Vetus P8FA Скачать руководство пользователя страница 4

090507.01

Switch panel P8FA

Introduction

Each separate group on the Vetus switch panel type P8F is protected. 
Both push-in fuses and automatic fuses (thermal protectors or circuit 
breakers) can be used. A range of push-in fuses is supplied with the panel 
but automatic circuit breakers must be purchased separately. Each sepa-
rate group may be loaded to a maximum current of 15 A.!!! 

All 8 groups 

together should have a maximum load of 60 A

.

The LEDs (light emitting diodes) show which group is operating. The 
function labels are fitted with background lighting that can be switched 
off. The panel is suitable for both 12 Volt and 24 Volt electrical installa-
tions. 

Overloading

If a particular group is overloaded the equipment connected to that 
group will be switched off and the LED will go out. The particular group 
can be switched on again as follows. 
•  Set the switch to OFF (O)and solve the overloading problem. Take off 

the cap covering the fuses, see diagram 1, replace the push-in fuse 
with one of the same value or reset the automatic circuit breaker. Put 
the cover with the function labels back on and switch back to ON (|).

Installation

•  Fit the panel in such a position that the user can easily operate the 

switches and both the LEDs and the function labels can be seen clearly. 
The panel is splash proof, class IP64, provided that the cover is fitted 
properly over the fuse holder. 

•  Cut a hole in the instrument panel or a bulkhead using the template 

provided, see diagram 2. 

•  Take off the cover to the fuses and the front plate. Fit the switch panel 

using the 6 screws supplied. 

Use hand tools to prevent overtighten-

ing the screws!

 Refit the front plate.

  W

arning

Large currents through too thin wires or contact resistances caused 
by poor connections can result in wires or connections becoming 
very hot and could cause a fire.

•  Always connect 

both

 plus terminals (

BAT + INPUT 12/24V)

 to a battery 

and use insulated (5 mm) eye-bolt connectors. 

•  Use wire with a sufficiently large cross section, at least 4 mm

2

•  Fit a main fuse, 60 A, in the connection between the battery and the 

switch panel, see diagram 3.

•  Connect the minus terminal (

- GND

) directly to the battery or a central 

earth strip. Do not use the minus terminal on the switch panel to con-
nect the minus terminals of connected equipment. Use an insulated 
(6.3 mm) flat push on cable connector and wire with cross section at 
least 0.5 mm

2

.

Connect equipment (lights, pumps etc.) to be operated through the 
switch panel using connecting wire with sufficiently large cross section, at 
least 2.5 mm

2

, and insulated (4 mm) fork terminal connectors or pin plugs. 

Technical details

Power supply 

:  10 V – 32 V

Max. current per group 

:  15 A

Current used by ‘ON’ LEDs per group 

:  11 mA at 12 V

 

  25 mA at 24 V

Current used by background lighting  :  11 mA at 12 V
 

  12 mA at 24 V

Protection class of front 

:  IP64

Ambient temperature 

:  -20°C to +50°C

Size of panel 

:  99 x 161 mm

Required build in depth 

:  45 mm

Weight 

:  325 g

  ENGLISH

Содержание P8FA

Страница 1: ... installation Instrucciones de instalación Istruzioni per l installazione NEDERLANDS ENGLISH DEUTSCH FRANÇAIS ESPAÑOL ITALIANO Copyright 2019 Vetus b v Schiedam Holland vetusb v FOKKERSTRAAT 571 3125 BD SCHIEDAM HOLLAND TEL 31 0 0 88 4884700 sales vetus nl www vetus com Printed in the Netherlands 090507 01 2019 11 161 6 5 16 99 3 7 8 44 5 1 3 4 25 6 1 80 3 1 8 142 5 9 16 ø6 87 3 7 16 149 5 7 8 ...

Страница 2: ...090507 01 Switch panel P8FA MAX 15 A 12 24V 4 mm2 12 AWG 10 mm2 6 AWG 0 5 mm2 20 AWG MAX 60 A 2 5 mm2 14 AWG 1 2 3 ...

Страница 3: ...is aangebracht Maak met behulp van de meegeleverde mal een gat in het instrument paneel of in een schot Zie tekening 2 Neem de zekeringenkap en de frontplaat weg Monteer het schakelpa neel met de 6 meegeleverde schroeven Gebruik handgereedschap om overmatig aandraaien van de schroeven te voorkomen Plaats de frontplaat weer terug Waarschuwing Grote stromen door te dunne draden of overgangsweerstand...

Страница 4: ...the fuse holder Cut a hole in the instrument panel or a bulkhead using the template provided see diagram 2 Take off the cover to the fuses and the front plate Fit the switch panel using the 6 screws supplied Use hand tools to prevent overtighten ing the screws Refit the front plate Warning Large currents through too thin wires or contact resistances caused by poor connections can result in wires o...

Страница 5: ...ber dem Teil mit den Sicherungen angebracht ist Mit der mitgelieferten Schablone ein Loch im Armaturenbrett oder in einem Schott anbringen Siehe Abbildung 2 Die Sicherungskappe und die Frontplatte entfernen Den Schaltkasten mit den 6 mitgelieferten Schrauben befestigen Handwerkzeug benut zen um ein übermäßiges Andrehen der Schrauben zu verhindern Die Frontplatte wieder anbringen Achtung Große Strö...

Страница 6: ... boîtier à fusibles soit en place À l aide du gabarit fourni faire un trou dans le panneau d instruments ou une cloison Voir le croquis 2 Retirez le capot des fusibles ainsi que le panneau frontal Fixez le ta bleau de commande à l aide des vis fournies Utilisez des outils ma nuels pour ne pas trop serrer les vis Remettre en place le panneau frontal Avertissement Des courants élevés passant dans de...

Страница 7: ...nel de instrumentos o tabique usando la plantilla proporcionada vea la imagen 2 Retire la tapa de los fusibles y la placa frontal Coloque el panel de distribución mediante los 6 tornillos proporcionados Use herramien tas manuales para evitar apretar demasiado los tornillos Vuelva a colocar la placa frontal Advertencia Corrientes potentes por cables demasiado finos o resistencias de los contactos d...

Страница 8: ...i sia montato Con l aiuto della sagoma in dotazione praticate un foro nel panello degli strumenti o in un tramezzo Vedi disegno 2 Togliere il coperchio del portafusibili ed il pannello frontale Montare il quadro dei comandi mediante le 6 viti in dotazione Utilizzate attrez zi manuali per evitare un eccessivo serraggio delle viti Rimontare il pannello frontale Avvertimento Correnti intense attraver...

Отзывы: