Vexar 368STM-1 Скачать руководство пользователя страница 4

www.fmiproducts.com

56149J

4

MINIMUM CLEARANCE TO 

COMBUSTIBLES

Back and sides of fireplace 

1" minimum*

Floor** 

0" minimum

Wall to front of fireplace 

36" minimum

Perpendicular wall to opening  14" minimum
Top spacers 

0" minimum

Mantel clearances      see 

Mantels

, page 14

Chimney outer pipe surfaces  1" minimum

* Not required at nailing flanges
** See step 2 of 

Installing Fireplace

 WARNING: Do not pack re-

quired air spaces with insulation 

or other materials.

Minimum/Maximum Chimney Height

Minimum height of chimney, measured from 

base of fireplace to flue gas outlet of termina

-

tion, is 15 feet for straight flue and 16 feet for 

a flue with one elbow set. Maximum distance 

between elbows is 2 feet. For systems with 

2  elbow  sets,  minimum  height  is  25  feet. 

Maximum height of any system is 40 feet. This 

measurement  includes  fireplace,  chimney 

sections and height of termination assembly 

at  level  of  flue  gas  outlet  (see  Figure  15, 

page 10).

FRAMING

1.  Frame opening for fireplace using dimen

-

sions shown in Figure 1.

2.  If  fireplace  is  to  be  installed  directly  on 

carpeting, tile (other than ceramic) or any 

combustible  material  other  than  wood 

flooring,  the  fireplace  must  be  installed 

upon  a  metal  or  wood  panel  extending 

the full width and depth of fireplace.

3.  Set fireplace directly in front of opening 

and  slide  unit  back  until  nailing  flanges 

touch side framing.

4.  Check  level  of  fireplace  and  shim  with 

sheet metal if necessary.

5.  Before  securing  fireplace  to  prepared 

framing,  provided  ember  protector  must 

be placed between hearth extension (not 

supplied) and under bottom front edge of 

fireplace to protect against glowing embers 

falling through. If fireplace is to be installed 

on a raised platform, a Z-type ember pro

-

tector (not supplied) must be fabricated to 

Fireplace inSTallaTion

Continued

fit  your  required  platform  height.  Ember 

protector should extend under fireplace a 

minimum of 1 

1

/

2

". Ember protector should 

be made of sheet metal (28 gauge mini

-

mum to prevent corrosion.

6.  Using screws or nails, secure fireplace to 

framing through flanges located on sides 

of fireplace (see Figure 2).

Figure 1 - Framing Dimensions

Figure 2 - Nailing Flanges

As Required by Design as Lon

g

as Ceiling Clearance Is Maintain

ed

53 

7

/

8

"

(136 cm) 

Min

.

44 

5

/

8

"

(113 cm)

Min

.

Platform Must be
Solid, Flat and
Fully Supported

22 

3

/

4

"

(58 cm

)

"Z" Type 

Ember Protector

(Not Supplied)

12 

3

/

8

" Dia.

(31.4 cm) Outer Pipe

2" (5.1 cm) Min. 
Clearance From Outer 
Pipes to Combustibles

1" (2.5 cm) Min.
To Combustibles

21 

5

/

16

"

(54 cm)

42 

5

/

8

"

(108 cm)

24"

(61 cm)

12"

(31 cm)

Nailing 

Flanges

Prepared 

Framing

Nails or 

Screws

3/4" 

Clearance is 

Not Required 

at Nailing 

Flanges

Содержание 368STM-1

Страница 1: ...free log can only be installed in an aftermarket completion of sale not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes A...

Страница 2: ...or local distributor IMPORTANT Check HUD re quirementsbeforeinstallingthis fireplace Model 368STM is specifically designed for use in manufactured mobile homes This fireplace includes a manual contro...

Страница 3: ...ill make installation easier 4 An outside air kit is available with this fireplace see Outside Air Kit on page 5 WARNING Donotinstallthis appliance in a bedroom 24 37 1 2 20 1 2 10 1 4 53 1 2 17 1 2 4...

Страница 4: ...the full width and depth of fireplace 3 Set fireplace directly in front of opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if...

Страница 5: ...means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 3 WARNING Hearthextension is to be installed only a...

Страница 6: ...tion air is accessed through mobile home floor using air kit modelAK 6 or a side wall using air kit model AK 6WI see Accessories on page 14 CAUTION Combustion air inlet ducts shall not terminate in a...

Страница 7: ...mble to firestop spacer An opening large enough to allow insertion of firestop thimble assembly will be required in the ceiling Attach firestop thimble assembly to ceiling ceiling joist using screws o...

Страница 8: ...mum of 36 above high est point where it passes through roof 16 3 8 Min 48 3 cm 30 Min 76 cm 2 Min 5 1 cm 2 Min 5 1 cm 2 Min 5 1 cm Opening A PITCH SLOPE OPENING A MAX FLASHING MODE NO Flat 0 17 6F 8 0...

Страница 9: ...4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2...

Страница 10: ...ions with slip sections Note Storm collar is required but can be installed after home is sited Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Th...

Страница 11: ...al distance of 10 feet see Figure 19 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10 Foot Rule Chimney Support Bracket Kit CSK 8DM If exposed portion of chimney is greater than fiv...

Страница 12: ...nt free appliance available through your local distributor Use only a 1 2 black iron pipe and appropriate fittings When installing a gas line a shutoff valve designed for installation outside the appl...

Страница 13: ...place When fireplace is in operation doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created see Figure 23 A fireplace equipped with glass doors operates much differen...

Страница 14: ...ll to close and push to open Always open both handles before starting a fire This provides adequate outside combus tion air Close both handles when not in use to prevent cold air from entering the roo...

Страница 15: ...144 96 12 30 AccessorIES Continued SQUARE CHASE TOP TERMINATION ETL 8DM Optional OUtside air kit for side wall installation AK 6WI Hearth extension he 36 Thimble extensions TXL 8DM 43 TX 8DM 26 Vent...

Страница 16: ...have further questions about installation operation or troubleshooting If so contact Style Crest Inc at 1 800 231 4822 or write to Style Crest Service P O Box 19110 Wichita KS 67204 When calling or wr...