14
( NOTE: When you find error codes, first check the operation of the stove and its
components). You will see "BLOCK" on the screen. After checking and correcting the
following connection, parts and values according to the error code, the error code should
be cleared by pressing P2 for 3 seconds. When the error code clears, contact your dealer
for any remaining malfunctions.
Error
code
Explanation
Solution
Er01
Safety limit thermostat error
- fuel chamber overheating
(more than 90°)
On the first screen when the stove display starts
to work, you can find ER01. Press
the button
to clear the error code. Check sanitary valves and
pump. Push in the black prong of the safety limit
thermostat, located on the back of the boiler. (see
page 9)
Er02
Chimney emission safety
switch error
Check stack connections and stack emissions.
Make sure the chimney and second ashtray are
clean
Er03
Drop in stack outlet
temperature or auger failure
Check if there is fuel in the combustion chamber
and if the fuel is supplied by the auger.
Er04
Boiler water temperature
overheating
Check if the sanitary valves are open and if the
pump works. Bleed air from radiators.
Er05
Chimney outlet over-
temperature error / smoke
temperature sensor error or
cleaning error
This error occurs when the calibration values are
increased or when the general cleaning time is
reached. Please do a general cleaning of the
product.
Er07
Stack Emission Fan Motor
Error
Check that your chimney is not clogged and
restart it. Make sure the chimney and second
ashtray are clean. If the error persists, contact
your dealer.
Er08
Stack Emission Fan Motor
Encoder Error
Reset the alarm and if the error persists, contact
your dealer.
Er09
Low pressure in the boiler
water
Check the manometer and in case of low pressure
supply water to the hydraulic circuit.
Er10
High pressure in boiler water
Check the pressure gauge and make sure the
water pressure is in the range of 1-1.5 bar. If the
pressure is high, reduce the pressure by
Содержание COMPACT HIDRO 16
Страница 11: ...11 PUNTO DE CONEXIÓN DEL TERMOSTATO AMBIENTE ...
Страница 23: ...23 6 1 LIMPIEZA DE TUBOS DE LLAMA GAIA HIDRO 16 LEONORA HIDRO 24 COMPACT HIDRO 16 COMPACT HIDRO 24 EJEMPLO ...
Страница 32: ...USER MANUAL PELLETS STOVE HIDRO GAIA HIDRO 16 LEONORA HIDRO 24 COMPACT HIDRO 16 COMPACT HIDRO 24 EN ...
Страница 42: ...11 ROOM THERMOSTAT CONNECTION POINT ...
Страница 53: ...22 6 1 FLAME TUBES CLEANING GAIA HYDRO 16 LEONORA HYDRO 24 COMPACT HYDRO 16 COMPACT HYDRO 24 EXAMPLE ...
Страница 62: ...MANUAL DE USO SALAMANDRA DE PELLETS HIDRO GAIA HIDRO 16 LEONORA HIDRO 24 COMPACT HIDRO 16 COMPACT HIDRO 24 PT ...
Страница 72: ...11 PONTO DE CONEXÃO DO TERMÓSTATO DA SALA ...
Страница 84: ...23 6 1 LIMPEZA DOS TUBOS DE CHAMA GAIA HIDRO 16 LEONORA HIDRO 24 COMPACTO HIDRO 16 HIDRO COMPACTO 24 EXEMPLO ...
Страница 93: ...Página 4de 4 store eiderbiomasa com www eiderbiomass com ...