceilings Only)

Firestop

Use for 12"/96" 

Pitch Ceiling

Use for Flat 

Pitch Ceiling

Содержание 368STM-1

Страница 1: ...free log can only be installed in an aftermarket completion of sale not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes A...

Страница 2: ...or local distributor IMPORTANT Check HUD re quirementsbeforeinstallingthis fireplace Model 368STM is specifically designed for use in manufactured mobile homes This fireplace includes a manual contro...

Страница 3: ...ill make installation easier 4 An outside air kit is available with this fireplace see Outside Air Kit on page 5 WARNING Donotinstallthis appliance in a bedroom 24 37 1 2 20 1 2 10 1 4 53 1 2 17 1 2 4...

Страница 4: ...the full width and depth of fireplace 3 Set fireplace directly in front of opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if...

Страница 5: ...means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 3 WARNING Hearthextension is to be installed only a...

Страница 6: ...tion air is accessed through mobile home floor using air kit modelAK 6 or a side wall using air kit model AK 6WI see Accessories on page 14 CAUTION Combustion air inlet ducts shall not terminate in a...

Страница 7: ...mble to firestop spacer An opening large enough to allow insertion of firestop thimble assembly will be required in the ceiling Attach firestop thimble assembly to ceiling ceiling joist using screws o...

Страница 8: ...mum of 36 above high est point where it passes through roof 16 3 8 Min 48 3 cm 30 Min 76 cm 2 Min 5 1 cm 2 Min 5 1 cm 2 Min 5 1 cm Opening A PITCH SLOPE OPENING A MAX FLASHING MODE NO Flat 0 17 6F 8 0...

Страница 9: ...4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2...

Страница 10: ...ions with slip sections Note Storm collar is required but can be installed after home is sited Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Th...

Страница 11: ...al distance of 10 feet see Figure 19 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Foot Rule Chimney Support Bracket Kit CSK 8DM If exposed portion of chimney is greater than fiv...

Страница 12: ...nt free appliance available through your local distributor Use only a 1 2 black iron pipe and appropriate fittings When installing a gas line a shutoff valve designed for installation outside the appl...

Страница 13: ...place When fireplace is in operation doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created see Figure 23 A fireplace equipped with glass doors operates much differen...

Страница 14: ...ll to close and push to open Always open both handles before starting a fire This provides adequate outside combus tion air Close both handles when not in use to prevent cold air from entering the roo...

Страница 15: ...144 96 12 30 AccessorIES Continued SQUARE CHASE TOP TERMINATION ETL 8DM Optional OUtside air kit for side wall installation AK 6WI Hearth extension he 36 Thimble extensions TXL 8DM 43 TX 8DM 26 Vent...

Страница 16: ...have further questions about installation operation or troubleshooting If so contact Style Crest Inc at 1 800 231 4822 or write to Style Crest Service P O Box 19110 Wichita KS 67204 When calling or wr...

Отзывы: