background image

e1nmdlCsmATEX-rev0614

www

.

versamatic

.

com

Model E1 Non-Metallic Bolted • 

2

Materials

Material Profile:

Operating  

Temperatures:

Max.

Min.

Conductive Acetal: Tough, impact resistant, ductile. Good 

abrasion resistance and low friction surface. Generally inert, with 

good chemical resistance except for strong acids and oxidizing 

agents.

190°F

88°C

-20°F

-29°C

EPDM: Shows very good water and chemical resistance. Has 

poor resistance to oils and solvents, but is fair in ketones and 

alcohols.

280°F

138°C

-40°F

-40°C

FKM: (Fluorocarbon) Shows good resistance to a wide range  

of oils and sovents; especially all aliphatic, aromatic and  

halogenated hydrocarbons, acids, animal and vegetable oils. 

Hot water or hot aqueous solutions (over 70°F) will attack FKM.

350°F

177°C

-40°F

-40°C

Hytrel®: Good on acids, bases, amines and glycols at room 

temperatures only.

220°F

104°C

-20°F

-29°C

Neoprene: All purpose. Resistance to vegetable oils. Generally 

not affected by moderate chemicals, fats, greases and many 

oils and solvents. Generally attacked by strong oxidizing acids, 

ketones, esters and nitro hydrocarbons and chlorinated aromatic 

hydrocarbons.

200°F

93°C

-10°F

-23°C

Nitrile: General purpose, oil-resistant. Shows good solvent, oil, 

water and hydraulic fluid resistance. Should not be used with 

highly polar solvents like acetone and MEK, ozone, chlorinated 

hydrocarbons and nitro hydrocarbons.

190°F

88°C

-10°F

-23°C

Nylon: 6/6 High strength and toughness over a wide  

temperature range. Moderate to good resistance to fuels, oils 

and chemicals.

180°F

82°C

32°F

0°C

Polypropylene: A thermoplastic polymer. Moderate tensile 

and flex strength. Resists stong acids and alkali. Attacked by 

chlorine, fuming nitric acid and other strong oxidizing agents.

180°F

82°C

32°F

0°C

PVDF:

 (Polyvinylidene Fluoride) A durable fluoroplastic with 

excellent chemical resistance. Excellent for UV applications. 

High tensile strength and impact resistance.

250°F

121°C

0°F

-18°C

Santoprene®: Injection molded thermoplastic elastomer with 

no fabric layer. Long mechanical flex life. Excellent abrasion 

resistance.

275°F

135°C

-40°F

-40°C

UHMW PE: A thermoplastic that is highly resistant to a broad 

range of chemicals. Exhibits outstanding abrasion and impact 

resistance, along with environmental stress-cracking resistance.

180°F

82°C

-35°F

-37°C

Urethane: Shows good resistance to abrasives. Has poor 

resistance to most solvents and oils.

150°F

66°C

32°F

0°C

Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious. 

Very few chemicals are known to chemically react with PTFE; 

molten alkali metals, turbulent liquid or gaseous fluorine and 

a few fluoro-chemicals such as chlorine trifluoride or oxygen 

difluoride which readily liberate free fluorine at elevated 

 

temperatures.

220°F

104°C

-35°F

-37°C

Maximum and Minimum Temperatures are the limits for which these materials can be operated. 

Temperatures coupled with pressure affect the longevity of diaphragm pump components. 

Maximum life should not be expected at the extreme limits of the temperature ranges.

Metals:

Alloy C:

 Equal to ASTM494 CW-12M-1 specification for nickel and nickel alloy.

Stainless Steel: 

Equal to or exceeding ASTM specification A743 CF-8M for corrosion 

resistant iron chromium, iron chromium nickel and nickel based alloy castings for  

general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.

For specific applications, always consult the Chemical Resistance Chart.

CAUTION! 

Operating temperature limitations are as follows:

AFTERMARKET PARTS

Pumper Parts

 is your single source for parts that 

fit Air-Operated Double Diaphragm (AODD) pumps

     • Wilden

®

     • ARO

®

     • Yamada

®

 

RIGHT PART, RIGHT NOW

Designed to perform equal to or greater 
than original equipment manufacture.

Phone: (419) 526-7296

info@pum perparts.com

www.pumperparts.com

Pumper Parts and its products are not affiliated with any of the original equipment manufacturers referenced herein. All original equipment manufacturers’ names, colors, pictures, descriptions and part numbers are used for identification 

purposes only. Pumper Parts

®

 is a registered trade name of IDEX Corporation. All other trademarks, registered trademarks and product names are the property of their respective owners. 

Yamada

®

 is a registered trademark of 

Yamada Corporation. ARO

®

 is a registered trade name of Ingersoll-Rand Company. 

Wilden

®

 is a registered trade name of Wilden Pump and Engineering Company, a Dover Resources Company. 

MODEL SPECIFIC

UNIVERSAL ALL AODD

1: PUMP

 SPECS

Содержание E Series

Страница 1: ...allic Center Sections E1 VERSA MATIC Warren Rupp Inc A Unit of IDEX Corporation 800 North Main Street Mansfield OH 44902 USA Phone 419 526 7296 www versamatic com Copyright 2014 Warren Rupp Inc All rights reserved Service Operating Manual 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 WARRANTY Original Instructions ...

Страница 2: ...mperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonmetallic pumps and plastic components are not UV stabilized Ultraviolet radiation can damage these parts and negatively affect material properti...

Страница 3: ...ngs SECTION 2 INSTALLATION OPERATION 5 Principle of Pump Operation Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 8 Composite Drawings Parts List Materials Code SECTION 4 WARRANTY CERTIFICATES 10 Warranty EC Declaration of Conformity Machinery EC Declaration of Conformity ATEX 1 PUMP SPECS 2 INSTAL OP 3 EXP VIEW 4 WARRANTY ...

Страница 4: ...______________________________ VERSA MATIC MODEL IDENTIFICATION CODES X X X X X X X X X X X X X Model Pump Size Wetted Parts Non Wetted Parts Diaphragm Material Diaphragm Series Valve Ball Material Valve Seat Material Valve Seat O ring Material Construction Design Revision Level Options if applicable Model Pump Size Wetted Parts Non Wetted Parts Diaphragm Material E Elima Matic 6 1 4 A Aluminum A ...

Страница 5: ...s highly resistant to a broad range of chemicals Exhibits outstanding abrasion and impact resistance along with environmental stress cracking resistance 180 F 82 C 35 F 37 C Urethane Shows good resistance to abrasives Has poor resistance to most solvents and oils 150 F 66 C 32 F 0 C Virgin PTFE PFA TFE Chemically inert virtually impervious Very few chemicals are known to chemically react with PTFE...

Страница 6: ...rying hydraulic conditions may result in deviations in excess of 5 0 20 40 60 80 100 120 140 Discharge Head in PSI Meters Feet 240 220 200 180 160 140 120 100 80 60 40 20 0 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Capacity in Liters Per Minute Capacity in U S Gallons Per Minute 0 20 40 60 80 100 0 5 10 15 20 25 30 35 40 5 10 20 30 AIR CONSUMPTION IN SCFM AIR PRESSURE IN PSI SCFM M3 HR 5 8 5 1...

Страница 7: ... 49 12 45 9 81 249 22 8 13 206 38 1 ANSI 150 DIN 325 DISCHARGE FLANGE 1 ANSI 150 DIN 325 SUCTION FLANGE 1 2 NPT AIR EXHAUST 4 12 104 65 5 13 130 30 5 50 139 70 7 16 181 86 1 66 42 16 R 25 6 35 BOTTOM VIEW 13 52 343 41 11 48 291 47 16 94 430 15 3 8 NPT AIR INLET N 325 NGE 16 94 430 15 2 50 63 50 14 75 374 65 49 12 45 9 81 249 22 8 13 206 38 1 ANSI 150 DIN 325 DISCHARGE FLANGE 1 ANSI 150 DIN 325 SUC...

Страница 8: ...sure P4 to push the fluid through the suction piping and across the suction side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pulled through its stroke The diaphragm s inner plate makes contact with an actuator plunger aligned to shift the pilot si...

Страница 9: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to increase air flow as desired If opening the valve increases cycling rate but does not increase the rate of flow cavitation has occurred The v...

Страница 10: ...eets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Check suction move pump closer to product Lack of air line size PSI CFM Check the air line size length compressor capacity Excessive suction lift For lifts exceeding 20 of liquid filling the chamber...

Страница 11: ...PTFE TWO PIECE DIAPHRAGM ASY 37 40 38 41 38 40 41 39 35 36 Torque Setting 180 in lbs Torque Setting 120 in lbs Torque Setting 180 in lbs Torque 120 in Torque Setting 180 in lbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 10 17 18 19 20 22 23 24 25 25 26 27 28 29 30 31 32 33 34 29 29 10 19 35 36 Torque Setting 120 in lbs Torque Setting 180 in lbs Torque Setting 120 in lbs Torque Setting 180 in lbs Torqu...

Страница 12: ...ragm Assembly Elastomers Item Qty Description Part Number TPE RUBBER PTFE 2 Piece PTFE Fusion 18 2 Main Shaft O Ring P50 403 19 1 Main Shaft 685 V001 120 P50 108 20 2 Diaphragm V183xx 1 See Below Material Chart V183TF 1 V183F 21 2 Back Up Diaphragm N A V183TB N A 22 2 Inner Diaphragm Plate V181C N A 23 2 Outer Diaphragm Plate PE113 PV181TO N A 24 4 Valve Seat O Ring V90xx See Below Material Chart ...

Страница 13: ... Directivas comunitárias MANUFACTURED BY FABRIQUE PAR FABRICADA POR HERGESTELLT VON FABBRICATO DA VERVAARDIGD DOOR TILLVERKAD AV FABRIKANT VALMISTAJA PRODUSENT FABRICANTE DECLARATION DE CONFORMITE DECLARACION DE CONFORMIDAD ERKLÄRUNG BEZÜGLICH EINHALTUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMITÀ CONFORMITEITSVERKLARING DEKLARATION OM ÖVERENSSTÄMMELSE EF OVERENSSTEMMELSESERKLÆRING VAATIMUSTENMUK...

Страница 14: ...nder 1051 6825 MJ Arnhem The Netherlands Harmonized Standards Applied EN 13463 1 2009 Non Electrical Equipment Potentially Explosive Atmospheres Part 1 Basic Methods and Requirements EN 13463 5 2011 Non Electrical Equipment for Potentially Explosive Atmospheres Part 5 Protection by Constructional Safety Equipments 1 Elima Matic Series with any of the following materials of construction are rated t...

Отзывы: