background image

FCC ID: K6630303X3S 

IC ID: 511B-30303X3S 

Alignment 

3/6

 

Vertex Standard Co,. Ltd. 

(A)  In CH70, every time you are in transmit mode, (every time you press PTT), the 

following test tone can be outputted: 

1st transmission:  1300 Hz 

2nd transmission: 2100 Hz 

3rd transmission:  No modulation 

4th transmission:  Synthetic tone of 1300 Hz and 2100 Hz  

5th transmission:  Return to 1st transmission 

(B)  Scan the channels between WX10 and EXP04 in the SCAN mode. 

 

Starting Test Mode 

Confirm that 

PWR/VOL

 switch is off, and short the TEST points(JP1001). Turn on the 

PWR/VOL

 switch while press and holding the 

DIST

 and 

W/X

 keys. 

 

Adjustment and Confirmation of Transmit Power 

Adjust power at high and low in the transmit mode, and confirm power in the specified 

bandwidth. 

-- Adjustment -- 

ˆ

  Connect the wattmeter and 50-ohm dummy load to the antenna jack. 

ˆ

 Use 

the 

H/L

 key to set transceiver to 

high power

 and set the channel to 

CH16

. With 

the 

PTT

 switch pressed, adjust 

VR1001

 so that RF power is 25 W. 

ˆ

 Use 

the 

H/L

 key to set transceiver to 

low power

 and set the channel to 

CH16

. With 

the 

PTT

 switch pressed, adjust 

VR1002

 so that RF power is 0.8 W. 

 

Adjustment of PLL Frequency 

Adjust the frequency in the transmit mode and local frequency in the receive mode. 

ˆ

  Setup the test equipment as shown below. 

ˆ

  Set the channel to 

CH16

. With the 

PTT

 switch pressed, adjust 

TC1001

 so that RF 

frequency is 156.80000 MHz ± 100 Hz. 

 

Adjustment and Confirmation of Deviation 

Adjust deviation in the transmit mode. 

-- Adjustment -- 

ˆ

  Setup the test equipment as shown below. 

ˆ

  Set the channel to 

CH16

ˆ

  Set the output of the audio generator (AG) to 1 kHz and 200 mV. 

ˆ

 With 

the 

PTT

 switch pressed, adjust 

VR1003

 so that the maximum deviation is ±4.2 

kHz. 

 

 

 

Содержание GX1000S

Страница 1: ...make complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of VERTEX STANDARD must reserve the right to change ci...

Страница 2: ...etermine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 C and 30 C 68 F and 86 F When the transceiver is brought into the shop from ho...

Страница 3: ...idth Adjustment Connect the wattmeter and 50 ohm dummy load to the antenna jack Use the H L key to set transceiver to high power and set the channel to CH16 With the PTT switch pressed adjust VR1001 so that RF power is 25 W Use the H L key to set transceiver to low power and set the channel to CH16 With the PTT switch pressed adjust VR1002 so that RF power is 0 8 W Adjustment of PLL Frequency Adju...

Страница 4: ...ave form shown in below is obtained Note Adjust the output of the tracking generator so that RF AMP and spectrum analyzer will not saturate Figure shows the reference wave form The wave form varies with measuring instruments It is impotent to take the lowest possible value at the stop band near 150 MHz and the highest possible value at the band near 156 MHz Each coil shall be adjusted at the range...

Страница 5: ... Input NMEA format data output from GPS receiver to NMEA terminal A of transceiver and display it to the LCD of the transceiver NMEA format data output from GPS receiver is applied to NMEA terminal of transceiver s option connector and LCD of transceiver will show data Confirmation Setup the test equipment as shown below Press and hold the H L key confirm that the position data is displayed on the...

Страница 6: ...I is displayed in the LCD of the test transceiver Confirm that the confirmation transceiver receives the response from the test transceiver and outputs beep Press the CALL SET key of the confirmation transceiver and turn off the beep Simultaneously confirm that TEST of test transceiver s MMSI is displayed in the LCD of the confirmation transceiver ...

Отзывы: