 5   MAINTENANCE AND TROUBLESHOOTING 

 

 5.1   Introduction 

 

This chapter contains  general information designed to isolate a malfunction in the Model 

F271XA to a replaceable unit.  These units are not equipped with redundancy.  Therefore, a failure 
in one of these units would interrupt service. 

 

 5.2   Fault Isolation 

 

  The  steps  in  Table  8  should  be  taken  to  check  a  non-operating  modem.  Contact 

VERSITRON  Customer  Service  for  additional  diagnostic  assistance  or  to  arrange  for  repair  as 
necessary. 
 

Table 8: Non-Operational Indicators 

STATUS INDICATOR 

PROBABLE CAUSE 

CORRECTIVE ACTION 

System Status (System) LED is 
OFF 

No AC power 

Check that both ends of the transformer are 
connected 

Over current condition 

Power off the unit for a few minutes and retry 

Other 

Contact VERSITRON for assistance 

Link Status (Link) LED is OFF 

Incorrect optical signal level received at 
receiver input 

1.

 

Check that fiber-optic cables are properly 
connected 

2.

 

Check that the remote unit power is on and the 
fiber-optic connectors are properly attached 

3.

 

Check that the SFP module on each end is 
seated properly 

4.

 

Contact VERSITRON for assistance 

Ports Indicator LED is ON 

Possible problems ranging from a 
telephone set in an Off-Hook position to 
a problem with the Off-Hook circuit 

Check if the telephone set receiver is seated in the 
cradle correctly. If this is not the case, contact 
VERSITRON for assistance   

Modem is not working properly 

Default jumpers and switch settings are 
not set properly 

1.

 

Check if SW1 positions are all off 

2.

 

Check that jumper J2 is off 

3.

 

Contact VERSITRON for assistance 

 

Содержание F270XA

Страница 1: ...F271XA Fiber Optic Telephone Modem Technical Manual Revision B August 2011 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com Safeguarding Communications Since 1958...

Страница 2: ...arranty does not cover damage to products caused by misuse mishandling power surges accident improper installation neglect alteration improper maintenance or other causes which are not normal and cust...

Страница 3: ...ne Modem Section 1 provides a general description of the equipment Section 2 provides installation instructions Section 3 provides operating instructions Section 4 provides the theory of operation Sec...

Страница 4: ...e converse occurs in the other direction for the F271XA The telephone modem transmits analog signals of 300 to 3400Hz 1 2 3 Physical Characteristics The telephone modems measure 7 0 wide x 0 84 high x...

Страница 5: ...3 x 48 0 x 35 0 cm 2 Slot Rack Mount Chassis Side by Side PSAC08 PSAC09 LTWPD1210PLX LTWPD1210EPL HF 20A 32406 7 0 H x 19 0 W x 11 6 D 17 8 x 48 0 x 29 5 cm 20 Slot Rack Mount Chassis AC300WR 32410 VM...

Страница 6: ...Twisted Pair Audio Signal Analog 300Hz to 3 4Khz Idle Channel Noise 65dBm Single Frequency Distortion 46dB 2nd Harmonic Distortion 55dB Talk Battery 44 to 52 VDC Loop Current 40mA max off hook Ring S...

Страница 7: ...at the copper and fiber optic cables are not mechanically separated from the modem during operation When installed in either desktop chassis or in the dual card rack mount chassis space for the power...

Страница 8: ...nge 2 3 3 Default Jumper The remaining jumper J1 is open and should not be changed 2 4 Power Requirements The F271XA products are designed to operate from an AC power transformer or a DC power source...

Страница 9: ...in a standalone or dual card rack mount chassis a power transformer is plugged into barrel jack J3 When installing the Telephone Modem in a 20 Slot rack mount chassis HF 20Aor VMX20 with optional pow...

Страница 10: ...click into place 2 6 Initial Checkout Procedure F271XA telephone modems contain no power on off switch Once power is connected the Modem will go through its power up sequence When the System LED see...

Страница 11: ...here are five indicators used on the F271XA Link Status Link Transmit Data TX Receive Data RX System Status System and a multi function LED for the telephone port see Table 7 for descriptions Table 7...

Страница 12: ...an alarm circuit Therefore the Alarm signal on the P1 connector will not be driven by this unit 4 3 Functional Description The unit consists of the following circuits 4 3 1 Ring Detection 4 3 2 Ring...

Страница 13: ...phone CODEC chipset 4 3 5 Fiber Optic Transceiver Circuit Fiber optic communications are handled by the SFP module The power for this module is isolated from the other power circuits through filters T...

Страница 14: ...current condition Power off the unit for a few minutes and retry Other Contact VERSITRON for assistance Link Status Link LED is OFF Incorrect optical signal level received at receiver input 1 Check t...

Отзывы: