44
6 Maintenance
Checking and cleaning the raw water strainer
Daily, before starting.
7 Checking the raw water strainer
• Check daily whether there is any dirt in the
raw water strainer.
8 Cleaning the strainer
• Close the seacock before removing the lid
of the water strainer.
• Clean the raw water strainer as often as is
necessary, depending on the pollution of
the waterways, but at least once every 6
months. A clogged raw water strainer will
result in excessive temperatures or over-
heating of the engine coolant.
• Check the sealing between the lid and
housing after cleaning and re-assembling
the strainer. An improperly sealed lid will re-
sult in air sucked in by the sea water pump
which again will result in overheating of the
engine.
Содержание D-LINE VD4.120
Страница 1: ...Operation manual D LINE Marine Diesel Engines 360602 01 VD6 210 VD4 120 VD4 140 VD6 170 VD6 210 ...
Страница 2: ...ii ...
Страница 126: ...ZF63 572 22 1 2 726 28 9 16 197 7 3 4 245 9 5 8 127 5 106 4 3 16 VD6 170 VD6 210 1 10 124 13 Overall dimensions ...
Страница 132: ...130 ...