29
Maintenance
Accessories
Electrode
Needle Unit
Filter
:
F-6H
SDJ-08F
Static Erasing Capacity Check
Measure ion balance and charge voltage dampening time using a charge plate monitor.
Reference: IEC61340-5-1-2, ANSI/EOS3.1
Adjustment
Because ions are generated with AC output, the SDJ-08 does not have an adjustment feature of
ion balancing. If ion balance is not good, contact Vessel.
Troubleshooting
Using F-6R when in anything but proper working condition can cause product damage or personal
accident. Therefore, promptly request servicing if trouble occurs. For servicing, contact the place of
purchase.
CAUTION
TROUBLESHOOTING
PROHIBITED
Do not use F-6R in the following situations. It may result in fire or
electric shock.
* When F-6R has been damaged because of dropping or shock
* When air is not blowing though the power switch of the eraser is in
the ON position
* When the power cable is damaged or hot
* When the power supply adapter is loosely connected to the
electrical outlet
UNPLUG
POWER CABLE
If trouble occurs with F-6R, turn the power switch OFF and unplug
the power cable.
DO NOT
DISASSEMBLE
Do not disassemble F-6R.
In the following cases, contact the supplier for servicing.
Do not service F-6R yourself as this can be dangerous.
* If the power lamp does not light when the power switch is in the ON position
* If air is not blown when the fan speed varistor is turned
* If the casing moves during use and air blow turns on and off
* If the power cable is excessively hot
* If the power supply adapter is excessively hot
* If F-6 emits strange noises or vibrates during use
* If sparks are seen coming from electrode wire tips (In normal operation, sparks are not seen.)
Содержание F-6R