13
■
Product Specifications
Ionizer
Model
: No.CF600-E
Ion generation method
: High voltage AC (20KHz) corona discharge
Input voltage
: 24
V
DC
±
10
%
Consumption current
: 0.9A (max)
Dimensions
: H157
×
W640
×
D170
(
including stand
)
mm
Weight
: 4.6
㎏
Fan speed
: 2.5
㎥
/min
(
Max. fan speed
)
Noise emission
: 51.7 dB(A) Max. fan speed
(
Measured at 1m
)
Ozone generation
: 0.05ppm or less
Warning output
: High voltage alarm (Red LED),
Fan lock alarm
(
Red LED
)
Protective function
: Fan motor rotation monitoring function (Detecting rotation lock)
High-voltage output shut down function
(
overload detection
)
Power fuse 3.15A
Working ambient
temperature / humidity
:5
~
40
℃
/ 35
~
65%RH (No dewing or freezing)
Ambient storage
temperature / humidity
:0
~
60
℃
35
~
85%RH(No dewing or freezing)
Distance from target
area(recommended)
:150
~
900mm
(
Installation location: Non-hazardous indoor location
)
Static electricity
removal time
: Refer to the items in the performance chart.
Ion balance
: Within
±
10V (At 300mm ,at the time of shipment)
Air filter
: Rough filter
Material
: Casing ... SPCC,
Stand…SUS304
: Needle electrode... Inconel
Adapter No.AD24-IT19E
Rated input voltage
:100-240V AC (50/60Hz)
1.9A
Rated output voltage
:24V DC
1.9A
Working
temperature /humidity
:0~40
℃
10~85%RH
(
No dewing or freezing
)
*The measurement values were obtained under the VESSEL measurement environment, so error
could be induced depending on the operation environment.
■
Performance
Diagram of capacity area
Static electricity removal performance
Static electricity removal time: Time required to reduce charge electric potential from
±1000 V to ±100 V.
Relation between the distance to the charged object and the static electricity removal time
Area
A/F Max.
2.9m/s at
x, y = 0, 300mm
Time (Sec.) from
±
1000V to
±
100V
Equipment: Trek158
A/F Min.
2.5m/s at
x, y = 0, 300mm
Time (Sec.) from
±
1000V to
±
100V
Equipment: Trek158
<2Sec.
<4Sec.
<6Sec.
<8Sec.
<10Sec.
<2Sec.
<4Sec.
<6Sec.
<8Sec.
<10Sec.
<12Sec.