background image

FCC ID: K66GX1255S

Alignment

Vertex Standard Co,. Ltd.

5

!

 

Set the channel to EXP02

EXP02

EXP02

EXP02, confirm that maximum deviation is between ±4.3 KHz

and ±5.0 KHz.

!

 

Set the channel to EXP04

EXP04

EXP04

EXP04, confirm that maximum deviation is between ±4.0 KHz

and ±5.0 KHz.

!

 

Set the channel to EXP05

EXP05

EXP05

EXP05, confirm that maximum deviation is between ±4.0 KHz

and ±5.0 KHz.

Adjustment of Receiver Front-end

Adjustment of Receiver Front-end

Adjustment of Receiver Front-end

Adjustment of Receiver Front-end
Adjust the receiver front-end coil.
-- Adjustment --

!

 

Setup the test equipment as shown below.

!

 

Set the center frequency of t he spectrum analyzer to 159.00 MHz, set SPAN to
20.00 MHz, set RBW and VBW to 30 KHz, and set SWP to 56 ms.

!

 

Adjust 

T1001

T1002

T1003

T1004

, and 

T1005

 until the wave form shown in

below is obtained.

Note

Note

Note

Note: Adjust the output of the tracking generator so that  RF AMP and spectrum
analyzer will not saturate.
Figure shows the reference wave form. The wave form varies with measuring
instruments. It is impotent to take the lowest possible value at the stop band near 150
MHz and the highest possible value at the band near 156 MHz.
Each coil shall be adjusted at the range between the initial condition and right and left
revolving.

GX1255S-FRONT-END

ATTEN 20dB 

RL 10.0dBm

10dB/

CENTER  159.00 MHz

 

*RBW  30 kHz

VBW  30 kHz

SPAN  20.00 MHz

SWP  56.0 ms

Содержание GX1255S

Страница 1: ...replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change circuits and alignment procedures in the interest of improved performance without notifyin...

Страница 2: ...t except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed some time for thermal equalization with the environmen...

Страница 3: ... of VCO Confirmation of VCO Confirmation Connect the DC voltmeter to the test point LOCK TP Use the UP DOWN key to set the channel to EXP04 EXP04 EXP04 EXP04 confirm that voltage on the test point is over 1 0 V in the receive and transmit mode Use the UP DOWN key to set the channel to EXP05 EXP05 EXP05 EXP05 confirm that voltage on the test point is below 5 0 V in the transmit mode Use the UP DOWN...

Страница 4: ...uency in the transmit mode and local frequency in the receive mode Adjustment Setup the test equipment as shown below Set the channel to CH16 CH16 CH16 CH16 With the PTT switch pressed adjust TC1001 so that RF frequency is 156 80000 MHz 50 Hz Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Dev...

Страница 5: ...n below Set the center frequency of t he spectrum analyzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust T1001 T1002 T1003 T1004 and T1005 until the wave form shown in below is obtained Note Note Note Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form ...

Страница 6: ...ata Confirmation of receiver NMEA data Confirmation of receiver NMEA data Confirmation of receiver NMEA data Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the...

Страница 7: ...at 123456780 of conformation transceiver s MMSI is displayed in the LCD of the test transceiver Confirm that the conformation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the conformation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the conformation transceiver ...