background image

Table of Contents

 

Rev. 5/8/2019 

ZLTT MANUAL 

Table of Contents

 

Copyright 2019 Vestil Manufacturing Co. 

Page 14 of 15 

 

4) Tabletop tilts very slowly 

o) Pinched hose. 

 

 

p) Velocity fuse locking. 

 

 

q) Incorrect counterbalance valve 

setting. 

o) Examine all hoses for kinks. 

Straighten kinked hose(s) to restore oil 

flow. 

p) Counterbalance setting is incorrect. 

Contact Vestil for assistance. 

q) Decrease counterbalance setting by 

turning socket head screw 

counterclockwise. 

5) Tabletop does not tilt 

r) Velocity fuse locking. 

s) Control transformer fuse blown. 

 

t) No supply voltage. 

 

 

u) Bad connection in control circuit. 

 

v) Something physically blocking the 

tabletop. 

w) Solenoid valve malfunctioning  

 

 

 

x) Solenoid valve or suction hose screen 

plugged. 

r) See solution P above. 

s) Test with multi-meter. Replace if 

necessary. 

t) Make sure power cord is plugged in. 

Also check fuses, breakers, and 

overloads to determine cause. 

u) Test all parts of circuit with multi-

meter. 

v) Walk around the table and look for 

items, material, etc. interfering with table 

movement.  

w) Check solenoid with multi-meter on 

diode-check function (measuring Ohms 

does not accurately test coil). 

x) Remove, inspect, and clean the valve. 

   

 

 

Labeling diagram 

   The unit should be labeled as shown in the diagram. However, label content and location are subject to change 

so your product might not be labeled exactly as shown. Replace all labels that are damaged, missing, or not easily 

readable (e.g. faded). Order  replacement labels by  contacting  the 

Parts Department

  online at 

http://www.vestilmfg.com/parts_info.htm

. Alternatively, you may request replacement parts and/or service by calling 

(260) 665-7586 and asking the operator to connect you to the Parts Department.

 

 

 

A  B 

A: Label 824 (both side walls and load-retaining  

wall of tabletop) 

 

 

B: Label 207 (both side walls) 

 

 

 

C: Label 221 (on toeguard junction box) 

 

 

D: Label 208 (both sides) 

 

 

E: Label 287 

 

 

F: Label 204 (both sides) 

 

 

Содержание ZLTT Series

Страница 1: ...ur Technical Service and Parts Department at 260 665 7586 The department can also be contacted online at http www vestilmfg com parts_info htm Table of Contents Specifications 2 Signal Words 2 Hazards...

Страница 2: ...1 6cm 44 111 8cm 48 121 9cm 83 3 4 212 7cm 69 1 4 175 9cm 4 000 lb 1 818 2 kg 2630 lb 1195 5 kg ZLTT 5272 2 48 71 1 2 181 6cm 52 132 1cm 48 121 9cm 83 3 4 212 7cm 77 1 4 196 2cm 2 000 lb 909 1 kg 2756...

Страница 3: ...he machine to support people This table is designed only for material handling Always watch the tabletop carefully as well as the load container while raising and lowering it This crane is designed fo...

Страница 4: ...10 102 Weldment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 4452 2 36 2 1 2 x10 ZLTT 4452 4 36 3 x10 2 21 15 112 002 Pin cylin...

Страница 5: ...0 102 Weldment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 5252 2 48 2 1 2 x10 ZLTT 5252 4 36 3 x 10 2 21 15 112 002 Pin cylin...

Страница 6: ...ment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 4472 2 48 2 1 2 x10 ZLTT 4472 4 48 3 x 10 2 21 15 112 002 Pin cylinder bracke...

Страница 7: ...ment leg assembly left 1 20 64135 Pin roll 3 16 x1 1 4 4 7 99 021 906 001 99 021 901 001 Cylinder hydraulic ram style ZLTT 5272 2 48 2 1 2 x10 ZLTT 5272 4 48 3 x 10 2 21 15 112 002 Pin cylinder bracke...

Страница 8: ...0VAC Single Phase Electric Circuit Diagram 04124019 Rev D NOTE Overcurrent short circuit protection and disconnect must be provided by the end user Control relay base layout top view Control relay bas...

Страница 9: ...he necessary length of the anchor bolts should be determined by the building engineer Drill 1 2 holes into the concrete at the location of each bracket hole to the necessary depth for your anchor bolt...

Страница 10: ...opens a path for fluid to flow back to the reservoir if fluid pressure exceeds 3 000psi The relief valve is a safety feature designed to prevent damage to the hydraulic system that would otherwise be...

Страница 11: ...ut pressing either of the necessary control buttons then the corresponding lowering cartridge valve needs to be cleaned Remove inspect and clean the lowering cartridge valve If the tabletop un tilts o...

Страница 12: ...levated table Describe the motion of the table as it rises as well as how it sounds Tilt the table Take more photographs and again describe the motion and sounds heard as the power unit operates Un ti...

Страница 13: ...oil of viscosity grade 150 SUS at 100 F ISO 32 at 40 C such as AW 32 or HO 150 or a non synthetic transmission fluid Synthetic transmission fluid can be used but only after slushing the hydraulic sys...

Страница 14: ...breakers and overloads to determine cause u Test all parts of circuit with multi meter v Walk around the table and look for items material etc interfering with table movement w Check solenoid with mu...

Страница 15: ...aulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How...