1) The VAC-UNI (CD-58/PA-55) charges
only the Vertex Standard FNB-V127LI-UNI,
FNB-V128LI-UNI, FNB-V129LI-UNI and FNB-
V129LIIS-UNI Lithium-Ion Battery Pack.
2) If the IS version of the VX-P820 is being used in
a hazardous environment where Intrinsic Safety (IS)
is required you must use the FNB-V129LIIS-UNI
battery.
3) Use only the Vertex Standard PA-55 AC Adapter.
4) To reduce the risk of explosion, recharge the bat-
teries outside of hazardous locations.
5) Perform the battery charging where the ambient
temperature range +41 °F to +104 °F (+5 °C to +40
°C). Charge out of this range could cause damage to
the battery pack.
6) Battery Pack shall not be exposed to excessive
heat such as sunshine, fire, or the like.
7) Risk of explosion if battery is replaced by an in-
correct type. Dispose of used batteries according to
the instructions.
8) For further details and cautions of the charging,
refer to the Operating Manual of the CD-58 Desktop
Charger.