Vertiv
™
NetSure
™
-48 VDC Power System
System Application Guide
Spec. No: 582140001
Proprietary and Confidential © 2022 Vertiv Group Corp.
SAG582140001
Model No: 801
NLDB
, 801
NLEB
, 801
NL
-
B
Page 103
Revision T, September 28, 2022
dd
-
mon
-
yy
hh
:
mm
:
ss
/
CONTROLLER
ALARM LOG MENU
400
325
E
from
(Sheet 3 of 5)
356
384
425
GO TO FUNCTION MENU
GO BACK TO MENU TREE
BEGINNING
dd
-
mon
-
yy
hh
:
mm
:
ss
/
B#
-
SN#
dd
-
mon
-
yy
hh
:
mm
:
ss
/
PANEL
B#
-
P#A/B
dd
-
mon
-
yy hh
:
mm
:
ss
/
ROUTER
B#
dd
-
mon
-
yy
hh
:
mm
:
ss
/
RELAY
B#
-
P#
SYSTEM CONTROLLER
NO ALARMS
326
EMERGENCY STOP
INPUT ACTIVE
327
HI VOLTAGE SHUTDOWN
INPUT ACTIVE
328
SYSTEM VOLTAGE IS
VERY LOW
329
SYSTEM BATTERY IS ON
DISCHARGE
330
SYSTEM HIGH VOLTAGE
#1 ALARM
331
SYSTEM HIGH VOLTAGE
#2 ALARM
332
NO PCUs ARE
IN INVENTORY
333
NO DIST. PANELS ARE
IN INVENTORY
334
NO ROUTERS ARE
IN INVENTORY
335
NO RELAY BOARDS ARE
IN INVENTORY
336
HIGH TEMPERATURE #1
ALARM
337
MCA ALARM
LOG DETAIL MENU
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
HIGH TEMPERATURE #2
ALARM
338
LOW TEMPERATURE #1
ALARM
339
LOW TEMPERATURE #2
ALARM
340
TEMPERATURE SENSOR
NO SIGNAL
341
MAJOR MONITORING
ALARM(S)
342
MINOR MONITORING
ALARM(S)
343
Monitoring LED
Messages
344
MONITORING DOES NOT
RESPOND
345
CONTROLLER FAILURE
####
346
THE CONTROLLER IS
INITIALIZING
347
TOTAL LOAD CURRENT
ALARM
348
GROUP A LOAD CURRENT
ALARM
349
GROUP B LOAD CURRENT
ALARM
350
THE DISPLAY DOES NOT
RESPOND
351
SYSTEM OUTPUT SENSE
vv
.
vv
V
352
TOTAL LOAD CURRENT
aaaaa
A
353
PCU
B#
-
SN#
NO ALARMS
357
PCU
B#
-
SN#
EMERG. STOP
358
PCU
B#
-
SN#
H.V. SHUTDOWN
359
PCU
B#
-
SN#
AC LINE OFF
360
PCU
B#
-
SN#
AC LINE LOW
361
PCU
B#
-
SN#
AC LINE HIGH
362
PCU
B#
-
SN#
AC PHASE LOST
363
PCU
B#
-
SN#
POWER FACTOR
364
PCU
B#
-
SN#
DC/DC CONV.
365
PCU
B#
-
SN#
FUSE/BREAKER
366
PCU
B#
-
SN#
INHIBITED
367
PCU
B#
-
SN#
ON STANDBY
368
PCU ALARM
LOG DETAIL MENU
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
PCU
B#
-
SN#
THERMAL LIMIT
369
PCU
B#
-
SN#
THERMAL STOP
370
PCU
B#
-
SN#
HIGH AMBIENT
371
PCU
B#
-
SN#
LOAD SHARE
372
PCU
B#
-
SN#
1 FAN SPEED
373
PCU
B#
-
SN#
2+ FANS SPEED
374
PCU
B#
-
SN#
NO VOLT SENSE
375
PCU
B#
-
SN#
DUPLICATED
376
PCU
B#
-
SN#
NO RESPONSE
377
PCU
B#
-
SN#
TURNED ON
or
PCU
B#
-
SN#
TURNED OFF
378
PCU
B#
-
SN#
aaaaa
A
379
SYSTEM OUTPUT SENSE
vv
.
vv
V
380
TOTAL LOAD CURRENT
aaaaa
A
381
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
DIST. PANEL
B#
-
P#A/B
A/B CHANGED
392
DIST. PANEL
B#
-
P#A/B
PROCESSOR
393
DIST. PANEL
B#
-
P#A/B
IS
DUPLICATED
394
DIST. PANEL
B#
-
P#A/B
NO RESPONSE
395
SYSTEM OUTPUT SENSE
vv
.
vv
V
396
TOTAL LOAD CURRENT
aaaaa
A
397
DIST. PANEL
B#
-
P#A/B
NO ALARMS
385
DIST. PANEL
B#
-
P#A/B
DISCONNECTED
386
POSITION
B#
-
P#
A/B
IS OPEN
387
POSITION
B#
-
P#
A/B
NOT FOUND
or
POSITION NOT FOUND
PANEL
B#
-
P#A/B
388
POSITION
B#
-
P#
A/B
TYPE UNKNOWN
389
POSITION
B#
-
P#
A/B
OVER CURRENT
391
DIST. PANEL
B#
-
P#A/B
LVD FAILURE
391
DISTRIBUTION ALARM
LOG DETAIL MENU
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
ROUTER
B#
IS
DUPLICATED
417
ROUTER
B#
DOES NOT
RESPOND
418
ROUTER
B#
REMOTE
SENSE
vv
.
vv
V
419
ROUTER B# INTERNAL
SENSE
vv
.
vv
V
420
SYSTEM OUTPUT SENSE
vv
.
vv
V
421
TOTAL LOAD CURRENT
aaaaa
A
422
ROUTER
B#
NO ALARMS
412
413
ROUTER
B#
INTERNAL
SENSE OPEN
414
ROUTER
B#
PROCESSOR
FAILURE
415
ROUTER
B#
REPORTS AN
ILLEGAL NODE
416
ROUTER
B#
REMOTE
SENSE OPEN
ROUTER ALARM
LOG DETAIL MENU
SYSTEM OUTPUT SENSE
vv
.
vv
V
431
TOTAL LOAD CURRENT
aaaaa
A
432
RELAY BOARD
B#
-
P#
NO ALARMS
426
427
RELAY BOARD
B#
-
P#
PROCESSOR
428
RELAY BOARD
B#
-
P#
IS
DUPLICATED
429
RELAY BOARD
B#
-
P#
NO RESPONSE
430
RELAY
B#
-
P#
-
R#
IS
STUCK
RELAY ALARM
LOG DETAIL MENU
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
355
354
383
382
398
399
423
424
433
434
435
436
dd
-
mon
-
yy hh
:
mm
:
ss
/
I/O
B#
-
P#
411
GO TO ALARM LOG MENU
GO BACK TO MENU TREE
BEGINNING
I/O BOARD
B#
-
P#
NO RESPONSE
406
SYSTEM OUTPUT SENSE
vv
.
vv
V
407
TOTAL LOAD CURRENT
aaaaa
A
408
I/O BOARD
B#
-
P#
NO ALARMS
401
402
I/O BOARD
B#
-
P#
OVER CURRENT
403
I/O BOARD
B#
-
P#
PROCESSOR
404
I/O BOARD
B#
-
P#
IS DUPLICATED
405
I/O BOARD
B#
-
P#
BINARY
I#
I/O BOARD ALARM
LOG DETAIL MENU
409
410
ALTERNATE CURRENT
LIMIT ACTIVE
328A
BAY ###
REPLACE PCU
B#-P#
REPLACE PCU
B#-P#
W/
SN#
PCU REPLACEMENT
MENU
REPLACE ### PCUs?
AUTO IN ###
REPLACE ### PCUs
MANUALLY?
REPOPULATE ### SLOTS?
AUTO IN ### ?
MANUAL PCU
REPLACEMENT MENU
(NS702/801 only)
439
444
440
441
442
443