■Operation

 

 

Selecting nozzles   

Flare Nozzle and Tube-fitting Nozzle are available as option. 

Depending on installation place and object to be neutralized, 

you may choose an appropriae nozzle. 

Note: Please be sure to attach the nozzle in a correct way. 

 

High Voltage Warning and Automatic Shut-off   

When the incorporated high voltage  transformer detects 

electrical overload, corona discharge stops and the LED light 

on the top turns red.   

Please switch off the unit as soon as the alarm has been 

activated.   

If the electrode needle is contaminated with dust or other substances, clean it and confirm 

whether or not the unit can be turned on properly.   

If the LED light still glows red after cleaning the needle, please contact the local distributor for 

repairing or maintenance service. Do not attempt 

to repair the unit on your own. 

 

 

External Output of Warnings     

The N-3 can be connected to warning device like 

patrol lamp through its external pin. 

 

■Maintenance

 

 

CAUTIONS

 

IN MAINTENANCE AND CHECKS

 

  DO NOT DISASSEMBLE 

Do not perform any maintenance on the N-3 except for 

maintenance and replacement of the electrode. 

  REMEMBER 

Before cleaning the electrode, shut off power and air supply at 

the source and disconnect the air hose. 

  PROHIBITED 

Do not wipe the ionizer with detergent or solvent. Substances 

of the sort can cause cracking and result in electric shock or 

breakdown. 

  DO NOT WET 

Do not wet the N-3. Exposure to moisture can result in electric 

shock or breakdown. 

 

Dirt and wear in the electrode area can deteriorate the performance of this ionizer. Clean the 

electrode  every 300 hours of use. If the electrode  is not kept in an optimum condition, the 

performance will drop and product life might shorten as well. If the unit is used for a long period of 

time, the tip of its electrode may wear out and consequently static erasing efficiency will decrease. 

In such case, replace the electrode with a new one. It is recommended that the electrode be 

replaced every 1,200 hours of operation. Keep the unit in good working condition by measuring 

its ion balance and ion output regularly as a means for checking for a drop in capacity.   

Содержание STAT CLEAN N-3

Страница 1: ... instruction manual before use Keep it for your ready reference Table of Contents For Your Safety P 2 Features P 3 Specifications P 4 Performance P 5 External View P 5 Installation P 6 Operation P 7 Maintenance P 9 Troubleshooting P 11 Storage P 11 Abbeon Cal Inc 1363 Donlon Street Unit 1 Ventura CA 93003 8387 800 922 0977 www Abbeon com E mail abbeoncal abbeon com ...

Страница 2: ... 3 in environments that require explosion proofing TheN 3 is not of explosion proof construction therefore explosion or fire may occur WARNING Do not use the N 3 in flammable atmospheres The corona discharge can act as an ignition source and cause an explosion or fire PROHIBITED Do not use the N 3 in environments subjected to sharp temperature fluctuations or dewing This kind of environment can le...

Страница 3: ... it easy to see its operating status Features an LED light on the top which glows green while in normal operation and turns red after the generation of the ion decreases due to abnormal operating conditions When an abnormality of High Voltage output is detected the N 3 stops the output forcibly To restart from the stopping please turn off a power supply once and then turn on the power supply again...

Страница 4: ... 85 RH No dewing Decay time 1000V to 100V within 0 7sec 0 3MPa 150mm Ion balance Within 10V 0 3 MPa 150 mm Safety feature It stops when the HV power supply is abnormal Lock and Red LED Lighting Weight 104g Dimensions L95 W50 H47mm Material Casing ABS Nozzle ABS Electrode Needle Tungsten Degrees of protection IP20 IEC 60529 Overvoltage category II IEC 60664 1 Pollution degree 2 IEC 60664 1 Accessor...

Страница 5: ... 1000 to 0V 1000 to 0V The data shown above was measured with initially charged voltage of 1000V Air Pressure 0 3 MPa Temperature 25 0 C Humidity 50 0 R H CPM 20pF 150mm square Tube fitting Nozzle with a tube O D 6mm length 300mm External View ...

Страница 6: ...n may cause a breakdown Please make sure all the electrodes are connected according to their polarity before turning on the unit Check before use Before use check the unit tube and power harness in order to make sure there is no damage loose screws disconnected hosing loose connectors etc CAUTIONS FOR INSTALLATION REMEMBER Use an air hose appropriate for required pressure resistance Air hoses of i...

Страница 7: ... from any heat source PROHIBITED Do not use the N 3 if it has a defect Instructions for wiring Power Source 1 Connect the DC24V power to No 6 connection pin of the power harness and the grounding wire to the No 5 connection pin Please refer to the illustration at the right Connection pins No 2 and No 1 are connected in parallel with No 6 and No 5 respectively For the multiple connection of this un...

Страница 8: ...t at either side Please refer to the illustration 1 Connect an air hose φ6 0 x φ4 0 mm to the air inlet of N 3 2 Air pressure should be adjusted within the range between 0 1 and 0 6 MPa with an appropriate air regulator Ion balance fluctuates according to air pressure and volume in use Lower air pressure is recommended for semiconductor material sensitive to static electricity 3 Supply dry clean a...

Страница 9: ... IN MAINTENANCE AND CHECKS DO NOT DISASSEMBLE Do not perform any maintenance on the N 3 except for maintenance and replacement of the electrode REMEMBER Before cleaning the electrode shut off power and air supply at the source and disconnect the air hose PROHIBITED Do not wipe the ionizer with detergent or solvent Substances of the sort can cause cracking and result in electric shock or breakdown ...

Страница 10: ...Nozzle firmly If it is fastened too tightly it may be damaged or break but if it is fastened too lightly the nozzle may come off while in use How to Replace the Electrode Needle Needle must be replaced with the Electrode needle Replacement Driver Separate be sold Make sure to shut off power supply before the replacement Replacement Order Remove the Nozzle Release the screw with the attached Electr...

Страница 11: ...ER OFF Unplug power cable if the N 3 has a defect DO NOT DISASSEMBLE Do not disassemble the N 3 Using broken N 3 may cause product damage or personal accident Therefore request servicing promptly if such trouble occurs For servicing contact your local distributor Storage CAUTIONS IN STORAGE PROHIBITED Do not store the N 3 in the following places Adverse environments can cause product breakdown Whe...

Страница 12: ...erly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract arising out of the use of or the inability to use the pro...

Отзывы:

Похожие инструкции для STAT CLEAN N-3