06

WIRING

For Single Speed Pumps

If the pump comes with a power cord, no wiring is needed. 

If not, wire the pump as below:

230

115

How to wire 230V

• Make sure the switch is at the 230V side. 

• Ground wire connects to the ground terminal. 

• Hot wire connects to terminal 1 or 3; a neutral wire connects to terminal 3 or 1. Either hot wire or

neutral wire is compatible with terminal 1 or 3. 

• Turn on the power and run the pump.

How to wire 115V

• Make sure the switch is at the 115V side. 

• Ground wire connects to the ground terminal. 

• Hot wire connects to terminal 1 or 3, a neutral wire connects to terminal 3 or 1. Either hot wire or 

neutral wire is compatible with terminal 1 or 3. 

• Turn on the power and run the pump.

WARNING:

 

All electrical wiring must conform to local codes, regulations, and the NEC.

WARNING:

 

Turn off power to pump before working on electrical connections.

Содержание VVPS215BUS

Страница 1: ...USER MANUAL DUAL SPEED POOL PUMP ...

Страница 2: ...eview the contents of this manual before attempting to operate the equipment This manual should be located where it can be easily referenced by all users of themachine NEED HELP CONTACT US Have product questions Need technical support Please feel free to contact us CustomerService vevor com ...

Страница 3: ...4 Strainer body 5 Drain Plug 6 Diffuser O Ring 7 Diffuser 8 Impeller 9 Pump Casing O Ring 10 Pump Housing 11 Screw 12 Motor 13 Carrier 14 Shaft Seal ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY...

Страница 4: ...water to return to the pool Remove pressure test plugs and or plugs used in winterization of the pool spa from the suction outlets Fail to do so will result in an increased potential for suction entrapment Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Before working on any electrical equipment turn off the power supply to the equipment Do not permit children...

Страница 5: ... must be solid level rigid and vibration free WARNING This product should be installed and serviced by a qualified pool professional All electrical wiring must be in conformance with applicable local codes regulations and the National Electric Code NEC It is strongly advised to protect the electrical components from direct sunlight though this pump is designed for outdoor use If installed within a...

Страница 6: ...05 THP 1 5 2 0 L 13 58 345mm 14 17 360mm ...

Страница 7: ...e or neutral wire is compatible with terminal 1 or 3 Turn on the power and run the pump How to wire 115V Make sure the switch is at the 115V side Ground wire connects to the ground terminal Hot wire connects to terminal 1 or 3 a neutral wire connects to terminal 3 or 1 Either hot wire or neutral wire is compatible with terminal 1 or 3 Turn on the power and run the pump WARNING All electrical wirin...

Страница 8: ...r the motor s voltage phase and cycle and that the wire size is adequate for the HP kW rating and distance from the power source Warning All electrical wiring must be performed by a licensed electrician Warning All electrical wiring must conform to local codes and NEC regulations Warning Use copper conductors only Recommended Wire Size 0 50 No 14 No 14 No 14 No 12 No 14 No 10 No 14 No 10 No 14 No ...

Страница 9: ... pump reassemble the strainer lid and drain plugs Place pump in a shady and dry area Voltage from the power must be in the range from 90 to 110 of the motor nameplate rated voltage Otherwise the motor may overheat and result in overload tripping and reduced component life Install ground bond and wire motor in accordance with local or NEC requirements The motor should be grounded permanently by con...

Страница 10: ...e fully open and not blocked that the pool water level is at a proper level and that the skimmer weir is not hung up or stuck on the skimmer wall Block off to determine if the pump will develop a vacuum You should have 5 6 of vacuum at the strainer cover You may be able to check by removing the skimmer basket and holding your hand over the bottom port with the skimmer full and pump running If no s...

Страница 11: ... pool and unrestricted discharge return lines Correct suction condition or throttle return lines if practical NOISY PUMP Vibration due to improper mounting etc Put a rubber pad under metal mounting feet Foreign matter in the pump housing Loose stones debris hitting the impeller could be the cause remove any above Motor bearings noisy from normal wear rust overheating or concentration of chemicals ...