10
040104.08
vetus®
Rigid fuel tanks 42 - 390 litres
5 Technical Data
Type : FTANK42 FTANK61 FTANK88 FTANK110 FTANK137 FTANK170 FTANK215 FTANK335 FTANK390
Capacity :
42
61
88
110
137
170
215
335
390 litres *)
9.2
13.4
19.4
24.2
30.1
37.4
47.3
73.7
85.8 Imp. Gallon *)
11.1
16.1
23.2
29
36.2
44.9
56.8
88.5
103 US Gallon *)
Weight
:
3.0 4.0 6.7 7.5 9.25 11.4 13.6 25.8 26.6
kg
*)
6.6 8.8
14.8
16.5 20.4
25.1 30 56.9 58.6
lbs
*)
Max. pressure:
30 kPa (0.3 bar, 4.4 psi)
Material :
Polyethene, colour : natural
*) The values stated in the Table are nominal values for capacity and weight. Slight deviation is possible.
3 Preparing for winter
It is advisable to fill the fuel tank with fuel completely during the
winter period in order to prevent condensation. Water droplets
in fuel are the ideal transporters of dirt and rust through narrow
pipes. A full fuel tank prevents the growth of bacteria in the tank.
4 Maintenance
Regularly check the air relief nipple and clean the sieve in the nip-
ple if necessary.
Every year, check the hoses and hose connections for possible
leakage and fit new hoses and/or hose clamps as necessary. Also
check the tank for damage caused by chaffing. Replace a dam-
aged tank immediately.