background image

FCC ID: K66GX1255S

Alignment

Vertex Standard Co,. Ltd.

2

!

 

SINAD Meter

!

 

Inline Wattmeter with 5% accuracy at 200 MHz

!

 

Regulated DC Power Supply: 13.8 VDC, 10A

!

 

50-ohm Non-reactive Dummy Load: 30W at 200 MHz

!

 

Frequency Counter: >0.1 ppm accuracy at 200 MHz

!

 

AF Signal Generator

!

 

DC Voltmeter: high impedance

!

 

VHF Sampling Coupler

!

 

AF Dummy Load: 4 Ohms, 10 W

!

 

Oscilloscope

!

 

Spectrum Analyzer

!

 

GX1260S Marine Transceiver

Alignment Preparation & Precautions

Alignment Preparation & Precautions

Alignment Preparation & Precautions

Alignment Preparation & Precautions

A dummy load and inline wattmeter must be connected to the main antenna jack in

all procedures that call for transmission. Correct alignment is not possible with an
antenna.

After completing one step, read the following step to determine whether the same

test equipment will be required. If not, remove the test equipment (except dummy load
and wattmeter, if connected) before proceeding.

Correct alignment requires that the ambient temperature be the same as that of the

transceiver and test equipment, and that this temperature be held constant between
20°C and 30°C (68°F and 86°F). When the transceiver is brought into the shop from
hot or cold air it should be allowed some time for thermal equalization with the
environment before alignment. If possible, alignments should be made with oscillator
shields and circuit boards firmly affixed in place. Also, the test equipment must be
thoroughly warmed up before beginning.

Note: Signal levels in dB referred to in this procedure are based on 0 dBµ = 0.5 µV
(closed circuit).

Overview of Test Mode

Overview of Test Mode

Overview of Test Mode

Overview of Test Mode

The test mode has been build in the microprocessor in order to adjust and confirm

the performance of transceiver.

The purpose is to adjust transceiver simply and to confirm the performance of

transceiver smoothly.

(a) Expansion channels “EXP01 - EXP06” will be set as follows:

Содержание GX1255S

Страница 1: ...replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change circuits and alignment procedures in the interest of improved performance without notifyin...

Страница 2: ...t except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed some time for thermal equalization with the environmen...

Страница 3: ... of VCO Confirmation of VCO Confirmation Connect the DC voltmeter to the test point LOCK TP Use the UP DOWN key to set the channel to EXP04 EXP04 EXP04 EXP04 confirm that voltage on the test point is over 1 0 V in the receive and transmit mode Use the UP DOWN key to set the channel to EXP05 EXP05 EXP05 EXP05 confirm that voltage on the test point is below 5 0 V in the transmit mode Use the UP DOWN...

Страница 4: ...uency in the transmit mode and local frequency in the receive mode Adjustment Setup the test equipment as shown below Set the channel to CH16 CH16 CH16 CH16 With the PTT switch pressed adjust TC1001 so that RF frequency is 156 80000 MHz 50 Hz Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Deviation Adjustment and Confirmation of Dev...

Страница 5: ...n below Set the center frequency of t he spectrum analyzer to 159 00 MHz set SPAN to 20 00 MHz set RBW and VBW to 30 KHz and set SWP to 56 ms Adjust T1001 T1002 T1003 T1004 and T1005 until the wave form shown in below is obtained Note Note Note Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form ...

Страница 6: ...ata Confirmation of receiver NMEA data Confirmation of receiver NMEA data Confirmation of receiver NMEA data Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the...

Страница 7: ...at 123456780 of conformation transceiver s MMSI is displayed in the LCD of the test transceiver Confirm that the conformation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the conformation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the conformation transceiver ...

Отзывы: