8. Failure Analysis &Trouble Shooting
Symptoms
Causes
Solutions
Power on, but the power
indicator is not on and the
appliance does not heat up.
1. The plug is not in place.
2. The micro switch is in bad
contact. It is disconnected.
1. Plug in again.
2. Regulate
the
limit
distance of the switch.
The heating indicator is on,
but the oil temperature does
not rise.
1. Connection
of
heating
element is loose or falls
off.
2. The heating element is
burnt out.
1. Fasten the connecting
wires and screws on
both end.
2. Replace
the
heating
element.
The power indicator is on,
after having the temperature
set, the temperature does not
rise.
1. The thermostat is burnt
out.
1. Replace the thermostat.
Oil temperature control is
normal, but the indicator is
not on.
1. The indicator is burnt out.
1. Replace the indicator.
After circulating heating up to
high temperature, the heating
element does not heat up
again.
1. The
thermal
breaker
activates.
1. Manual reset
“overheat
protection reset button
”.
Oil temperature keeps rising
and out of control.
1. The thermal breaker is
malfunctioning.
1. Replace
the
thermal
breaker.
Aforementioned troubles are just for reference. If any failure occurs,
please stop using and inform the professional technicians to check and
repair.