Required Test Equipment   

ˆ

  RF Signal Generator with calibrated output level at 200 MHz 

ˆ

  Deviation Meter (linear detector)   

ˆ

 AF 

Millivoltmeter 

 

ˆ

 SINAD 

Meter 

ˆ

  Inline Wattmeter with 5% accuracy at 200 MHz 

ˆ

  Regulated DC Power Supply: 0V to 10 VDC, 5A 

ˆ

  50-ohm Non-reactive Dummy Load: 10 W at 200 MHz 

ˆ

  Frequency Counter: > 0.1 ppm accuracy at 200 MHz 

ˆ

  AF Signal Generator   

ˆ

  DC Voltmeter: high impedance 

ˆ

  VHF Sampling Coupler 

ˆ

  AF Dummy Load: 16 Ohms, 1 W   

ˆ

 Oscilloscope 

ˆ

 Spectrum 

Analyzer 

ˆ

 HX100 

Marine 

Transceiver 

 

Alignment Preparation & Precautions 

A dummy load and inline wattmeter must be connected to the main antenna jack in all 

procedures that call for transmission. Correct alignment is not possible with an antenna.   

After completing one step, read the following step to determine whether the same test 

equipment will be required. If not, remove the test equipment (except dummy load and 

wattmeter, if connected) before proceeding. 

Correct alignment requires that the ambient temperature be the same as that of the 

transceiver and test equipment, and that this temperature be held constant between 68 °F 

and 86 °F (20 °C and 30 °C). When the transceiver is brought into the shop from hot or cold 

air it should be allowed some time for thermal equalization with the environment before 

alignment. If possible, alignments should be made with oscillator shields and circuit boards 

firmly affixed in place. Also, the test equipment must be thoroughly warmed up before 

beginning. 

Note: 

Signal levels in dB referred to in this procedure are based on 0 dBµ = 0.5 µV 

(closed circuit). 

 

Содержание HX100

Страница 1: ...complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of Yaesu Musen must reserve the right to change circuits an...

Страница 2: ...smission Correct alignment is not possible with an antenna After completing one step read the following step to determine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this tempe...

Страница 3: ...ect the wattmeter and 50 ohm dummy load to the antenna jack Press the SCAN DW key till HI is displayed Press or keys while pressing the PTT key to set the power to 2 4 0 1W Press VOL SQL key to fix the alignment data Adjustment of TX Low Power Connect the wattmeter and 50 ohm dummy load to the antenna jack Press the SCAN DW key till Lo is displayed Press or keys while pressing the PTT key to set t...

Страница 4: ...h tight level Press VOL SQL key to fix the alignment data Adjustment of the Squelch Threshold Connect the RF signal generator to the antenna jack Set the output frequency at 156 8000MHz with standard modulation 3 0kHz deviation 1kHz modulation Set the output level to 7dBµ Press the SCAN DW key till tH is displayed Press PRESET key to obtain the squelch threshold level Press VOL SQL key to fix the ...

Отзывы: