6.0 Leak Detection System
11
This cooler is equipped with a mechanical leak detector and shut off valve.
It is located behind the filters in the base of the cabinet. If water leaks to the
bottom of the cooler, the leak detector valve will close and shut off the feed
water to the filters and the cooler. Once the leak is repaired, reset the leak de-
tector by replacing the activation sponge (a spare activation sponge is supplied
with the cooler) and resetting the activation lever to the open position (down).
NOTE: do not remove the plastic wrapping from the replacement cartridge–
install with bevel side down.
7.0 Filter Monitor Operation
When water is dispensed, the green indicator light will blink. When the indi-
cator light starts to blink yellow, this indicates that 90% of the filter life has been
used and that the filters should be changed soon.
When the filters are changed, reset the filter monitor by removing and re-
placing the battery. The filter monitor sensor and battery is located in the filter
compartment. The watch style battery is partially exposed and can be removed
by pulling on the battery with finger nails or pliers. Battery should be replaced
every year or 2nd filter change, whichever is first.
Reset
Normal ON position
Figure 9
Leak Detector
Activated cartridge: OFF position