 Maintenance

 

Cleaning / replacement of the electrode needle unit (Louver and needles) 

After using long hours, dust adhered around the electrode wires. Dust adhesion can lower the 
performance of ionizing. Clean the electrode needles after every 100-hour operation.   
Before cleaning the front guard, shut OFF power and unplug the power supply transformer from 
the electrical outlet.   
The electrode needles and the stopper should be securely put back on the unit after cleaning. 
If the louver is not properly mounted, the unit cannot be turned on due to its safety mechanism. 

Please replace it with a new one if the electrode needles are broken, missing or loose. 

(Electrode needle unit F-6H is available for replacement.) 

 

  CAUTION

 

   

CLEANING 

A dirty louver could lower the static erasing performance or cause dust 
to fly around. Be sure to clean it as required by the operation 
environment. 

  WARNING 

 

PROHIBITED

 

If the electrode needle unit is broken or dropped out, stop the 
operation and replace it with a new one. It can lead to an electric shock 
or injury. 

 

Instructions for cleaning 

1. 

Pull off the plug of the AC-DC power transformer 
from the power socket or pull off the connector of 
the transformer from the unit. 

2. 

Remove the stopper from the unit by pressing the 
sides of the stopper.   

3. 

Rotate the needle unit counter-clockwise and 
remove it. 

4. 

Wipe the louver with a dry clean cloth. 
Be careful not to hurt your fingers or hands with the 
needles attached to the backside of the louver. 

5. 

Clean the electrode needles with a cotton swab. 
Stubborn stains may be removed with a cloth lightly 
dampened with alcohol. Be careful not to give too 
much pressure on the needles as they might be 
warped or bent. 
Beware of the needles not to hurt yourself. 

6. 

Return the electrode needle unit back on properly 
with its blades positioned as shown in the right-side 
diagram. 

 

7. 

Put back the stopper to the unit. Make sure to return it properly. Otherwise, the safety 
mechanism prevents the unit to be turned on. 

8. 

Connect the AC-DC power transformer. 

 

 

3

5

6

Содержание F-6R

Страница 1: ...al before use Keep it in a safe handy place for future reference Table of Contents For Your Safety P 2 Product Features P 3 Production Specifications P 4 External View P 5 Performance P 6 Installation P 6 Before Use P 8 Operation P 9 Maintenance P 10 Troubleshooting P 14 Storage P 15 Warranty P 16 ...

Страница 2: ...explosion proofing F 6R is not of explosion proof construction therefore explosion or fire may occur PROHIBITED Do not use F 6R in flammable atmospheres The corona discharge can act as an ignition source and cause an explosion or fire PROHIBITED Do not use F 6R in environments subjected to sharp temperature fluctuations or dewing This kind of environment can lead to breakdown DO NOT WET Do not use...

Страница 3: ... machinery DESIGNED FOR SAFETY To prevent electrical shock the circuit is cut off and the power turned off when the front guard is opened During operation the interior high brightness white LED lights up and the operating condition can be visually checked LED Lamp Function The red LED indicators on the top of the unit notify you in case of fan motor stoppage and abnormally high voltage High voltag...

Страница 4: ...ltage output shut down function overload detection Front cover safety device circuit cut off when open Protective function Over current protection fuse 1 0 A Reverse current connector protection diode 60 V 1 A Working temperature humidity 5 40 35 65 RH No dewing or freezing Storage temperature humidity 0 60 35 85 RH No dewing or freezing Distance from target area 150 600 mm Installation location N...

Страница 5: ...21 External View External View AD24 ITF6 ...

Страница 6: ... 6 8 4 9 9 9 4 4 4 5 4 5 5 5 6 8 3 7 4 6 5 1 7 4 5 2 6 4 5 5 5 6 7 9 100mm 9 8 2 4 1 6 8 5 2 6 2 6 8 9 2 9 3 1 1 8 3 0 3 6 6 2 4 0 4 9 4 1 4 3 5 7 50mm 3 5 3 0 1 5 0 9 2 5 2 1 6 3 2 6 2 7 4 0 3 1 3 5 5 9 3 5 4 1 3 5 4 2 4 9 0mm 9 8 2 1 3 5 0 2 4 2 6 0 4 3 0 3 3 0 3 3 2 3 7 1 9 3 8 4 4 4 5 4 2 5 4 50mm 8 5 4 0 3 0 3 8 4 2 4 4 4 6 4 5 5 1 4 7 4 7 5 2 1 2 4 8 5 5 0 7 4 7 6 1 100mm 0 5 55 5 44 8 2 2 1...

Страница 7: ...ons occurs Where there is heavy dust or smoke Where possibly wet by water oil chemicals etc Where strong electric or magnetic fields are generated 1 To be installed on desktop F 6RST E Do not place the unit on an unstable surface It may cause breakage if the unit falls 2 To be mounted to walls or structures F 6RST E The installation height should be determined with its effective ionizing area in m...

Страница 8: ...ans The length of M5 screws should be up to 6 mm from the surface of the unit Before Use CAUTIONS IN BEFORE USE REMEMBER Use only the included power supply adapter Use of other adapters may results in fire electric shock and static electricity removal trouble REMEMBER If noticing anything strange stop using F 6R immediately PROHIBITED Do not use F 6R other than static electricity removal PROHIBITE...

Страница 9: ...me the power is turned on Low power consumption FAN SPEED Fan speed can be changed by two steps HI LO ALARM LAMPS H V ALARM High voltage alarm lamp High voltage alarm lamp lights when electrode needle is grounded short circuited or high voltage booster unit does not output enough voltage If any foreign object attached to the electrode needles Please refer to the How to Clean the Electrode needle o...

Страница 10: ... electrode needle may sometimes require cleaning Dirt and wear in the electrode needle area can cause a decline static erasing capacity It is also recommended to measure ion balance and ion output as a means for checking for a drop in capacity Casing Cleaning To clean the casing wipe with a dry soft cloth Suck up dust from openings with a vacuum cleaner Do not use detergent or solvents such as alc...

Страница 11: ...needle unit is broken or dropped out stop the operation and replace it with a new one It can lead to an electric shock or injury Instructions for cleaning 1 Pull off the plug of the AC DC power transformer from the power socket or pull off the connector of the transformer from the unit 2 Remove the stopper from the unit by pressing the sides of the stopper 3 Rotate the needle unit counter clockwis...

Страница 12: ...28 27 ...

Страница 13: ...R has been damaged because of dropping or shock When air is not blowing though the power switch of the eraser is in the ON position When the power cable is damaged or hot When the power supply adapter is loosely connected to the electrical outlet UNPLUG POWER CABLE If trouble occurs with F 6R turn the power switch OFF and unplug the power cable DO NOT DISASSEMBLE Do not disassemble F 6R In the fol...

Страница 14: ...ions or shock Where temperature and humidity are outside specified ranges Where dewing occurs Where temperature fluctuates sharply Where there is the possibility of ignition or explosion of flammable solvents dust etc Where there is heavy dust or smoke Where possibly wet by water oil chemicals etc Where strong electric or magnetic fields are generated ...

Страница 15: ...31 Memo ...

Страница 16: ...t misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract ari...

Отзывы: