EVX-531 UHF Service Manual
14
3. rx s
ensitivity
(rx t
une
)
This parameter is to align the RX BPF (Band Pass Filter) for Receive (RX) sensitivity. The PLL Reference Frequency (Frequency)
alignment must be done before this alignment is performed.
1. Click the “RX Tune” button to open the “RX Sensitivity Align-
ment” window.
2. Click the “Auto” button on the desired channel. The “Auto
Tuning” window will appear.
3. Set the RF Signal Generator output according to the indication
of the screen.
4. Click the “Start” button to start the automatic alignment to get
the best RX sensitivity (Highest RSSI value).
5. Click the “OK” button to finish the RX Sensitivity alignment
and save the data.
1) You may adjust the RX sensitivity manually by the following
method:
l
Dragging the slide bar
l
Clicking the arrow buttons
l
Pressing the left/right arrow key of the computer’s keyboard
l
Entering the value (“800”- “FFF”) in the “Current Data”
box from the computer’s keyboard
2) You may select the alignment type from the “Radio” button
(
ADJ Type
) located at the bottom of the screen, as needed.
Basic
:
“Low-edge / band center / high-edge” and select the
channel for alignment (Default).
Single
: Alignment value changes only on the selected chan-
nel.
All Freq
: Alignment value changes on all channels.
Alignment
ê
ê
Содержание EVX-531
Страница 8: ...EVX 531 UHF Service Manual Block Diagram 8 ...
Страница 24: ...EVX 531 UHF Service Manual 24 MAIN Unit Type G7 w o Option Connector Circuit Diagram FR024460D RF Sections ...
Страница 27: ...EVX 531 UHF Service Manual 27 MAIN 2 Unit Type G6 w o Option Connector Circuit Diagram FR025510A RF Sections ...