Vessel HPG-1 Скачать руководство пользователя страница 3

 Product Overview 

Product Overview 

High Power Gun HPG-1 is a static eliminator which is designed to eliminate static charges and dusts 

from a charged object by ionizing compressed air, which is supplied from a compressor, by the 

discharge electrode equipped inside the gun, and blowing it to the object. 

 

The HPG-1 should be used together with its dedicated high voltage power supply GP-1 which is also 

available from us. High voltage of 3.5 kVAC is used for this product HPG-1. Therefore, it is necessary 

to adjust the output voltage of High Voltage Power Supply GP-1 to be 3.5 kV (For details, refer to the 

GP-1 instruction manual). 

 

The dedicated AC adapter AD24-GP or AD24-GPE for the High Voltage Power Supply GP-1 supports 

a wide range of input voltage (single phase 100 to 240 VAC, and 50 to 60 Hz). If using DC power 

supply for machinery, equipment, etc., connect a 24VDC ± 10% 1A power supply. In this case, 

connect the 0V side to ground. 

 

Product Features 

 

Titanium discharge needle (discharge electrode) 

For the discharge electrode of the product, titanium, which has resistance against wear damage, is 

used so that stable performance can be kept for a long time. By using clean dry air, static 

eliminating performance improves, and the frequency of cleaning the electrode can be reduced. 

 

 

Silicone-shield high-voltage cable 

* A silicone cable with great durability is used as the high voltage cable of the product. This cable   

  is also shielded, so it reduces the negative influences by the high voltage electric field 

  (in consideration of EMC) and simplifies the wiring.   

* Urethane, cleaning-easy material, is used for cable exterior. 

* The cable length can be changed to up to 5m as an option. 

* Non-shielded type is also available as option. Please contact us for more detail. 

 

 

Strong die-cast aluminum gun body 

The gun body is made of light and durable aluminum die-cast. 

 

● 

Two-way type air gun with a large lever 

An air tube can be connected to the top or the bottom of the product. Although a one-touch joint 

for 8 mm (outside diameter) air tube is attached at the time of shipping, it can be replaced with a 

coupler joint (standard accessory). Also, a large, easy-to-pull lever is equipped for better 

workability. 

 

 

Ion balance adjustment circuit 

High Voltage Power Supply  GP-1 for this product is equipped with a circuit for ion balance 

adjustment. According to your environment and/or conditions, the ion balance can be easily 

adjusted through external operation of the adjustment portion. High Voltage Power Supply GP-1 

has two output terminals and can connect up to two guns. However, in that case, it is not possible 

to adjust the ion balance of each of them. Therefore, when the ion balance is an important factor, 

it is recommended to use just a single gun so that you can adjust the ion balance.

 

 

 

Safety/Anomaly Detection Circuit 

High Voltage Power Supply GP-1 is equipped with a safety circuit which automatically shuts off the 

output when a high voltage short circuit is detected. Also, it has an alarm output terminal. 

 

Содержание HPG-1

Страница 1: ... charges 〇 It is intended to be used to address various production problems caused by electrostatic charges CONTENTS Before Using the Product P 2 Product Overview P 3 Main Specifications P 4 External Dimension P 5 Installation P 6 Operation Procedure P 8 Maintenance and Anomaly Handling P 9 Troubleshooting P 10 Storage P 10 ...

Страница 2: ...lorine and so on There is a risk of electric shock and or product breakdown PROHIBITED Don t use this product in a place where a considerable shock and or vibration are given and or where a sharp temperature fluctuation or dew condensation occurs PROHIBITED Be sure to use this product within a range of conditions of use in the section of Specifications including the electric rating Otherwise there...

Страница 3: ...roduct This cable is also shielded so it reduces the negative influences by the high voltage electric field in consideration of EMC and simplifies the wiring Urethane cleaning easy material is used for cable exterior The cable length can be changed to up to 5m as an option Non shielded type is also available as option Please contact us for more detail Strong die cast aluminum gun body The gun body...

Страница 4: ...time Approx 0 5 sec Input air pressure 0 3 MPa Distance 150 mm Ion balance Adjustable on the GP 1 4kV A charged plate monitor or equivalent is required Installation place Indoors Protection circuit High Voltage Power Supply GP 1 is equipped with a high voltage anomaly detection function and automatic stop circuit High voltage cable Standard accessory 3m cable 2 silicone shielded cable Termination ...

Страница 5: ...5 External Dimension High Power Ionizing Gun HPG 1 ...

Страница 6: ...upply GP 1 close to the equipment on which the air gun HPG 1 is installed Firmly secure it to a strong frame wall floor etc using four M5 screws through the holes in the bottom of the mounting base When installing the GP 1 on a vertical surface make sure the high voltage output connector is on the bottom The GP 1 weighs approximately 4 5 kg Please handle with great care to avoid serious injury due...

Страница 7: ...power supply side to the ground terminal of high voltage power supply GP 1 Otherwise you may get an electric shock from the gun body or the high voltage cable REMEMBER If the high voltage cable is broken during power distribution sparks are emitted from it In that case immediately stop using it and ask repair Meanwhile if a short circuit occurs between the core wire and the shield coating groundin...

Страница 8: ...ltage cable at an arbitrary place It is recommended to attach it at the place where it is well remarked by the operator Connecting the Air Tube 1 Connect an air tube outside diameter of 8 mm and inside diameter of 5 mm to the one touch joint which is located on the bottom of the grip portion of the gun body The one touch joint can be replaced with the coupler joint standard accessory When supplyin...

Страница 9: ...op the supply of power to the body part and contact the dealer from which the product was purchased Other Anomalies If any of the following phenomena occur immediately stop the supply of power to the body part and contact the dealer from which the product was purchased Sparks are being emitted due to damage to the antistatic electrode or the high voltage cable The high voltage connector portion or...

Страница 10: ...s to be connected to the GP 1 or replacing with the optional short high voltage cable The electrode and insulation of the gun body are extremely dirty Clean or replace the electrode etc Failure of the gun body or the high voltage cable short circuit etc If the GP 1 stops detecting anomaly when the high voltage cable is disconnected replace the electrode and the high voltage cable Breakdown of the ...

Страница 11: ...11 memo ...

Страница 12: ...s neglect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or cont...

Отзывы: