2)Load status check
After restoring the electrolyte level, check its density using an appropriate densitometer (see the figure).
When the battery is charged, you should detect a density of 30 to 32 Bé corresponding to a specific
weight of 1.26 to 1.28 at a temperature of no lower than 15° C.
A density reading of less than 20° Bé indicates that the battery is completely flat and it must therefore
be recharged.
After charging the battery, check each element electrolyte level and density. If the scooter is not used
for a given time (1 month or more) it will be necessary to periodically recharge the battery.
The battery runs down completely in the course of three months.
If it is necessary to refit the battery in the vehicle, be careful not to reverse the connections, remembering
that the earth wire (
black
) marked (-) must be connected to the
- negative
terminal while the other two
red
wires marked (+) must be connected to the terminal marked with the +
positive
sign.
Regular bench charging must be carried out with the specific battery charger, (single) or (multiple),
setting the battery charger selector to the type of battery to be recharged. Connections to the power
supply source must be implemented by connecting the corresponding poles (+ to+ and - to -).
4) Cleaning the battery
The battery should always be kept clean, especially on its top side, and the terminals should be coated
with Vaseline.
WARNING
- Before recharging the battery, remove the plugs of each cell. Keep the battery away from naked flames
or sparks when charging.
Remove the battery from the vehicle removing the negative clamp first.
CAUTION
NEVER USE FUSES WITH A CAPACITY HIGHER THAN THAT RECOMMENDED.
USING A FUSE OF UNSUITABLE RATING MAY SERIOUSLY DAMAGE THE VEHICLE OR EVEN
CAUSE A FIRE.
CAUTION
DRINKING WATER CONTAINS MINERALS THAT CAN BE EXTREMELY HARMFUL TO THE BAT-
TERY: USE DISTILLED WATER ONLY.
CAUTION
TO ENSURE MAXIMUM PERFORMANCE THE BATTERY MUST BE CHARGED BEFORE USE.
INADEQUATE CHARGING OF THE BATTERY WITH A LOW ELECTROLYTE LEVEL BEFORE IT
IS FIRST USED SHORTENS THE LIFE OF THE BATTERY.
Specific tooling
020333Y
Single battery charger
020334Y
Multiple battery charger
1)- Remove the short closed tube and the caps, then pour sulphuric acid into the cells using the type
specified for batteries, with a specific gravity of 1.26, corresponding to 30° Bé, at a minimum temperature
of 15°C until the upper level is reached.
2) - Leave to rest for at least 2 hours; then, restore the level with sulphuric acid.
Electrical system
ET4 50
ELE SYS - 54
Содержание ET4 50
Страница 1: ...WORKSHOP MANUAL 633367 ET4 50 ...
Страница 4: ......
Страница 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 16: ...INDEX OF TOPICS TOOLING TOOL ...
Страница 24: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 33: ...494929Y Exhaust fumes analyser 020331Y Digital multimeter ET4 50 Maintenance MAIN 33 ...
Страница 34: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Страница 40: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 56: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 58: ...INDEX OF TOPICS ENGINE ENG ...
Страница 120: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 130: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 136: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 144: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Страница 148: ...INDEX OF TOPICS TIME TIME ...
Страница 150: ...Crankcase CRANKCASE Code Action Duration 1 001133 Engine crankcase replace Crankshaft Time ET4 50 TIME 150 ...
Страница 184: ...BRAKE LEVER Code Action Duration 1 002002 Shoes Rear brake pads Replace ment Time ET4 50 TIME 184 ...