7
■
Installation
Caution
Caution
The High Voltage Power Supply GP-1 must always be grounded. If the
product is not sufficiently grounded, it will not perform up to its full
capabilities.
Also, when touching the casing of the GP-1 or the body of the HPG-1, you
may receive a light electric shock.
REMEMBER
Do not power on High Voltage Power Supply GP-1 until all of the steps are
completed.
Wiring the High Voltage Shielded Cable
Caution
REMEMBER
High voltage shielded cables have a product lifetime (approx. 10,000 hours).
The cables require constant maintenance.
Consider carrying out inspections and replacements when laying the high
voltage cables. Also, whenever the high voltage cable is damaged, it must be
repaired or replaced.
REMEMBER
Do not bend the high voltage shield cable at a sharp or right angle. The minimum
bend radius of the cable is about 60 mm (inside dimension). Also, do not use the
cable in the state it scrapes against a sharp metal plate, machine frame edge, etc.
Such a state may quickly degrade insulation of the high voltage shield cable to
cause an accident.
REMEMBER
Be sure to connect the ground wire of the high voltage shield cable terminal on
the power supply side, to the ground terminal of high voltage power supply GP-1.
Otherwise, you may get an electric shock from the gun body or the high voltage
cable.
REMEMBER
If the high voltage cable is broken during power distribution, sparks are emitted
from it. In that case, immediately stop using it and ask repair. Meanwhile, if a short
circuit occurs between the core wire and the shield coating (grounding object) ,
the safety circuit (anomaly detection circuit) of the GP-1 is triggered to
automatically stop the power supply.
REMEMBER
The high voltage shielded cable is a special electric wire that is designed to
feed high voltage. Never damage it. Handle it with care, to prevent breakage
by acute bending, deformation by pulling, etc. Moreover, be careful to avoid
getting it wet, having metal powder (machining dust) attached, etc.
REMEMBER
The high voltage cable portion connected to the head nozzle of the gun is not
shielded. Therefore, do not pull the portion or use it for hanging the gun.
PROHIBITED
Never disassemble the GP-1 or the HPG-1. Never make a modification such as
shortening of the high voltage cable.
PROHIBITED
When using the high voltage cable, do not intersect or contact it with a signal
wire or an electric power wire of a large volume motor.
Due to noise transmission,
a malfunction or a failure may occur on the product or a device with low noise
tolerance.
Содержание HPG-1
Страница 5: ...5 External Dimension High Power Ionizing Gun HPG 1 ...
Страница 11: ...11 memo ...