background image

9

gas  connection

Gas supply line

Shutoff valve

“open” position

To range

Explosion Hazard

Use a new CSA or UL approved 
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water 
column.
Examples  of  a  qualified  person 
include  licensed  heating  per-
sonnel,  authorized  gas  compa-
ny  personnel,  and  authorized 
service personnel.
Failure  to  do  so  can  result  in 
death, explosion, or fire.

Fig. 2.1

All  gas  connections  must  be  made  according  to  national  and  local  codes.  This 

gas  supply  (service)  line  must  be  the  same  size  or  greater  than  the  inlet  line  of  the 

appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas.

The  range  is  equipped  for  the  use  with  NATURAL  gas.  It  is  design-certified  by  CSA 

International  for  NATURAL  and  L.P.  gases  with  appropriate  conversion.
The  model/serial  rating  plate,  located  inside  the  drawer,  has  information  on  the  type 

of  gas  that  can  be  used.  If  this  information  does  not  agree  with  the  type  of  gas 

available,  check  with  the  local  gas  supplier.  See  page  from  13  to  16  for  L.P.  gas 

conversion  instructions.

1.  Manual  Shut-off  Valve 

(fig: 2.1)

:

A  manual  shut-off  valve  must  be  installed  in  an  accessible  location  in  the  gas  line 

external  to  the  appliance  for  the  purpose  of  turning  on  or  shutting  off  gas  to  the 

appliance  (In  Massachusetts  such  shutoff  devices  should  be  approved  by  the  Board 

of  State  Examiners  of  Plumbers  &  Gas  Fitters).  This  valve  should  be  located  in  the 

same room as the range and should be in a location that allows ease of opening and 

closing (in a position where it can be reached quickly in the event of an emergency).
Do  not  block  access  to  the  shutoff  valve.  The  valve  is  for  turning  on  or  shutting  off 

gas  to  the  appliance.

2.  Pressure  Regulator:

a)   All heavy duty, commercial type cooking equipment must have a pressure regulator 

on the incoming service line for safe and efficient operation, since service pressure 

may  fluctuate  with  local  demand. 

  Before installing the regulator mount the 1/2” NPT (conical) male connector to the 

regulator  (see  picture  2.2).  Gasket  supplied  have  to  be  placed  between  1/2”  NPT 

(conical)  connector/extension  pipe  male  pipe  fitting  (see  picture  2.3).

  The regulator supplied with this range must be installed before any gas connections 

are  made.

  Use  supplied  pressure  regulator  only.

Содержание VEFSGG 244

Страница 1: ...ty Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Hom...

Страница 2: ...ighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Страница 3: ...f domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is...

Страница 4: ...lified installer service agent or the gas supplier IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NE...

Страница 5: ...lation should comply with national and local codes 11 Air Supply and Ventilation The installer must refers to local national codes 12 Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 11 0 W C P...

Страница 6: ...rfaces above 36 914 mm high There must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of...

Страница 7: ...13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 762 mm 457 mm 18 min PROXIMITY TO SIDE CABINETS Fig 1 3b ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as...

Страница 8: ...o be attached as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide ran...

Страница 9: ...cal gas supplier See page from 13 to 16 for L P gas conversion instructions 1 Manual Shut off Valve fig 2 1 A manual shut off valve must be installed in an accessible location in the gas line external...

Страница 10: ...ch Do not over tighten the connector Over tightening may crack regulator STEP 2 Assemble the 1 2 NPT connector pressure regulator group to the extension pipe interposing the gasket supplied The regula...

Страница 11: ...cal male 1 2 NPT female 1 2 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented toward the connector Arrow Extension pipe fe...

Страница 12: ...range can withstand a maximum input pressure of 1 2 PSI 14 0 W C P If the line pressure is in excess of that amount a step down regulator will be required e The appliance its individual shut off valve...

Страница 13: ...ers expressed in hundredths of a millimetre are marked on the body of each injector SETTING THE PRESSURE REGULATOR fig 2 6b The pressure regulator is accessible by removing the bottom drawer the press...

Страница 14: ...ratings the burner covers and the knobs Using a wrench substitute the nozzle injectors J figs 2 7 2 8 with those most suitable for the kind of gas for which it is to be used The burner are conceived i...

Страница 15: ...indicated by the arrow in fig 2 11 and replace it by the proper one according to the kind of gas Then replace the burner repeating the above steps in reverse order b Broil Burner Remove the burner by...

Страница 16: ...one only for the oven burner the broil is a fixed capacity by acting on the thermostat in the following way Turn on the burner by setting the thermostat knob on position Remove the knob and unscrew th...

Страница 17: ...personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong ground type outlet ground...

Страница 18: ...18 WIRING DIAGRAM Fig 3 2...

Страница 19: ...19 19...

Страница 20: ...anscription errors in the present booklet The manufacturer re serves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and withou...

Отзывы: