LIMITED WARRANTY

Vertex Water Products (“Manufacturer”) sell its products through independent retailer dealers (“Dealer”) who re-
sell to the end-user customer. In this limited warranty, “Vertex” refers to Vertex Water Products and not to the
Dealer.

WHO IS COVERED BY THIS WARRANTY

This limited warranty covers only the first purchaser of the Vertex

PureWaterCooler

from a Dealer for use by

that purchaser, and is not transferrable. “Consumer Use” means personal residential household use by a consumer
or consumers. “Commercial Use” means all other uses, including (but not limited to) use for commercial, income
producing purposes and/or when purchased by a business and/or when purchased for use in an office, business, or
industrial setting. “Purchaser” means the end-user customer, and not a Vertex re-seller Dealer.

PERIOD OF COVERAGE OF THIS WARRANTY

Manufacturer warrants the complete water cooler (“the unit”) against defects in material and workmanship, sub-
ject to the exclusions described below, for a period of ONE YEAR, beginning on the later of either (a) the date of
purchase or (b) the date of manufacture as identified by the Vertex unit’s serial number. Manufacturer additionally
warrants the compressor for a period of THREE YEARS from the above date. The purchaser must provide the
original sales receipt as proof of the date of purchase. If the purchaser is unable to produce the original sales re-
ceipt, the Warranty Period commencement date will be determined by Manufacturer, in its sole and absolute dis-
cretion, based upon the unit’s serial number. This warranty does not apply if the original serial number affixed by
Manufacturer is removed, defaced, altered, obscured, tampered with, or obliterated. If Manufacturer provides a
replacement part or parts, or repairs a part or parts, under this limited warranty, then the replacement part(s) or
repaired part(s) will be covered under this limited warranty for the time remaining under the original Warranty
Period applicable to the part(s) repaired or replaced.

The duration of

ALL OTHER WARRANTIES, INCLUDING ANY AND ALL IMPLIED WARRANTIES,

INCLUDING BUT NOT LIMITED TO MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE RESTRICTED TO THE TWO-YEAR LIMITED WARRANTY PERIOD.

Some states do

not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to purchaser.

WHAT IS COVERED BY THIS WARRANTY

This limited warranty covers defects in materials or workmanship, subject to the exclusions below and for the time
period stated above. Manufacturer promises to repair or to replace, at Manufacturer’s sole and absolute discretion,
any part of this water cooler that proves to be inoperative due to a defect in material or workmanship under normal
use.

WHAT IS NOT COVERED BY THIS WARRANTY

This limited warranty does not extend to and expressly excludes:
• conditions, losses, malfunctions, or damages not resulting from defects in material or workmanship;
• conditions, malfunctions, losses, or damages or the inability to operate the Vertex unit resulting from

conditions beyond Manufacturer’s control, including but not limited to failure of the unit or any of its
parts due to damage caused by: improper installation; accident; fire; flood; windstorm; acts of God;
rodent and/or insect infestation; vandalism; modification; alteration; combination with any other device
or machine; abuse and/or misuse of the unit; negligence by purchaser or third parties; any part of the
water system that has become fouled due to liming, dirt, unsatisfactory/unsanitary water conditions,
corrosion, or faulty plumbing; failure to install, maintain, assemble, mount or place the Vertex unit in
accordance with Manufacturer’s instructions and/or local, state, or national plumbing and electrical
codes; wear and tear expected to occur in the normal course of use, including but not limited to cosmetic
rust, scratches, dents or comparable and reasonably expected losses or damages; exposure to extreme
variations in ambient environmental conditions (including but not limited to changes in heat, humidity,
moisture, or exposure to sunlight).

• labor for installation or deinstallation of the unit or any of its parts; shipping of the unit or any of its parts

to Manufacturer for repair/replacement.

In addition to the above exclusions, this limited warranty does not apply if any of the following conditions
of operation are not met: System Pressure 35 - 100 psi, Temperature 40 - 100 degrees F, PH range 4 - 10,Max
TDS 1500 PPM Max., Turbidity <1.0NTU, Hardness <20gpg, R version: <3.5 gpg, F version, Iron
<0.1 mg/l, Manganese <0.1 mg/l, Hydrogen Sulfid e <0.00 mg/l.

Содержание PureWaterCooler PureChill PWC-9100

Страница 1: ...PureWaterCooler PureChill Water Dispenser OWNERS INSTALLATION OWNERS INSTALLATION OWNERS INSTALLATION OWNERS INSTALLATION MANUAL MANUAL MANUAL MANUAL Floorstanding Model PWC 9100 ...

Страница 2: ... 0 Filter Monitor 11 8 0 Filter Replacement 12 9 0 Trouble Shooting Guide 13 10 Specifications 14 11 Warranty 15 List of Figures Fig 1 Flow Schematic 2 Fig 2 PWC 9100 Assembly 3 Fig 3 Back View of Cooler 4 Fig 4a b Installation Precaution 5 6 Fig 5 Saddle Valve 7 Fig 6 Drain Connections 7 Fig 7 Quick Connect Fittings 8 Fig 9 Leak Detector 11 ...

Страница 3: ...s manual before operating the PureWater Cooler 2 0 Receiving the Cooler 2 1 Unpacking The PureChill model PWC 9100 is shipped completely assembled Remove the top of the box and pull the cabinet off of the base of the carton Save the box and packing materials for use in the event of a return 2 2 Inspection Inspect the cooler for obvious shipping damage Look at the exterior panels to see if they are...

Страница 4: ...ch is filled by the auxiliary reservoir The cold water drinking line is comprised of a sealed stainless steel coil submerged inside of this chilling chamber There is a separate hot water tank with an internal heater coil which is fed by gravity from the auxiliary reser voir The water level is controlled by a valve and float ball assembly The com pressor and expansion valve are inside the cabinet T...

Страница 5: ...p Cover Hot Tank Auxiliary Reservoir Chilling Chamber Key Lock Safety Button Cold Water Button Hot Water Button Control Panel To Dispense Cold Water Press Cold Water Button To Dispense Hot Water Press and release Key Lock Button then press Hot Water Button ...

Страница 6: ...nal 180 F and is controlled with a thermostat mounted on the outside of the hot tank The cold temperature can be adjusted between 36 F and 54 F by a using a screw driver on the slot from the top of the cooler with top cover removed Turn to the left to increase warmth and to the right to increase cold DO NOT TURN PAST THE STOPS Figure 3 Back View of Cooler 4 Hot Tank Inside Hot Tank Reset Drain Plu...

Страница 7: ... for the R version with re verse osmosis filter there must be access to a drain trap to which the reject water from the RO is delivered Normally this can be found in a bathroom or kitchen sink Flexible 1 4 inch plastic tubing may be used for the feed connec tion Normally this connection should be within 25 feet of the cooler Figure 4a Installation Precautions Keep at least a 4 in distance between ...

Страница 8: ...hen received the water connections on the back of the cooler have color coded tube sections with red shipping caps on them These tube sections must be removed before making water connections To remove the tube sec tions see Figure 7 The 1 4 plastic tubing should be used for making the Feed Water If hard copper tubing is used for the Feed Water and Drain connections the bulkhead fittings must be ch...

Страница 9: ...needle 1 2 turns to start water flow See Figure 5 4 5 Drain Connection The black drain line in the back Fig 5 must be hooked to the drain line ahead of the normal sink water trap See Figure 6 below Place the 2 part drain saddle on the drain pipe before the drain trap Allow proper space for the drilling operation Tighten the saddle bolts evenly on both sides Using the opening in the drain outlet sa...

Страница 10: ...aterCooler are of Quick Connect O ring seal design and manufacture Use the tubing and follow the instructions below to make the connections If you cut the tubing make sure it is a square cut fits squarely in the fitting and seals properly Figure 7 Quick Connect Fittings 8 ...

Страница 11: ...l come on automatically when plugged in The pump may make noise if the tank has not yet filled with water For F version allow 10 15 minutes to fill chamber For R version about 1 hour is required e Make sure Cold and Hot power switches at back of cooler are OFF before plugging the cooler into 110 volt wall socket See Figure f Plug in power cord To dispense cold water press Cold dispense button hold...

Страница 12: ...iner to collect the water about 3 1 2 gal Remove the white drain plug from the rear of the cooler This will drain the auxiliary tank chilling chamber hot tank and storage tank R only To remove the water in the stainless steel tubing in the storage tank disconnect the tubing from the outlet of the post filter if R from carbon filter if F and from bulkhead if no filtration located in the filter cabi...

Страница 13: ...from the replacement cartridge install with bevel side down 7 0 Filter Monitor Operation When water is dispensed the green indicator light will blink When the indi cator light starts to blink yellow this indicates that 90 of the filter life has been used and that the filters should be changed soon When the filters are changed reset the filter monitor by removing and re placing the battery The filt...

Страница 14: ...ull down e Install a new carbon and sediment filter in the indicated positions Use these replacement filters for PWC 9100F 1st stage Sediment filter P N TF 4113 2nd stage Carbon Block filter P N TF 4115 g Plug in the power cord Press cold dispense button and Let water run until it is clear 8 1 RO membrane Replacement With the cooler unplugged and the filter compartment open disconnect the 3 tubes ...

Страница 15: ...o wall so cooling fan isn t effective Refrigerant has leaked Move unit 6 inches away from wall Make sure intake vent is not blocked Contact dealer No Hot Water No Power Temperature control sen sor faulty First check that front Hot light is lit If not turn hot power switch on back Thermostatic controller on hot tank may not be functioning Check with dealer Unit Shut Off Panel Not Lit No Power Check...

Страница 16: ...uency Dimensions Weight empty Hot Water Tank Capacity Cold Water tank Capacity Power Consumption Electric Power Cord Length mkmk S516 AC110V L 16 x W 13 x H 16 1 2 42 lb 25 gal 1 0 gal Hot Water 500W Cold Water 100W 6Ft Conforms to UL STD 399 ...

Страница 17: ...O YEAR LIMITED WARRANTY PERIOD Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to purchaser WHAT IS COVERED BY THIS WARRANTY This limited warranty covers defects in materials or workmanship subject to the exclusions below and for the time period stated above Manufacturer promises to repair or to replace at Manufacturer s sole and abs...

Страница 18: ...arranty Manufacturer will provide parts to the Dealer at no charge labor is not included in this limited warranty The Dealer may in his or her sole and absolute discretion decide to repair the unit on site or take the unit to a shop to repair This limited warranty covers replacement or repair of parts only Manufacturer will not replace the entire unit if a part can be replaced or repaired to resto...

Страница 19: ...PWCM 4 08 15 Copyright 2009 VERTEX INDUSTRIALS INC ...

Отзывы: