HD-98 Door Operator with OST
Door Setup
Printed in USA November, 2011
19
Close Adjustments Procedure
To avoid mechanical damage to the doors when increasing Open and Close High
Speed, do NOT make drastic changes.
1. E12 (Close High Speed) - Change E12 to a value that gives the desired close high speed. The
close high speed increases as the E12 value is increased.
2. E13 (Close Slowdown Deceleration Rate) - Change E13 to a value that gives the desired
deceleration rate from high speed to manual speed. The deceleration rate increases as the
E13 value is increased.
3. E14 (Manual Close Speed) - Change E14 to a level that causes the doors to stall when the close
deceleration is complete. This action determines if the close slowdown distance (E16) is set
correctly.
4. E18 (Close Travel-in Distance) - Change E18 to reduce travel-in distance to a level that does
not affect the close adjustment.
5. E16 (Close Slowdown Distance) - Change E16 to a value that allows the doors to stall 1” to 2”
from the closed position when E14 (Manual Close Speed) is adjusted to 1.
Note:
If the slowdown distance is set too low there will not be enough slowdown distance for the
doors to stop before the door close limit is reached. The close slowdown distance
increases as the E16 value is increased.
6. After the doors have stalled in the close direction, use the door open button to cycle the doors
and verify that the doors stall 1” to 2” from the jamb.
7. E14 (Manual Close Speed) - Change E14 to a value that allows the doors to move quickly but
smoothly into the door close limit. The manual close speed increases as the E14 value is
increased.
8. E18 (Travel-in Distance) - Change E18 to a value that allows the doors to travel smoothly into
the door close limit. The travel-in distance increases as the E18 value is increased.
Note:
Travel-in Distance - The point at which the door torque will be boosted on the fifth or sixth
attempt if the doors have been stalled while closing, and the watchdog timer has expired.
9. E15 (Close Acceleration Rate) - Change E15 to a value that allows the doors to move smoothly
but quickly from 3/4 manual speed to high speed. The close acceleration rate increases as the
E15 value is increased.