background image

 
 

 

www.versitron.com 

 
 

 

 1   DESCRIPTION OF EQUIPMENT 

 

 1.1   INTRODUCTION 

 

This manual provides general and detailed information on the installation and operation of 

the Model F271XA Fiber-Optic Telephone Modem.  Section  1  provides a general description of 
the  equipment.    Section    2    provides  installation  instructions.    Section    3    provides  operating 
instructions.  Section  4  provides the theory of operation.  Section  5  provides maintenance and 
troubleshooting  information.    Figure  1  and  Figure  2  provide  an  overall  view  of  the  Telephone 
Modems.

 

 

 

 

 

 

 

Figure 1: Front View, F271XA (Top Unit) 

 

Figure 2: Rear View, F271XA 

Содержание F270XA

Страница 1: ...F271XA Fiber Optic Telephone Modem Technical Manual Revision B August 2011 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com Safeguarding Communications Since 1958...

Страница 2: ...arranty does not cover damage to products caused by misuse mishandling power surges accident improper installation neglect alteration improper maintenance or other causes which are not normal and cust...

Страница 3: ...ne Modem Section 1 provides a general description of the equipment Section 2 provides installation instructions Section 3 provides operating instructions Section 4 provides the theory of operation Sec...

Страница 4: ...e converse occurs in the other direction for the F271XA The telephone modem transmits analog signals of 300 to 3400Hz 1 2 3 Physical Characteristics The telephone modems measure 7 0 wide x 0 84 high x...

Страница 5: ...3 x 48 0 x 35 0 cm 2 Slot Rack Mount Chassis Side by Side PSAC08 PSAC09 LTWPD1210PLX LTWPD1210EPL HF 20A 32406 7 0 H x 19 0 W x 11 6 D 17 8 x 48 0 x 29 5 cm 20 Slot Rack Mount Chassis AC300WR 32410 VM...

Страница 6: ...Twisted Pair Audio Signal Analog 300Hz to 3 4Khz Idle Channel Noise 65dBm Single Frequency Distortion 46dB 2nd Harmonic Distortion 55dB Talk Battery 44 to 52 VDC Loop Current 40mA max off hook Ring S...

Страница 7: ...at the copper and fiber optic cables are not mechanically separated from the modem during operation When installed in either desktop chassis or in the dual card rack mount chassis space for the power...

Страница 8: ...nge 2 3 3 Default Jumper The remaining jumper J1 is open and should not be changed 2 4 Power Requirements The F271XA products are designed to operate from an AC power transformer or a DC power source...

Страница 9: ...in a standalone or dual card rack mount chassis a power transformer is plugged into barrel jack J3 When installing the Telephone Modem in a 20 Slot rack mount chassis HF 20Aor VMX20 with optional pow...

Страница 10: ...click into place 2 6 Initial Checkout Procedure F271XA telephone modems contain no power on off switch Once power is connected the Modem will go through its power up sequence When the System LED see...

Страница 11: ...here are five indicators used on the F271XA Link Status Link Transmit Data TX Receive Data RX System Status System and a multi function LED for the telephone port see Table 7 for descriptions Table 7...

Страница 12: ...an alarm circuit Therefore the Alarm signal on the P1 connector will not be driven by this unit 4 3 Functional Description The unit consists of the following circuits 4 3 1 Ring Detection 4 3 2 Ring...

Страница 13: ...phone CODEC chipset 4 3 5 Fiber Optic Transceiver Circuit Fiber optic communications are handled by the SFP module The power for this module is isolated from the other power circuits through filters T...

Страница 14: ...current condition Power off the unit for a few minutes and retry Other Contact VERSITRON for assistance Link Status Link LED is OFF Incorrect optical signal level received at receiver input 1 Check t...